Description

Decentralized signal processing in harsh industrial environments requires robust, field-mountable input/output modules that eliminate the need for protective control cabinets. The IP5109-B318 Fieldbus Box provides a direct connection to PROFIBUS DP networks, permitting reliable high-speed data transmission directly on the machinery. Designed with integrated M12 bus interfaces and M8 power connections, this module enables rapid installation and seamless integration into existing control architectures. Configuration of the device can be executed directly through the master controller or via the specialized KS2000 software suite, which fully supports DP-V1 extensions for parameterized operation.

Features

  • Automatic Baud Rate Detection: Automatically adjusts and synchronizes to network transfer speeds up to 12 Mbaud.
  • Integrated T-Connector: Features a dual M12 interface (plug and socket) minimizing additional network cabling and external splitting hardware.
  • Rugged Environmental Protection: IP65, IP66, and IP67 ingress protection ratings allow mounting directly on equipment without an enclosure.
  • Flexible Parameterization: Supports standard DP-V1 acyclic communication and configuration through KS2000.
  • Power Pass-Through: M8 power connectors allow daisy-chaining control and load voltages to downstream modules, reducing wiring complexity.

Applications

  • Automotive assembly lines and conveyor systems
  • Material handling and sorting systems
  • Food processing and packaging machinery
  • Wastewater treatment facility distributed automation

Technical Specifications

Manufacturer BECKHOFF
Part Number IP5109-B318
Protocol / Fieldbus PROFIBUS DP, DP-V1
Data Transfer Rates Up to 12 Mbaud (automatic detection)
Bus Interface Connection 1 x M12 socket (5-pin, B-coded), 1 x M12 plug (5-pin, B-coded, integrated T-connector)
Data Transfer Medium Shielded copper cable, 2 x 0.25 square millimeters
Control Voltage Power Supply 24 V DC (-15% / +20%)
Load Voltage Power Supply Determined by I/O type
Power Connections Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current Consumption 85 mA + sensor current consumption (maximum 0.5 A)
Electrical Isolation Control voltage/fieldbus: No; Control voltage/inputs-outputs: Dependent on I/O type
Data Transfer Cycle Time Approximately 0.5 ms with 10 stations (each 32-bit input/output)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Shipping Weight 2.0 kg

Connections and Interfaces

Interface Type Connector Style Pin Count & Coding
Fieldbus Input (Bus In) M12 Plug 5-pin, B-coded
Fieldbus Output (Bus Out) M12 Socket 5-pin, B-coded (integrated tee)
Power Supply Feed M8 Male 4-pin
Power Supply Downstream M8 Female 4-pin

Installation Guidelines

Ensure that the mounting surface is clean and flat to maintain the unit's ingress protection. Secure the module using the integrated mounting holes. When routing cables, avoid sharp bends and keep signal cables separate from high-power load lines to prevent electromagnetic interference. All unused M12 and M8 connection ports must be sealed using certified protective caps to maintain the IP65/66/67 environmental rating. Properly ground the fieldbus shield according to standard Profibus installation recommendations.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What configuration tools are compatible with the IP5109-B318?

The module can be configured directly through your primary master controller or using Beckhoff's KS2000 configuration software via the DP-V1 extensions.

Does the IP5109-B318 require a separate Profibus T-connector?

No, the module features an integrated T-connector design using one B-coded M12 socket and one B-coded M12 plug, allowing direct loop-through of the fieldbus line.

How do you maintain the IP67 protection rating when some ports are unused?

To preserve the IP65/66/67 rating, all unused M12 and M8 connector sockets must be fitted with certified protective screw caps.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...