1 из 1

Mitsubishi Electric FR-A840-00250-2-60 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-00250-2-60 FR-A800 Series Variable Frequency Drive

Остался только 10 товар(ы) на складе
  • Производитель: Mitsubishi Electric

  • Номер продукта: FR-A840-00250-2-60

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: Variable Frequency Drives

  • Оплата: Т/Т, Western Union

  • Вес: 9000г

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Engineered for high-demand industrial speed and torque applications, the Mitsubishi Electric FR-A840-00250-2-60 is a premium FR-A800 Series variable frequency drive operating in the 400V voltage class. This standard-model inverter features specialized circuit board protective coating compliant with 3C2 specifications (without plated conductors) to ensure long-term reliability in corrosive, humid, or dusty environments. It supports advanced vector control methods to deliver precise motor dynamics for heavy-duty applications like cranes, extruders, and ventilation systems.

Key Features

  • Conformal PCB Coating: Engineered with standard 3C2-rated circuit board coating to withstand high moisture, chemical exposure, and particulate accumulation.
  • Advanced Vector Control: Supports real sensorless vector control and closed-loop vector control for absolute torque precision down to zero speed.
  • Dual Rating Capability: Optimizes sizing by allowing selection between Super Light Duty (SLD), Light Duty (LD), Normal Duty (ND), and Heavy Duty (HD) profiles.
  • Built-in PLC Functionality: Program internal logic using Mitsubishi Electric developer software to manage local I/O without an external controller.
  • Comprehensive Safety: Integrated safe torque off (STO) safety terminals comply with SIL 2 / PL d standards.

Applications

  • Material Handling: Dynamic hoist control, crane gantry synchronization, and heavy-duty conveyor systems requiring high starting torque.
  • Process Pumps & Compressors: Variable flow management under fluctuating load profiles in chemical processing and water treatment facilities.
  • Extruders and Mixers: High-inertia load management with precise speed holding under varying material viscosity.
  • Metalworking and Tensioning: Precise torque limitation and winding/unwinding control loops.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Code FR-A840-00250-2-60
Series FR-A800
Voltage Class 400 V Class (3-phase 380 to 500 V AC, 50Hz/60Hz)
SLD Rated Current 25.0 A
Control Method V/F Control, Advanced Magnetic Flux Vector, Real Sensorless Vector
PCB Coating Type Conformally Coated (Class 3C2), without plated conductor (-60)
Enclosure Rating IP20 (Open Type)
Operating Temperature -10 degC to 50 degC (non-freezing)
Device Net Weight 6.7 kg
Shipping Weight (Calculated) 9.0 kg

Control Terminals & Wiring Assignments

Terminal Symbol Terminal Name Functional Description
STF Forward Rotation Start Turn ON STF to start forward rotation; turn OFF to decelerate and stop.
STR Reverse Rotation Start Turn ON STR to start reverse rotation; turn OFF to decelerate and stop.
SD Contact Input Common Common terminal for contact input signals (sink logic standard).
10 Frequency Setting Power Supply DC 10V output for analog speed reference potentiometers.
2 Frequency Setting (Voltage) DC 0 to 5V or 0 to 10V analog speed command input.
4 Frequency Setting (Current) 4 to 20 mA DC analog speed command input.

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A840-00250-2-60 is directly backward compatible with older FR-A740-00250-EC installations. Users migrating to the FR-A800 series must utilize FR Configurator2 to convert parameter settings, ensuring torque boost and motor tuning values map correctly to the updated algorithm structure.

Application Pitfalls & Engineering Notes

When utilizing this inverter in closed cabinets, account for the 6.7 kg thermal footprint. Adequate airflow clearance must be maintained: 5 cm on both sides and 10 cm above/below the unit. Operating in temperatures exceeding 40 degC requires carrier frequency derating via Parameter 72 to prevent overtemperature tripping (E.THT or E.FIN).

Commissioning & Wiring Tips

Ensure that all analog control signals (terminals 2, 4, and 10) are wired with shielded, twisted-pair cables. Ground the shield exclusively at the drive-end SD terminal to prevent ground loops. Never route motor output leads (U, V, W) in the same conduit as control or communications cables.

Installation Guidelines

CRITICAL WARNING: Ensure main input line power (R/L1, S/L2, T/L3) is completely de-energized and locked out before attempting installation or maintenance. Wait a minimum of 10 minutes post-power-down for the DC bus capacitors to discharge. Verify the DC voltage across terminals P/+ and N/- is below 30V using a calibrated digital multimeter before handling terminals.
1

Mount the inverter vertically to a flat, rigid metal backplate to ensure optimal heat dissipation and grounding path efficiency.

2

Connect the protective earth (PE) terminal to the system ground busbar using low-impedance braided strap or green-and-yellow grounding conductor.

3

Wire the three-phase AC input to R/L1, S/L2, T/L3, and connect the motor leads to U, V, and W. Do not install a power factor correction capacitor on the output side.

4

Establish control wiring loop via standard sink logic or switch to source logic configuration utilizing the internal jumper block as specified by system drawings.

Loading product navigation…

What is the meaning of the -60 suffix on this inverter?

The -60 suffix denotes a standard model built with conformal circuit board coating compliant with IEC 60721-3-3 Class 3C2 for chemical/corrosive resistance, but without plated conductors.

Can I use the FR-A840-00250-2-60 with a single-phase supply?

No. This 400V class model is designed strictly for a balanced 3-phase AC input (380 to 500V, 50Hz or 60Hz).

How long must I wait to service the drive after disconnecting power?

You must wait at least 10 minutes to allow the DC bus capacitors to fully discharge. Always measure the DC voltage across terminals P/+ and N/- to confirm it is below 30V before handling.

Does this model support Modbus RTU communications out of the box?

Yes. This drive features built-in RS-485 communication ports on the control terminal block supporting Modbus RTU protocol as standard.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...