Providing dedicated, continuous machine-level machinery protection, the Bently Nevada 1900/65A-00-00-03-00-00 functions as a rugged, standalone four-channel monitor configured for critical machinery parameters such as vibration, temperature, position, and speed. The 1900/65A series architecture integrates transducer conditioning, alarm detection, and output relays into a single, compact system. This specific variation operates on 18 to 36 Vdc power, features no local display for streamlined remote control configurations, and is safely housed inside a weatherproof Fiberglass NEMA 4X/IP66 enclosure with a clear viewing window. By combining dynamic dynamic-channel processing with static temperature inputs, it reliably monitors cooling towers, small pumps, and industrial fans without requiring a larger rack-based DCS framework.

Features

  • Four dynamic input channels compatible with acceleration, velocity, or proximity sensors.
  • Two dedicated temperature channels accepting 3-wire RTD or Type E, J, K, and T thermocouples.
  • Six configurable relay outputs (four SPDT alarm relays and two system-status relays) for direct equipment trip control.
  • Four 4-20 mA analog outputs providing continuous telemetry data to external PLCs or SCADA platforms.
  • NEMA 4X/IP66-rated fiberglass housing with a transparent door window for field monitoring in harsh environments.
  • No display configuration reduces auxiliary power requirements and prevents unauthorized field tampering.

Applications

  • Cooling tower fan gearboxes and structural vibration monitoring.
  • Industrial air compressors and processing blowers.
  • Electric motors, centrifugal pumps, and secondary water circulation loops.
  • Small-scale steam and gas turbines in cogeneration plants.

Ordering Information

Option Code Option Type Configuration Detail
1900/65A Base Model General Purpose Equipment Monitor
00 Power Option 18 to 36 Vdc
00 Display Option No local display unit
03 Mounting Option Fiberglass NEMA 4X/IP66 WP housing with window in door
00 Approvals Option No hazardous area approvals
00 Communications None (Standard Analog/Relay Interface Only)

Technical Specifications

Parameter Specification value
Supply Voltage Range 18 to 36 Vdc (24 Vdc nominal)
Power Consumption 3.0 Watts typical, 8.0 Watts maximum
Dynamic Signal Inputs 4 channels, supports Proximitor, Accelerometers, and Velomitors
Temperature Inputs 2 channels, RTD (3-wire 100 ohm Platinum) or Thermocouples (E, J, K, T)
Relay Outputs 4 programmable alarm relays, 2 system status relays (SPDT, 5 A at 250 Vac)
Analog Recorder Outputs Four 4 to 20 mA outputs (internally powered, max loop resistance 600 ohms)
Frequency Response 0.2 Hz to 20,000 Hz (sensor dependent)
Enclosure Classification NEMA 4X / IP66 Weatherproof
Operating Temperature -20 to +70 degC (-4 to +158 degF)
Net Weight 0.77 kg (1.7 lbs) (excluding enclosure)
Shipping Weight (Calculated) 2.00 kg (4.4 lbs)
Package Dimensions (Calculated) 320 mm x 240 mm x 180 mm
Manufacturer Bently Nevada (Baker Hughes)
Country of Origin United States

Connections and Interfaces

Terminal Block Pin / Designation Function / Circuit Assignment
TB1 Power (+), Power (-), GND 18-36 Vdc Power Connection & Chassis Ground
TB2 Ch 1 & Ch 2 (+ / - / S) Dynamic Transducer Inputs (Proximity / Accelerometers)
TB3 Ch 3 & Ch 4 (+ / - / S) Dynamic Transducer Inputs (Proximity / Accelerometers)
TB4 A, B, C (Ch 5 & Ch 6) RTD Leads or Thermocouple Cold Junction Inputs
TB5 Relay 1 to Relay 4 SPDT Dry Contact Alarm Interlocks

Empirical Engineering Insights

Alternative Models & Compatibility

The 1900/65A series directly replaces the older legacy 1900/65 platforms. However, configuration files created under the non-A version cannot always be uploaded directly without validation. Ensure you run Bently Nevada Configuration Software Version 1.4 or higher to translate older configuration profiles into the 1900/65A firmware structure.

Application Pitfalls & Engineering Notes

Because this model features the 00 (No Display) option, local physical troubleshooting is restricted to internal LED status indicators. For remote locations, configure the four 4-20 mA outputs to stream directly to a control room DCS to track individual sensor health and prevent blind operation. Additionally, ensure the internal NEMA 4X housing temperature does not consistently exceed 70 degC when switching inductive relay loads at maximum current limits.

Commissioning & Wiring Tips

Always isolate dynamic signal shields from structural earth at the machine end. Sensor shields must terminate strictly at the monitor's TB2 and TB3 shield contacts. Running a single-point ground layout back to the central DC common minimizes high-frequency electromagnetic noise from variable-frequency drives (VFDs) that could otherwise trigger false dynamic alerts.

Installation Guidelines

CRITICAL WARNING: Ensure all primary and auxiliary DC power sources are completely de-energized and locked out before removing the fiberglass cover or inserting wire connections. Verify that any high-voltage relay loads are fully isolated to prevent high-voltage arcing across adjacent terminals.
1

Mount the NEMA 4X fiberglass enclosure securely to a rigid, vibration-free surface using standard mounting hardware to prevent auxiliary structural vibration from corrupting dynamic channel signals.

2

Route dynamic sensor cables and power cables through separate conduit entries to avoid cross-coupling noise on sensitive transducer circuits.

3

Terminate the 18 to 36 Vdc power feeds on terminal block TB1, observing correct polarity to prevent trigger startup failure or protection loop faults.

4

Connect your configuration computer to the internal serial port using the dedicated Bently Nevada programming interface to program sensor scales, trip limits, and dynamic filtering configurations.

Loading product navigation…

Does this monitor support external Modbus communications?

No. The 1900/65A-00-00-03-00-00 has option code 00 for communications, meaning it does not contain Modbus or industrial Ethernet capabilities. It relies entirely on physical relays and four 4-20 mA analog outputs for interfacing with external control devices.

Can I run dynamic vibration sensors and temperature probes simultaneously?

Yes. It supports four dynamic channels (e.g., accelerometers, proximity probes) and two static channels (e.g., RTDs, thermocouples) concurrently, acting as an all-in-one regional machinery monitor.

What software is required to configure the 1900/65A without a display?

Configuration requires the Bently Nevada 1900 Configuration Software utility. It connects directly via a dedicated programming interface located inside the fiberglass enclosure.

Is the enclosure suitable for outdoor installations?

Yes. The fiberglass enclosure is rated NEMA 4X and IP66, which guarantees protection against rain, sleet, external ice formation, and direct water spray.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...