Description

Designed for direct connection of serial devices to EtherCAT networks without an electrical cabinet, the Beckhoff ER6001-0002 serial interface module provides a highly ruggedized, IP67-rated solution for industrial field installations. This module enables the seamless integration of devices featuring RS232, RS422, or RS485 interfaces directly into the EtherCAT communication ring. The interface type is individually selectable per channel, allowing versatile configuration based on system requirements.

Equipped with an integrated 5 V DC sensor supply and auxiliary digital inputs and outputs, the ER6001-0002 serves as an all-in-one local connection point. Its heavy-duty zinc die-cast housing ensures superior resistance to mechanical stress, moisture, and electromagnetic interference, making it an ideal choice for decentralised control environments across heavy industries.

Features

  • Individually selectable serial interfaces: RS232, RS485, or RS422.
  • Robust 864-byte receive buffer and 128-byte transmit buffer to prevent data loss.
  • Two auxiliary 24 V DC digital inputs and two short-circuit proof digital outputs.
  • Dedicated +5 V DC, 1 A sensor power supply.
  • Standardised M12 connection technology for secure sensor and serial device coupling.
  • Integrated M8 EtherCAT bus interfaces with shielded, screw-type connection.
  • Fully encapsulated housing featuring IP65, IP66, and IP67 protection ratings.

Applications

  • Direct machine-level integration of barcode scanners, printers, and weight indicators.
  • Oil and gas field instrumentation and distributed telemetry systems.
  • Power generation and substation auxiliary device communication.
  • Water and wastewater plant field monitoring and control.

Technical Specifications

ManufacturerPart Number / ModelProduct SeriesProtocolSelectable InterfacesData Transfer RatesCommunication ModeData BufferSensor SupplyDigital InputsDigital OutputsBus InterfaceConnection MethodNominal VoltageCurrent ConsumptionElectrical IsolationOperating TemperatureStorage TemperatureProtection RatingWeight
Beckhoff
ER6001-0002
EtherCAT Box
EtherCAT
RS232, RS485, RS422
300 to 115,200 baud (9600 baud preset, 8N1)
TxD and RxD, full duplex
864 bytes receive buffer, 128 bytes transmit buffer
+5 V DC, 1 A
2 x digital inputs, 24 V DC (10 us filter, 11...30 V "1" signal)
2 x digital outputs, 24 V DC (0.5 A per channel, short-circuit proof)
2 x M8 socket, shielded, screw type
M12 x 1, 5-pin, A-coded
24 V DC (-15% / +20%)
Typically 130 mA + load
500 V
-25 to +60 degC
-40 to +85 degC
IP65, IP66, IP67 (conforms to EN 60529)
Approx. 265 g

Connections and Interfaces

Interface Connection Connector Standard Functional Assignment
EtherCAT Bus Input/Output 2 x M8 Socket, Shielded EtherCAT fieldbus ring communication
Serial & I/O Connections M12 x 1, 5-pin, A-coded Serial transmit/receive data, auxiliary inputs, outputs, and sensor power
Power Supply Feed 1 x M8 Male Socket, 4-pin Control (US) and load voltage (UP) feed
Power Supply Downstream 1 x M8 Female Socket, 4-pin Downstream loop connection for power distribution

Installation Guidelines

  • Mount the module directly to the machine frame or mounting plate. No protective enclosure or cabinet is required thanks to the IP67 housing rating.
  • Ensure all M8 and M12 connectors are securely tightened to the specified torque to maintain the integrity of the environmental seal.
  • Use shielded cabling for all serial communication lines (RS232/RS422/RS485) and ensure the shield is properly terminated at the connector.
  • Keep total serial cable lengths within safe limits: maximum 15 m for RS232 connections, and up to 1000 m for RS422/RS485 networks.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27
Loading product navigation…

Which serial communication standards are supported by the ER6001-0002?

The Beckhoff ER6001-0002 supports RS232, RS422, and RS485 communication. The protocol is individually selectable depending on the connected end device.

What is the protection rating of this module?

The module has an IP65, IP66, and IP67 protection rating according to EN 60529, allowing it to be installed directly on machines without requiring a control cabinet.

What type of sensor supply does the module provide?

The module features an integrated +5 V DC sensor supply rated up to 1 A, which can power connected serial devices and sensors directly.

Are there digital inputs and outputs on the ER6001-0002?

Yes, the module includes 2 digital 24 V DC inputs with a 10 us input filter and 2 short-circuit proof digital 24 V DC outputs rated up to 0.5 A per channel.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Электрические приводы для замены жидкостей: практическое руководство

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...