1 из 3

Bently Nevada 136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations

Bently Nevada 136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations

Остался только 6 товар(ы) на складе
  • Производитель: Bently Nevada

  • Номер продукта: 136711-02

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: RTD/TC I/O Module

  • Штрихкод: 8537101190

  • Оплата: Банковский перевод (T/T), Western Union

  • Вес: 460г

  • Размеры: 24.4 mm x 241.3 mm x 163.1 mm (W x H x D)

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

The Bently Nevada 136711-02 is a non-isolated RTD/TC I/O module with internal barriers and internal terminations designed for processing temperature transducer inputs within the 3500 Machinery Protection System. Installed in a full-height rear slot directly behind the 3500/61 Temperature Monitor main module, it accepts input signals from up to six Resistance Temperature Detector (RTD) or Thermocouple (TC) transducers. The 136711-02 channels conditioned signals and +4 to +20 mA proportional recorder outputs through integrated internal barriers to support intrinsically safe machinery monitoring applications in industrial environments.

Features

  • Provides internal zener barriers and internal termination wiring connectors for six input channels
  • Interface options configurable for 3-wire RTD, 4-wire RTD, and Thermocouple transducers
  • Integrates directly behind the 3500/61 Temperature Monitor via the 3500 system backplane
  • Routes +4 to +20 mA proportional recorder outputs for each individual channel

Applications

  • Bearing temperature monitoring in rotating machinery such as turbines, compressors, and pumps
  • Process temperature measurement using RTD and TC transducers in hazardous location areas
  • Machinery protection and condition monitoring within the 3500 system architecture

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Part Number 136711-02
Compatible Main Module 3500/61 Temperature Monitor
Module Type RTD/TC Non-Isolated I/O Module with Internal Barriers and Internal Terminations
Number of Channels Accepts 1 to 6 RTD or TC transducer signals
Input Impedance Greater than 10 Mohm for each lead input
Thermocouple Types Type E (-100 degC to +1000 degC), Type J (0 degC to +760 degC), Type K (0 degC to +1370 degC), Type T (-160 degC to +400 degC)
RTD Types 100 ohm 3-wire & 4-wire platinum (alpha = 0.00385 or 0.00392), 120 ohm 3-wire & 4-wire nickel, 10 ohm 3-wire & 4-wire copper
RTD Current Source Value 925 +-15 uA at 25 degC per transducer
Recorder Outputs +4 to +20 mA proportional to monitor full-scale (individual per channel)
Voltage Compliance (Current Output) 0 to +12 Vdc range across load (0 to 600 ohm load resistance)
Recorder Output Resolution 0.3662 uA per bit +-0.15% error at room temperature (+-0.4% error over temperature range)
Operating Temperature 0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier I/O Modules
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Rack Space Requirement 1 full-height rear slot
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)
Weight 0.46 kg (1.01 lbs)

Installation Guidelines

  • Install the I/O module in a single full-height rear slot positioned directly behind the corresponding 3500/61 Temperature Monitor module.
  • Secure wiring connections to the green and blue internal termination connector headers according to transducer type wiring configurations.
  • Ensure operating ambient temperatures remain within the designated limit of 0 degC to +65 degC when internal barriers are active.

Compliance and Certifications

Certification / Standard Standard / Details
EMC Directive 2004/108/EC (EN 61000-6-2, EN 55011/CISPR 11, EN 61000-6-4)
Low Voltage Directive 2006/95/EC (EN 61010-1)
North American Hazardous Area Approval Ex nC [ia] IIC: Class I, Div 1; AEx nC [ia] IIC: Class 1, Zone 2/0 Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC
ATEX Approval II 3/(1) G, Ex nC[ia Ga] IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC
Brazil Approval (3500/61 only) BR-Ex nC[nL] IIC T4, T4 @ Ta = -20 degC to +65 degC
South Africa Approval Ex nCAL [ia] IIC T4, Ex nCAL [L] IIC T4, T4 @ Ta = -20 degC to +65 degC
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations

Which slot position does the module occupy in the chassis?

The module installs in a full-height rear slot directly behind the 3500/61 Temperature Monitor main card.

What transducer inputs can be connected to the terminals?

The module accepts up to six RTD or Thermocouple inputs, including Type E, J, K, and T thermocouples or platinum, nickel, and copper RTDs.

What temperature range is permitted for module operation?

The operating temperature range is 0 degC to +65 degC when deployed with internal barrier I/O configurations.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, оформленных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Color pattern
Серовато-белый
Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Модернизация человеко-машинных интерфейсов Bailey INFI 90 Symphony под управлением OpenVMS Alpha

Практическое руководство по замене устаревающих операторских станций Bailey Symphony на базе OpenVMS Alpha. В нём сравниваются эмуляция Alpha, миграция на OpenVMS x86, перенос на платформу OPC и...

Почему данные о техническом обслуживании необходимы для обеспечения надёжности промышленного оборудования

Данные о техническом обслуживании объединяют рабочие заказы, сигналы датчиков, историю активов, затраты и знания технических специалистов. При правильном использовании они улучшают планирование,...

Электрические приводы, разработанные для замены гидравлических и пневматических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator компании SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для приложений промышленной автоматизации

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, вычисление остатка от деления и возведение в степень, в...