1 из 6

ABB S200-RPA 490176212 Advant S200 I/O Repeater Adapter Module

ABB S200-RPA 490176212 Advant S200 I/O Repeater Adapter Module

Остался только 5 товар(ы) на складе
  • Производитель: ABB

  • Номер продукта: S200-RPA

  • Страна происхождения:Швеция

  • Тип продукта: Repeater Adapter Modules

  • Штрихкод: 85371091

  • Оплата: Т/Т, Western Union

  • Вес: 620г

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Serving as a fundamental power distribution and communication interface, the ABB S200-RPA manages backplane voltage and signal translation within distributed Advant S200 I/O architectures. This high-efficiency interface module accepts an external 24V DC (Class 2) input supply and converts it to a clean, regulated 5V DC output rated at 1.6A to drive the internal logic of connected downstream I/O modules. Simultaneously acting as an active signal repeater, the S200-RPA ensures signal integrity across extended physical distances and multi-node clusters on the local S200 I/O bus, maintaining deterministic communication even in electrically challenging industrial environments.

Features

  • Dual-Function Topology: Combines active logic-level signal repeating with integrated 24V to 5V DC step-down power regulation.
  • Regulated Backplane Output: Delivers a highly stable 5V DC supply at up to 1.6A to drive internal communication circuits.
  • Class 2 Circuit Compatibility: Rated for a maximum input capacity of 24V DC at 7A, aligning with standard safety and power-limiting requirements.
  • Galvanic Isolation: Provides robust isolation to protect downstream distributed I/O modules from input-side voltage transients.
  • DIN-Rail Mounting: Designed for rapid, standardized installation into high-density control cabinets.

Applications

  • Advant OCS (Open Control System) distributed I/O architectures.
  • Power segmentation and bus expansion in complex, multi-rack S200 I/O configurations.
  • Heavy industrial automation environments requiring high noise immunity and isolation.

Technical Specifications

Parameter Specification Value
Manufacturer ABB
Model Designation S200-RPA
Article Number / SKU 490176212
Product Series Advant S200 I/O
Primary Input Voltage 24V DC (Class 2 compatible)
Maximum Input Current 7A
Backplane Output Voltage 5V DC (regulated)
Maximum Output Current 1.6A
Product Lifecycle Status Phase-Out (Legacy / Spare Parts Support Active)
Net Weight 0.62 kg
Commodity Code (HS Code) 85371091

Empirical Engineering Insights

Alternative Models & Compatibility

As the Advant S200 I/O system is currently in its Phase-Out stage, sourcing exact-match hardware like the S200-RPA (490176212) is vital for keeping legacy control networks running without rewriting system configurations. This module functions as a critical bridge. When configuring system hardware, always ensure compatibility with downstream processing modules (e.g., the AC input module S200-IA8) to prevent firmware and communication protocol discrepancies on the S200 I/O bus.

Application Pitfalls & Engineering Notes

A common issue in larger distributed clusters is overloading the 5V DC bus. While the S200-RPA can handle up to 7A on the 24V DC input side, its regulated backplane logic output is strictly capped at 1.6A. Before commissioning, calculate the combined current draw of all downstream modules connected to the same bus segment. If the cumulative consumption exceeds 1.6A, you must break the segment and add a second S200-RPA to boost and isolate the backplane logic supply.

Commissioning & Wiring Tips

To guarantee optimal performance and shield the signal bus from electromagnetic interference (EMI), ensure that the DIN rail itself is connected to a low-impedance functional earth. The integrated shield grounding spring on the rear of the S200-RPA relies on direct, clean contact with an unpainted DIN rail. When wiring the primary 24V DC input, always employ an isolated Class 2 power supply to remain within safety certifications and protect internal components from source transients.

Installation Guidelines

CRITICAL WARNING: De-energize all primary 24V DC power supply lines before attempting installation, mounting, or wiring of this equipment. Do not hot-swap or insert/remove this adapter module under electrical load, as doing so can trigger immediate communication failures or damage internal logic circuits.
1
Mounting onto DIN Rail: Securely snap the S200-RPA module onto a grounded, unpainted standard DIN rail, verifying that the rear grounding contacts are firmly engaged.
2
Wire the 24V DC Supply: Connect the positive and negative leads of a verified Class 2 24V DC supply to the input power terminals. Ensure the wires are securely tightened to avoid localized thermal hotspots.
3
Assemble Downstream Modules: Physically slide the adjacent Advant S200 I/O modules into position onto the right-hand bus interface. Secure all locking mechanisms before applying power.
Loading product navigation…

What is the primary function of the S200-RPA module?

The S200-RPA functions as both an active bus repeater and a step-down power adapter, converting an external 24V DC Class 2 supply down to a regulated 5V DC output to power the internal logic backplane of connected Advant S200 I/O modules.

What happens if the downstream current load exceeds the 1.6A specification?

The module cannot supply more than 1.6A at 5V DC. If your I/O module configuration exceeds this draw, you must partition the bus and install an additional repeater module to supply isolated power to the remaining segments.

Is the S200-RPA designed for hot-swapping during system operation?

No. The system and its associated I/O power supplies must be completely de-energized before mounting, wiring, or removing the adapter module to prevent communication disruptions, electrical shock, or damage to downstream logic circuits.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Швеция

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...