1 de 3

Yokogawa SAI143-S33 ProSafe-RS Analog Input Module

Yokogawa SAI143-S33 ProSafe-RS Analog Input Module

Apenas 8 item(ns) restante(s) em estoque
  • Fabricante: Yokogawa

  • Nº do Produto: SAI143-S33

  • País de origem:Japão

  • Tipo de Produto: Analog Input Module

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 340g

  • Dimensões: 32.8 mm x 130 mm x 107.5 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

The Yokogawa SAI143-S33 is a high-reliability current input module designed for mounting on the safety node unit and safety control unit within the ProSafe-RS safety instrumented system. This module plays a critical role in safety functions by inputting 4 to 20 mA signals from field instruments directly into the Safety Control Station (SCS). It supports dual-redundant configurations to achieve enhanced system availability and fault tolerance. The SAI143-S33 features standard individual channel configuration pins for 2-wire or 4-wire transmitters and provides module isolation for its 16 processing channels.

Features

  • Dual Redundancy: Supports full dual-redundant configuration to eliminate single points of failure in safety-critical applications.
  • Flexible Sensor Hookup: Individual channel setting via pins to accommodate both 2-wire and 4-wire field transmitter arrangements.
  • Simultaneous Power Management: Built-in transmitter power supply ON/OFF function across all 16 channels simultaneously, facilitating alarm resets for Fire and Gas devices.
  • Robust Isolation: Delivers module-level galvanic isolation protecting internal system electronics from hazardous field transients.

Applications

  • Safety Instrumented Systems (SIS) 
  • Emergency Shutdown Systems (ESD)
  • Fire and Gas (F&G) System integration and device resetting 
  • Process industry safety monitoring and critical current loop sourcing 

Ordering Information

Model Suffix Codes Description
SAI143   Analog Input Module (4 to 20 mA, 16 channels, module isolation) 
  -S Standard type 
  3 For pressure clamp terminal block or MIL cable with no explosion protection
3 With ISA Standard G3 and temperature (-20 to 70 degC) 

Technical Specifications

Item Specifications
Manufacturer Yokogawa Electric Corporation 
Model SAI143-S33 
Number of Input Channels 16 channels, module isolation 
Rated Input Range 4 to 20 mA 
Permissible Input Range 0 to 25 mA 
Input Impedance (Power-ON) 250 Ohm + Voltage drop in the input protection circuit inside the module / Current value 
Input Impedance (Power-OFF) 500 Ohm minimum 
Maximum Voltage Drop 0.45 V (in the input protection circuit) 
Rated Accuracy ±16 uA (Input range 1 to 23 mA for Style S3) 
Data Update Frequency 40 ms 
Temperature Drift ±16 uA/10 degC 
Transmitter Power Supply 16.15 V minimum (at 20 mA), 26.4 V maximum (at 0 mA) 
Output Current Limit 25 mA 
Withstand Voltage 1.5 kV AC between input signal and system for 1 minute 
Maximum Current Consumption 5 V system: 320 mA, 24 V system: 550 mA 
Ambient Temperature -20 to 70 degC 
Environmental Code ISA Standard G3 
Weight Approx. 0.34 kg (For pressure clamp terminal block or MIL cable) 
Dimensions (W x H x D) 32.8 mm x 130 mm x 107.5 mm (For pressure clamp and MIL cable) 

Installation Guidelines

  • Module Siting: Mount the current input module onto a compatible safety node unit or safety control unit chassis.
  • Redundancy Setup: When implementing dual-redundant pairs, order an additional tracking module with identical technical specifications but without specific optional suffix accessories.
  • Safety Isolation Barriers: Do not connect Zener barriers directly to this hardware. Utilize an approved isolation barrier when deploying an intrinsically safe instrumented loop.
  • False Insertion Prevention: When deploying option /PRP, utilize the specified matching field signaling cable variant equipped with the corresponding option /SAI143 to ensure functional physical key alignment.

Compliance and Certifications

  • ISA Standard G3: Certified for installation within corrosive industrial environments meeting the G3 severity specifications.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa SAI143-S33 ProSafe-RS Analog Input Module

Can Zener barriers be connected directly to the module?

No, Zener barriers cannot be connected to this module. An isolation barrier must be used when an intrinsically safe instrumented system is required.

What is the purpose of the transmitter power supply ON/OFF function?

This function allows the module to turn off the transmitter power supplied to all 16 channels simultaneously under a 2-wire setting, which enables resetting the alarm state of Fire and Gas devices.

How is the 2-wire or 4-wire mode configured on the module?

The 2-wire or 4-wire operational mode is set individually for each channel using dedicated physical setting pins on the module.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...