1 из 6

ABB ACS550-01-08A8-4 ACS550 Variable Frequency Drive

ABB ACS550-01-08A8-4 ACS550 Variable Frequency Drive

Остался только 5 товар(ы) на складе
  • Производитель: ABB

  • Номер продукта: ACS550-01-08A8-4

  • Страна происхождения:Швеция

  • Тип продукта: Variable Frequency Drives

  • Штрихкод: 85044095

  • Оплата: Т/Т, Western Union

  • Вес: 6500г

  • Размеры: 12.50 x 36.90 x 21.20 cm

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Engineered to deliver precise speed and torque control for three-phase induction motors, the ABB ACS550-01-08A8-4 variable frequency drive integrates seamlessly into low-voltage industrial power systems. This highly reliable motor controller supports an output power rating of 4 kW (5 HP) under normal duty conditions and operates across a standard supply voltage range of 380 to 480 V AC. As part of the established ACS550 series, this drive features an integrated swinging choke that significantly lowers harmonic distortion compared to standard line reactors, enhancing the operational lifespan of connected electrical infrastructure. The unit is housed in a robust IP21 protection enclosure, making it ideal for standard wall-mounted industrial installations requiring dependable thermal dissipation and compact spatial footprints.

Features

  • Patented Swinging Choke: Reduces line harmonics up to 25% at partial loads without the bulk of external line reactors.
  • Flexible Control Modes: Supports scalar (V/Hz) and sensorless vector control for adaptable torque profiles.
  • Integrated EMC Filter: Built-in RFI/EMC filter ensures compliance with European and domestic high-frequency interference standards.
  • Native Fieldbus Interface: Standard Modbus RTU interface on RS-485 terminals simplifies integration into distributed SCADA architectures.
  • FlashDrop Compatibility: Enables parameter uploading and drive programming in seconds without applying main power.

Applications

  • Centrifugal pumps requiring energy-efficient flow control and quadratic torque profiles.
  • Industrial supply and exhaust fans utilizing speed-regulated HVAC air distribution.
  • Material handling conveyors demanding controlled acceleration and deceleration ramps to prevent mechanical stress.
  • Mixers, agitators, and dosing systems requiring constant low-speed torque stability.

Technical Specifications Table

Parameter Specification
Manufacturer ABB
Model Number ACS550-01-08A8-4
Series ACS550 Standard Drive
Input Voltage Range 380 to 480 V AC (+10% / -15%)
Number of Phases 3-Phase Input / 3-Phase Output
Normal Duty Output Power 4 kW (5 HP)
Normal Duty Output Current 8.8 A
Heavy Duty Output Power 3 kW (4 HP)
Heavy Duty Output Current 6.9 A
Input Frequency Range 48 to 63 Hz
Enclosure Rating IP21 (UL Type 1)
Control Connections 2 Analog Inputs, 2 Analog Outputs, 6 Digital Inputs, 3 Relay Outputs
Communications Modbus RTU (Embedded)
Product Dimension (W x H x D) 12.50 x 36.90 x 21.20 cm
Net Shipping Weight 6.50 kg
Commodity Code 85044095

Connections and Interfaces

Terminal Designation Function / Assignment
U1, V1, W1 3-Phase AC Power Input Terminals
U2, V2, W2 3-Phase AC Variable Frequency Output to Motor
BRK+, BRK- Dynamic Braking Resistor External Connections
AI1 / AI2 Analog Inputs (Voltage 0...10V / Current 0/4...20mA)
AO1 / AO2 Analog Outputs (Programmable, standard 0/4...20mA)
DI1...DI6 Digital Inputs (Configurable, 12...24V DC PNP/NPN logic)
RO1, RO2, RO3 Relay Outputs (Form C, programmable, max 250V AC / 30V DC)

Alternative Models & Compatibility

The ACS550-01-08A8-4 directly replaces legacy Frame R1 ACS400 drives with minimal mechanical adaptation. When retrofitting, note that digital I/O macros may default to "ABB Standard"; ensure your existing control wire maps match the programmed macro. For network upgrades, this VFD is fully compatible with optional fieldbus modules including the RPBA-01 (Profibus-DP), RCAN-08 (CANopen), and RETA-01 (EtherNet/IP / Modbus TCP).

Application Pitfalls & Engineering Notes

For high-elevation installations exceeding 1000 meters above sea level, the output current must be derated by 1% for every additional 100 meters. Additionally, when using motor cables longer than 100 meters (328 feet), parasitic capacitance to earth can cause false "F0016" (Earth Fault) trips. In these configurations, an external du/dt filter or output reactor must be installed to protect the drive's output IGBT bridge and prevent winding degradation on older motors.

Commissioning & Wiring Tips

To configure analog input signals, ensure the onboard DIP switches (located behind the Assistant Control Panel assembly on the control board) match the desired input signal type: Switch J1 controls AI1 (Voltage/Current) and Switch J2 controls AI2 (Voltage/Current). Ensure control wiring is run in separate conduits from high-power motor and input cables to prevent high-frequency noise coupling. Always ground the motor cable shield 360 degrees at both the VFD clamp and the motor terminal box.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Before beginning any installation, maintenance, or terminal wiring, disconnect all input power sources and lock out all disconnects. Wait a minimum of 5 minutes after de-energizing the drive to allow the internal DC bus capacitors to discharge fully. Verify zero voltage across terminals U1/V1/W1 and the DC bus terminals prior to handling internal components.

1

Mount the drive vertically on a flat, non-flammable surface, ensuring at least 200 mm of clearance above and below the cooling fan assembly for unimpeded vertical airflow.

2

Connect the input power conductors to terminals U1, V1, and W1, and the protective earth (PE) grounding conductor to the drive's primary chassis ground terminal.

3

Terminate the motor cables to U2, V2, and W2 using symmetrically shielded motor cables to minimize electromagnetic radiation and bearing currents.

4

Wire control, interlock, and emergency stop circuits to the I/O terminals, separating them by at least 200 mm from the high-voltage power lines.

Loading product navigation…

What does the 'F0016' earth fault indicate on this VFD?

An F0016 fault indicates an asymmetrical earth/ground leakage current in the motor or motor cable. Check the insulation resistance of both the motor windings and the motor cabling using a megohmmeter after disconnecting the drive completely.

Can this drive run on single-phase utility power?

This model is rated for three-phase input power. Operating it on a single-phase supply is not recommended unless substantial current derating (typically 50%) is applied, and parameter 3007 (Input Phase Loss) is configured to prevent automatic tripping.

How do I switch the analog input signals between voltage and current modes?

Locate the J1 jumper block on the control board directly below the keypad mounting cradle. Change the jumper placement for AI1 or AI2 to 'I' for 0/4-20mA current loops, or 'V' for 0-10V voltage signals, and align parameter 1301/1304 accordingly.

What is the function of the built-in swinging choke?

The swinging choke matches drive inductance to the load state. It reduces input line current harmonics up to 25% under partial load conditions and improves the line voltage THD (Total Harmonic Distortion) profile compared to standard input reactors.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Швеция

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...