1 de 3

Yokogawa NFAI135-S51 S2 STARDOM-FCN Analog Input Module

Yokogawa NFAI135-S51 S2 STARDOM-FCN Analog Input Module

Apenas 5 item(ns) restante(s) em estoque
  • Fabricante: Yokogawa

  • Nº do Produto: NFAI135-S51 S2

  • País de origem:Japão

  • Tipo de Produto: Analog Input Module

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 300g

  • Dimensões: 3.2cm x 10.6cm x 13cm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

The Yokogawa NFAI135-S51 S2 is an isolated channel analog input module engineered for the STARDOM FCN autonomous controller platform. It features 8 dedicated input channels configured to process 4 to 20 mA DC current signals from 2-wire and 4-wire transmitters. Channel-to-channel isolation delivers robust electrical protection and high signal integrity, effectively mitigating ground loops and field noise in complex industrial processing zones. Equipped with an ISA Standard G3 environmental option, the module is built to withstand corrosive atmosphere variables, making it optimal for long-term reliability in critical process automation frameworks.

Features

  • Channel-to-Channel Isolation: Employs rigorous electrical isolation between the inputs and the system, as well as between individual channels.

  • HART Communication Capability: Supports digital field communication overlaid onto standard 4 to 20 mA hardware loops.

  • ISA Standard G3 Option: Configured with professional environmental protection to counter atmospheric corrosion.

  • Integrated Overcurrent Protection: Protects sensitive internal circuits against unexpected electrical surges from field line paths.

Applications

  • Oil and gas exploration and refining facilities

  • Petrochemical and chemical process plants

  • Municipal water and wastewater management systems

  • Power generation system monitoring

  • Distributed industrial data acquisition networks

Ordering Information

Model Suffix Codes Description
NFAI135 Analog Input Module (4 to 20mA, 8-channel, Isolated channels)
-S Standard type
5 With no explosion protection
1 With ISA Standard G3 option

Technical Specifications

Parameter Specifications
Manufacturer Yokogawa
Model NFAI135
Number of Input Channels 8-channel input, isolated channels
Input Signal 4 to 20 mA
Allowable Input Current 25 mA
Overcurrent Protection Provided
Withstanding Voltage

Between input/output and system: 500 V AC for 1 minute


Between channels: 500 V AC for 1 minute

Input Resistance (Power ON) 250 ohm
Input Resistance (Power OFF) 500 ohm or more
Accuracy +/-0.1% of full scale
Data Refresh Cycle 10 ms
Input Step Response Time 100 ms
Transmitter Power Supply 20.2 to 29.3 V
Temperature Drift Max. +/-0.01%/degC
Maximum Current Consumption 360 mA (5 V DC), 450 mA (24 V DC)
Weight 0.3 kg
External Connection Pressure clamp terminal, MIL connector cable
HART Communication Available

Installation Guidelines

  • Ensure a stable 24 V DC source is linked to the analog field power supply terminal of the power supply module.

  • Form physical terminations using the corresponding pressure clamp terminal block or a tailored MIL connector cable system.

  • Note that when using a MIL connector cable like the KMS40, the withstanding voltage limit between input and system drops to 500 V AC for 1 minute.

  • Avoid coupling Zener barriers to this hardware; specify an isolation barrier for intrinsically safe installation demands.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa NFAI135-S51 S2 STARDOM-FCN Analog Input Module

What does the S2 designation stand for on this module?

The S2 identifier represents Style 2, indicating the specific hardware revision version of the module manufactured by Yokogawa.

Does this module feature channel-to-channel isolation?

Yes, it provides complete channel-to-channel galvanic isolation as well as isolation between the field inputs and the system backend, rated at 500 V AC for 1 minute.

Can I connect a Zener barrier to the input channels?

No, connecting a Zener barrier directly to this module is not allowed. You must use an isolation barrier if implementing it within an intrinsically safe circuit.

What are the configuration constraints indicated by the NFAI135-S51 codes?

The code denotes a standard module type (-S), no explosion protection features (5), and the integration of the ISA Standard G3 conformal coating option (1) for hostile atmospheric environments.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...