1 из 1

Beckhoff KM1004-0001 Bus Terminal Module 32-Channel Digital Input

Beckhoff KM1004-0001 Bus Terminal Module 32-Channel Digital Input

Остался в наличии только 10 товар(ы)
  • Производитель: BECKHOFF

  • Номер продукта: KM1004-0001

  • Страна происхождения:Германия

  • Тип продукта: Bus Terminal Modules

  • Оплата: Т/Т, Western Union

  • Вес: 2000г

  • Размеры: 75 mm x 100 mm x 55 mm

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Optimizing high-density discrete sensing layouts, the Beckhoff KM1004-0001 integrates 32 digital input channels within a single pluggable bus terminal interface. This compact module acts as an electrical isolator, routing 24 V DC field control signals from proximity sensors, switches, and limit contacts to the central K-bus processing image. By utilizing a 1-wire connection technology with a modular plug-in design, the Beckhoff KM1004-0001 minimizes field wiring volume while maintaining clean cabinet organization.

Key Features

  • High-Density Discrete Sensing: Houses 32 digital inputs structured across four 8-channel groupings.
  • 1-Wire Pluggable Design: Bundled with a 1-wire tension clamp connector block for fast installation and field-level toolless maintenance.
  • Integrated Signal Filtering: Employs a standard 3.0 ms hardware input filter to prevent relay contact bounce and electromagnetic interference.
  • Complete Electrical Isolation: Rated for up to 500 V isolation between the internal K-bus and the external field potential.
  • Modular Scalability: Fully integrates into standard Beckhoff K-bus networks alongside traditional 12 mm Bus Terminals.

Applications

  • Concentrated sensor integration in food processing and packaging machinery.
  • I/O expansion for material handling, conveyor systems, and sorting lines.
  • High-density control cabinet assemblies with limited physical mounting depth.

Product Suffix Variants

Order Code Connection Method LED Status Indicators
KM1004-0000 Pluggable connection (shipped without connector headers) No
KM1004-0001 1-wire pluggable connector (included) No
KM1004-0002 1-wire pluggable connector (included) Yes
KM1004-0004 3-wire pluggable connector (included) Yes

Technical Specifications

Manufacturer Beckhoff
Part Number / SKU KM1004-0001
Number of Inputs 32 (4 x 8 channels)
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 V to +5 V
"1" Signal Voltage 15 V to 30 V
Input Filter Time typ. 3.0 ms
Input Current typ. 5 mA
Current Consumption K-Bus typ. 3 mA
Current Consumption Power Contacts None (no power contacts implemented)
Electrical Isolation 500 V (K-bus / field potential)
Process Image Bit Width 32 inputs
Connection Cross-Section 0.08 to 1.5 mm2 (solid or stranded)
Stripping Length 8 mm
Dimensions (W x H x D) 75 mm x 100 mm x 55 mm
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95% non-condensing
Protection Class IP20
Standard Compliance EN 61131-2 Type 1, EN 60068-2-6, EN 60068-2-27
Shipping Weight (Calculated) 0.20 kg (including plug-in assembly block)

Empirical Engineering Insights

Alternative Models & Compatibility

The KM1004-0001 is functionally identical to the KM1004-0000, except it is bundled from the factory with the compatible 1-wire ZS2001-0001 female header plugs. For configurations requiring visible diagnostics directly on the terminal face, the KM1004-0002 serves as the direct physical alternative, offering built-in state-tracking LEDs. The modular connector plates can be hot-swapped onto the same base unit without altering the system’s physical footprint.

Application Pitfalls & Engineering Notes

Be advised that the KM1004-0001 has no integrated power contacts. Field-side sensors cannot draw positive potential or ground loops directly from internal terminal pass-throughs. If utilizing multi-wire field sensors, external potential distributors (such as KL9100) must be positioned adjacent to the module to supply the reference potential. Additionally, always ensure that K-bus power consumption margins are budgeted in the system coupler configuration to prevent voltage drops.

Commissioning & Wiring Tips

When assembling the ZS2001-0001 header block, maintain an exact 8 mm stripping length. Stranded wires without ferrules should be installed with precision to avoid stray strands bridging neighboring terminal pins inside the high-density header. To avoid capacitive cross-talk within high-channel installations, keep the 24 V DC digital signal wires logically separate from 230/400 V AC power runs.

Installation Guidelines

CRITICAL WARNING:

Isolate all 24 V DC field power and K-bus primary power circuits before mounting, dismounting, or wiring this terminal module. Working with active electrical systems can trigger high-frequency noise spikes, damage solid-state K-bus interfaces, or lead to unintentional machine movement.

1
Position the KM1004-0001 module onto the 35 mm DIN rail (EN 60715) and push down firmly until the integrated locking hook securely snaps onto the rail profile.
2
Slide the female connector header (ZS2001-0001) into the housing guide channels until it locks flush with the terminal front face.
3
Terminate the 24 V DC field inputs utilizing standard tension-clamp tools, using stripped 0.08 to 1.5 mm2 solid or stranded conductors.
4
Power up the K-bus rail system and map the 32 input bits inside TwinCAT or other compatible PLC configuration platforms to verify full I/O mapping logic.
Loading product navigation…

What is the key difference between the KM1004-0001 and the KM1004-0000?

The KM1004-0001 includes the physical 1-wire ZS2001-0001 plug-in female terminal headers in the package, whereas the KM1004-0000 is supplied as the bare housing module without terminal blocks.

Does this module support feed-through electrical power contacts?

No. The KM1004-0001 has no integrated power contacts. Sensor supply voltage and grounds must be connected using external potential terminal distribution blocks.

What size wire can be used with the included plug-in connectors?

The terminal block accommodates both solid and stranded electrical conductors ranging from 0.08 to 1.5 mm2 (28 to 16 AWG).

Does this digital input module require hardware configuration settings?

No configuration or manual address settings are required. The module is automatically detected on the K-bus and maps 32 bits straight into the PLC controller process image.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...