The ABB PSTX840-600-70 (product ID 1SFA898119R7000 / 1SFA 8981 19 R7000) is a three-phase PSTX series softstarter engineered for controlled starting, stopping, and protection of medium- to large-sized three-phase AC induction motors. Operating across a main circuit voltage range of 208 to 600 V AC at 50/60 Hz with a 100 to 250 V AC control supply, the unit delivers a rated operational current of 840 A in an in-line connection (250 kW at 230 V, 450 kW at 400 V, and 600 kW at 500 V) or 1455 A in an inside-delta connection (450 kW at 230 V, 800 kW at 400 V, and 1000 kW at 500 V).
Equipped with three-phase voltage-ramp and torque-control algorithms, the PSTX840-600-70 integrates a built-in bypass contactor to minimize power losses during continuous running and simplify panel wiring. Operators interact via a detachable full-graphic display rated IP66 and UL Type 4X for outdoor panel mounting, while system integration is supported through hardwired Start/Stop/Reset inputs, three programmable digital inputs, four signaling relays, an analog output (0 to 10 V, 0 to 20 mA, or 4 to 20 mA), built-in Modbus RTU, and optional Anybus communication modules.
Features
Three-phase motor control supporting soft start and soft stop via voltage ramp or torque control
Built-in bypass for reduced heat dissipation, energy savings, and simplified cabinet installation
High current capacity rated at 840 A in-line and 1455 A inside-delta with a starting capacity of 4 x Ie for 10 seconds
Detachable full-graphic HMI display with IP66 and UL Type 4X outdoor environmental rating
Built-in electronic overload protection (EOL) with dual overload curves for start and run phases
Advanced motor control modes including kickstart, forward/reverse slow-speed jog, dynamic braking, standstill brake, pump cleaning, motor heating, sequence start, emergency/fire pump mode, and two-phase limp mode
Comprehensive electrical and thermal protection covering phase reversal, current/voltage imbalance, underload, locked rotor, ground fault, thyristor overload, and PTC/PT-100 temperature inputs
Built-in Modbus RTU communication plus support for optional Anybus modules (Profinet, Profibus, Modbus TCP, EtherNet/IP, EtherCAT, DeviceNet, CANopen, BACnet-IP, and BACnet-MSTP)
Four integrated status signaling relays (Run, By-pass/TOR, Fault, Overload) and configurable analog output (0 to 10 V, 0 to 20 mA, 4 to 20 mA)
Applications
Centrifugal and positive-displacement pumps, including municipal water systems and emergency/fire pump installations
Industrial ventilation fans, exhaust blowers, and HVAC air handling units
Rotary screw, reciprocating, and centrifugal air and gas compressors
Heavy-duty belt conveyors, crushers, and bulk material handling systems
High-inertia three-phase industrial machinery operating on 208 to 600 V AC mains
Detachable full-graphic display (IP66 and UL Type 4X outdoor rating)
Main Circuit Terminal Type
Busbars (Bars)
Tightening Torque (Main Circuit)
45 N-m (398.3 lb-in UL/CSA)
Connecting Capacity (Control & Supply Circuits)
Rigid 1 x 2.5 mm2
Degree of Protection
Main Terminals: IP00 (IEC 60529, IEC 60947-1, EN 60529); Graphic Display: IP66 / Type 4X
Ambient Operating Temperature
-25 to +60 degC
Ambient Storage Temperature
-40 to +70 degC
Dimensions (W x H x D)
435 mm x 493 mm x 369 mm
Net Weight
46.5 kg
Shipping Package Dimensions & Gross Weight
600 mm (W) x 616 mm (D) x 800 mm (H); 58.5 kg gross weight
Customs Tariff Number
85371091
Connections/Interfaces
Connector Pin
Function
Main Power Busbars
Three-phase line and motor load busbar connections rated up to 840 A in-line (1455 A inside-delta), tightened to 45 N-m
Control Supply Terminals (Us)
100 to 250 V AC (50/60 Hz) auxiliary control power input accepting rigid 1 x 2.5 mm2 conductors
Control Circuit & Digital Inputs (Uc)
24 V DC control circuit with hardwired Start, Stop, Fault Reset, and three programmable digital inputs (rigid 1 x 2.5 mm2)
Signal Output Relays
Normally Open (NO) relay outputs for Run, By-pass / Top of Ramp (TOR), Fault, and Overload status indication
Analog Output Terminals
Configurable analog feedback output supporting 0 to 10 V, 0 to 20 mA, or 4 to 20 mA signals
Temperature Sensor Inputs
Dedicated motor thermal protection inputs supporting PTC and PT-100 sensors
Built-in Fieldbus Interface
Integrated Modbus RTU serial communication interface and external Fieldbus plug adaptor support (PS-FBPA)
Anybus & HMI Expansion Ports
Front expansion slot for optional Anybus industrial Ethernet/fieldbus modules and port for the detachable IP66 graphic display or PSCA-1 USB cable
Installation Guidelines
Enclosure Protection: Because the main power terminals carry an IP00 protection rating, install the softstarter inside a suitable industrial control enclosure; optionally fit terminal shrouds (LT750-AC / LT750-AL) and terminal enlargements (LW750) or CuAl cable lug kits (1SDA013956R1 / 1SDA023380R1) for finger protection and conductor termination.
