1 из 1

Beckhoff CX5020-0115 CX Series Embedded PC CPU Module

Beckhoff CX5020-0115 CX Series Embedded PC CPU Module

Остался в наличии только 10 товар(ы)
  • Производитель: BECKHOFF

  • Номер продукта: CX5020-0115

  • Страна происхождения:Германия

  • Тип продукта: PLC CPU Modules

  • Оплата: Т/Т, Western Union

  • Вес: 500г

  • Размеры: 106 mm x 100 mm x 92 mm

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Designed to execute demanding PLC, Motion Control, and industrial visualization tasks, the Beckhoff CX5020-0115 is a high-performance Embedded PC CPU module incorporating an Intel Atom Z530 processor operating at a 1.6 GHz clock frequency. This industrial-grade controller features direct hardware-level backplane support for both E-bus (EtherCAT) and K-bus (Standard Bus Terminals), automatically detecting the system architecture to establish immediate bus communication. Housed in a rugged, fanless IP20 enclosure, the unit integrates a 1-second hardware UPS to secure critical system variables to flash storage during sudden power degradation.

Features

  • High-Efficiency Processing: Single-core Intel Atom Z530 1.6 GHz processor provides predictable execution cycles for TwinCAT applications.
  • Dual Bus Auto-Detection: Supports seamless plug-and-play integration of E-bus and K-bus I/O modules directly on the right side.
  • Integrated Hardware UPS: Provides 1-second UPS backup to preserve 1 MB of persistent data on the Compact Flash card.
  • Versatile Media & Data Ports: Equipped with dual independent Gigabit Ethernet ports, a digital DVI-D output, and four USB 2.0 interfaces.
  • Industrial-Grade Design: Fanless, compact construction with high vibration and shock immunity designed for harsh cabinet environments.

Applications

  • High-speed packaging, sorting, and material handling systems.
  • Distributed wind power generation and grid synchronization units.
  • Multi-axis coordinated motion control and robotic assembly lines.
  • Decentralized process automation and field-level industrial communication gateways.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model Number CX5020-0115
Processor Intel Atom Z530, 1.6 GHz (Single Core)
Main Memory 512 MB RAM (factory standard)
Flash Memory Compact Flash slot (128 MB CF card included)
Persistent Memory Integrated 1-second UPS (1 MB on CF card)
I/O Connections E-bus or K-bus (automatic recognition)
Current Supply (Bus) 2 A
Power Supply 24 V DC (-15 % / +20 %)
Max Power Consumption 13 W
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
TwinCAT Platform Level Performance (40)
Protection Class IP20
Dimensions (W x H x D) 106 mm x 100 mm x 92 mm
Net Weight 575 g
Shipping Weight (Calculated) 3.0 kg
Country of Origin Germany

Connections and Interfaces

Interface Connection Physical Type Function Assignment
Ethernet (LAN 1 / LAN 2) 2 x RJ45 10/100/1000 Mbit/s Network/EtherCAT Interface
Video Display 1 x DVI-D Digital Video Connection for local HMI/Display
USB Ports 4 x USB 2.0 Type A Connection for peripherals, keypads, and flash drives
Power Connector Plug-in terminal block 24 V DC main input and status feedback wiring

Alternative Models & Compatibility

The CX5020-0115 can act as an upgrade pathway for older CX1010 and CX1020 CPU variants. However, system engineers must verify operating system and TwinCAT system environment configuration constraints: compiling a TwinCAT 2 runtime platform requires matching PLC library alignments, whereas importing projects into TwinCAT 3 (XAR) on the Performance Level 40 platform requires target system reassignment within the TwinCAT System Manager.

Application Pitfalls & Engineering Notes

To protect the long-term functionality of the integrated 1-second UPS, ensure that the power supply does not rapidly cycle during commissioning phases. Rapid interruption sequences prevent the UPS capacitors from fully recharging, which can block the execution of critical retentive-data write operations. Maintain clean airflow channels above and below the DIN rail to support natural convection cooling; restricted thermal pathways inside tight enclosures can lead to CPU throttling under elevated processing loads.

Commissioning & Wiring Tips

Use dedicated shielded Cat.6 network cabling to connect EtherCAT devices to the RJ45 gigabit ports to limit electromagnetic coupling from high-power field drives. Connect a low-impedance ground conductor directly from the module's DIN rail to the cabinet ground plate. This establishes a clean reference plane for the internal filter circuits and shields communication on the high-speed E-bus backplane.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out the 24 V DC main control supply before attempting to slide the CPU module onto the DIN rail or attaching K-bus/E-bus terminals. Live insertion or extraction of modules can cause catastrophic arc damage to the slide contacts, leading to corrupted data communication or complete component failure.

1

Position the rear mounting track of the CPU module against the standard TS35 DIN rail, checking that the top and bottom latch components align with the rail edges.

2

Press the module firmly down until the spring-loaded bottom latches snap over the rail, ensuring a stable physical lock.

3

Carefully slide the subsequent E-bus or K-bus industrial I/O terminals alongside the module's right side, ensuring the lateral slide contacts click cleanly into place.

Does the CX5020-0115 support both E-bus and K-bus terminals?

Yes, the module automatically detects whether K-bus (legacy bus terminals) or E-bus (EtherCAT terminals) are connected to its right-side interface and configures communication accordingly.

How does the integrated 1-second UPS function on this CPU module?

The integrated 1-second UPS uses built-in capacitors to provide power long enough to write up to 1 MB of persistent data from the RAM to the Compact Flash card during an unexpected power interruption.

Can the 512 MB main memory be upgraded in the field?

No. The main memory is ex-factory configured and soldered. Any memory upgrades (up to 1 GB) must be ordered directly from the factory prior to delivery.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...