1 из 1

Beckhoff CX2550-0279 CX2000 Series USB Extender 2.0 Transmitter Module

Beckhoff CX2550-0279 CX2000 Series USB Extender 2.0 Transmitter Module

Остался в наличии только 10 товар(ы)
  • Производитель: BECKHOFF

  • Номер продукта: CX2550-0279

  • Страна происхождения:Германия

  • Тип продукта: USB Extender Modules

  • Оплата: Т/Т, Western Union

  • Вес: 500г

  • Размеры: 24 mm x 99 mm x 54.5 mm

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

The Beckhoff CX2550-0279 functions as a direct system-bus expansion module designed for CX20xx Embedded PCs, enabling remote USB 2.0 signal transmission up to 50 meters. This transmitter module mounts directly to the left-hand side of a CX20xx CPU block, converting standard internal USB lines into a serialized differential signal suitable for long-distance runs over standard Ethernet-style physical media. This setup is specifically optimized for connecting control panels such as the CP29xx-0000 series without signal degradation or latency spikes, ensuring seamless peripheral integration in complex industrial environments.

Key Features

  • Dedicated 1 x USB Extended 2.0 interface utilizing a rugged RJ45 connection port.
  • Reliable signal extension up to a maximum distance of 50 meters over standard Cat.5E or higher shielded cabling.
  • Native system bus integration drawing power directly through preceding CX2100-0xxx power supply units.
  • On-board LED diagnostic indicators for real-time status validation (Power, Host, Activity, and Link status).
  • Compact 24 mm form factor designed for high-density DIN-rail mounting configurations.

Applications

  • Connecting decentralized HMI and operator screens (CP29xx-0000 series) in scattered manufacturing cells.
  • Extending USB diagnostic interfaces outside enclosed, high-voltage electrical panels.
  • Facilitating clean wiring routing in modern modular production lines and material handling facilities.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Number CX2550-0279
Interface Type 1 x USB Extended 2.0 (via RJ45 socket)
Maximum Cable Length 50 meters (using Cat.5E cabling)
Power Feed Via system bus (through CX2100-0xxx modules)
LED Diagnostics Power (1x), Host (1x), Activity (1x), Link (1x)
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Weight Approximately 190 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Port Type Connector Pinout / LED Signal Description
RJ45 Output Port Pins 1 to 8 Differential USB transmission pairs over Cat.5E shielded line. Do not connect to Ethernet switches.
LED: PWR On (Green) Internal system power is successfully applied via the system bus.
LED: HOST On (Green) Established connection with the primary CX20xx CPU host interface.
LED: LINK On (Green) Active connection established with the remote CP29xx receiver.

Empirical Engineering Insights

Alternative Models & Compatibility

This module behaves specifically as a Point-to-Point Transmitter (Tx) and must be paired with an appropriate receiver, typically integrated directly into Beckhoff CP29xx-0000 Control Panels or external receiver boxes. It is physically designed to slide and snap into place on the left-side expansion slot of the CX20xx series. Ensure your CPU configuration in TwinCAT recognizes the additional module on the PC-system bus before commissioning.

Application Pitfalls & Engineering Notes

A common error on-site is treating the physical RJ45 interface on the front of this unit as an Ethernet network port. Patching this connection into a standard LAN switch, router, or hub can cause immediate electrical damage to either the network hardware or the internal transceiver circuitry of the controller. Keep the extension path strictly point-to-point.

Commissioning & Wiring Tips

For transmissions reaching near the 50-meter limit, always use high-quality, double-shielded copper cabling (S/FTP Cat.5E or Cat.6). Avoid routing this physical-layer run in close proximity to high-frequency variable frequency drive (VFD) output cables or high-voltage lines, as noise coupling on the differential lines can cause momentary dropouts in panel mouse/keyboard and touch signals.

Installation Guidelines

CRITICAL WARNING: Prior to snapping this expansion unit onto the CX20xx CPU module or altering any interface cables, ensure the entire controller rack and any connected remote displays are completely powered down. Verify that no residual voltages are present in the power supply line. Failure to de-energize can damage sensitive differential transceiver chips on the system bus.
1
Align the male multi-pin system-bus connector of the CX2550-0279 with the left-side female interface of the CX20xx CPU unit. Ensure the DIN-rail locking clips are pulled out.
2
Press the module firmly into place until you hear it click, securing it to the adjacent CPU module. Push the DIN-rail locking clips back in to anchor the module on the DIN rail.
3
Insert your dedicated Cat.5E shielded line into the front RJ45 socket and route directly to the panel receiver module, keeping it separate from high-interference power lines.
Loading product navigation…

Can I connect this transmitter directly to a standard network switch or router?

No. The RJ45 interface uses a specialized proprietary physical layer to transmit differential USB signals. Connecting this port to an Ethernet switch or network device can damage the internal components of both units.

What is the maximum cable length supported by this module?

The module supports point-to-point connections up to a maximum distance of 50 meters. To reach this distance, use high-quality shielded Cat.5E or Cat.6 cabling.

Where does this module receive its operating power?

The device draws its power directly from the system bus connected to the adjacent CPU block, which is powered through standard CX2100-0xxx power supply units.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...