Busbar & Control Wiring Torque: Tighten main circuit busbar connections to 45 N-m (398.3 lb-in per UL/CSA specifications) and terminate control/supply wiring using rigid 1 x 2.5 mm2 conductors.
Connection Configuration: Select between standard in-line connection (up to 840 A) and inside-delta connection (up to 1455 A) using the integrated inside-delta configuration switch prior to commissioning.
Remote HMI Mounting: Detach the IP66 / Type 4X rated graphic display from the softstarter body and mount it on the cabinet door for external operator access and diagnostics without opening the enclosure.
Thermal Clearance & Operating Environment: Maintain ambient air temperatures within -25 to +60 degC inside the panel during operation.
Compliance and Certifications
CE: Compliant with European Union directives (Declaration of Conformity 2CMT005209)
UL / cULus: Rated for UL/CSA three-phase motor control up to 600 V AC and 800 Hp
CCC and CQC: Certified under China Compulsory Certification (2020980304001095 / 2020980304001491) and CQC (CQC2015010304830300 / CQC2015010304830295)
DNV: Marine and offshore type approval certificate TAE000087N
RoHS and REACH: Compliant with EU RoHS Directive 2011/65/EU and Amendment 2015/863 (2CMT2022-006500), EU REACH (2CMT2022-006481), and US TSCA (2CMT2023-006524)
Environmental & Data Compliance: ABB EcoSolutions validated with 81.9% recyclability per EN 45555, WEEE Category 5 B2B compliance, and EU Data Act compliance (1SFC132498M0201)
FAQ
What are the current and power ratings for the ABB PSTX840-600-70 softstarter?
The ABB PSTX840-600-70 (1SFA898119R7000) is rated for 840 A in an in-line connection (250 kW at 230 V, 450 kW at 400 V, 600 kW at 500 V) and up to 1455 A in an inside-delta connection (450 kW at 230 V, 800 kW at 400 V, 1000 kW at 500 V).
Does the PSTX840-600-70 include a built-in bypass and electronic overload protection?
Yes, the softstarter features an integrated bypass contactor to reduce running energy losses along with built-in dual electronic overload protection (EOL) for both start and run phases.
What communication protocols and control voltages are supported by 1SFA898119R7000?
It operates on a 100 to 250 V AC (50/60 Hz) control supply with a 24 V DC control circuit, includes built-in Modbus RTU, and supports Anybus modules for Profinet, Profibus, Modbus TCP, EtherNet/IP, EtherCAT, DeviceNet, CANopen, and BACnet.
Can the graphic display on the PSTX840-600-70 be mounted on a panel door?
Yes, the softstarter includes a detachable full-graphic display rated IP66 and UL Type 4X for outdoor and cabinet door mounting.
Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
Экспресс-отправка: Отправка в тот же день для заказов со склада, оформленных до 14:00 (GMT+8).
Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.
Возвраты и гарантия
30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.
Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).
Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным
Политика возврата и возмещения
.
Инженерный контрольный список для замены Allen-Bradley 1746-A7: проверьте серию шасси, нагрузку на объединительную плату, план размещения модулей в слотах, соединительные кабели, монтаж, заземление и...
Руководство по замене на месте GE Fanuc IC200MDL650: логика с отрицательной полярностью в зависимости от ревизии, четыре распространённые группы, пороговые значения для 24 В постоянного тока,...
Практическое руководство по замене IC697CPX935: быстрая память, особенности работы последовательного интерфейса в зависимости от прошивки, питание стойки, охлаждение, архитектура ввода-вывода и...
Практическое руководство по замене IC693DSM324: проверка контроллера Series 90-30, записи о цепочке сервоприводов FSSB, расчёт бюджета питания 5 В, ограничения прошивки, управление ведомым...
Практическое руководство по замене HIMA F3430: номинальные параметры контактов реле, снижение допустимой нагрузки постоянного тока, защита предохранителями, различия между F3330 и F3331, ограничения...
Практическое руководство по замене IC697PWR710: расчёт нагрузки 5 В, ограничения для двух стоек, удлинительные кабели, проверки входных параметров, работа защиты и риски, связанные с ревизией...
Выбор варианта приводит к полной перезагрузке страницы.