1 de 1

Omron NX-OD5256-1 NX-series Digital I/O Unit

Omron NX-OD5256-1 NX-series Digital I/O Unit

Apenas 7 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: NX-OD5256-1

  • País de origem:Japão

  • Tipo de Produto: Digital Output Modules

  • Pagamento: T/T, Western Union

  • Peso: 125g

  • Dimensões: 30 mm x 100 mm x 71 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for seamless integration within high-speed Sysmac automation platforms, the NX-OD5256-1 serves as a high-density digital output module featuring 16 transistor outputs. This unit enables precise control over field actuators by delivering reliable switching performance synchronized with the machine controller's execution cycle. Operating on a 24 VDC rated voltage, the module utilizes PNP (source) logic and features built-in load short-circuit protection to safeguard system electronics against field-side electrical faults.

The unit supports advanced synchronization capabilities, allowing for both Free-Run and Synchronous I/O refreshing. Field connections are secured via a rugged, detachable M3 screw terminal block, which facilitates easy installation and maintenance. Designed for mounting on a standard DIN rail, this module connects directly to NX-series Bus Couplers for EtherCAT or EtherNet/IP, making it highly compatible with modern distributed control architectures.

Features

  • Provides 16 digital output points in a compact form factor.
  • Utilizes PNP (source) output logic with a rated voltage of 24 VDC.
  • Features integrated load short-circuit protection for system safety.
  • Supports Synchronous I/O refreshing and Free-Run refreshing modes.
  • Equipped with a detachable M3 screw terminal block for reliable physical wiring.
  • Simplifies configuration and troubleshooting via Sysmac Studio software.

Applications

  • Packaging and labeling machinery control
  • Automated assembly and material handling systems
  • Water treatment and environmental control panels
  • Pneumatic and hydraulic valve manifold actuation
  • General factory automation and distributed I/O systems

Technical Specifications

Parameter Specification
Manufacturer Omron
Part Number/Model NX-OD5256-1
Series NX-series Digital I/O Unit
Output Type Transistor Output (PNP/Source)
Number of Outputs 16 points
Rated Voltage 24 VDC
Maximum Load Current 0.5 A per point
I/O Refreshing Method Free-Run refreshing, Synchronous I/O refreshing
Short-Circuit Protection Yes (Load short-circuit protection)
External Connection Terminals M3 screw terminal block
Dimensions (W x H x D) 30 mm x 100 mm x 71 mm
Weight 0.125 kg

Installation Guidelines

Ensure the following engineering practices are observed during the installation of the module:

  • Mounting: Mount the module securely onto a 35 mm DIN rail inside a protective industrial enclosure. Verify the DIN rail is properly grounded.
  • Wiring: Turn off all power supplies before connecting or disconnecting the M3 screw terminal block to prevent electrical shock or equipment damage.
  • Heat Dissipation: Maintain recommended clearances above and below the NX-series unit stack to ensure natural convection cooling. Do not block the ventilation holes.
  • Shielding and Noise: Route DC control lines separate from high-voltage AC power lines to minimize electromagnetic interference.

Compliance and Certifications

  • CE Mark
  • UL Listed (cULus)
Loading product navigation…

What is the output logic type of the Omron NX-OD5256-1?

The NX-OD5256-1 uses PNP (source) transistor output logic.

What kind of terminal connection does this module use?

The module is equipped with a detachable M3 screw terminal block for secure field wiring.

Does the NX-OD5256-1 support synchronous refreshing?

Yes, it supports both Free-Run refreshing and Synchronous I/O refreshing depending on the NX-series coupler and controller configuration.

What is the maximum output current rating per point?

The maximum load current is 0.5 A per output point.

Does this digital output unit include protection circuits?

Yes, the unit features built-in load short-circuit protection to protect the internal circuitry from fault currents.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Transformaram a Mineração Subterrânea

Desde compressores CC acionados por corda até carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como...