Engineered to optimize centrifugal pump and fan efficiency across demanding industrial networks, the Mitsubishi Electric FR-F840-01160-2-60 Variable Frequency Drive delivers precision speed control within the high-performance FR-F800 Series. This unit features advanced energy-saving algorithms and robust hardware tailored for hostile atmospheres. The FR-F840-01160-2-60 carries a heavy-duty design rating of 55 kW, utilizing specialized protective circuit board coatings to extend its operational lifespan in corrosive or humid environments.

Key Technical Features

  • Coated Circuit Boards: Enhanced protection class featuring specialized PCB varnish conformal coating (indicated by the "-60" designation) and non-plated conductors to resist moisture and airborne contaminants.
  • Advanced Energy Saving: Built-in optimum excitation control algorithms continuously optimize motor flux, reducing energy consumption under variable torque loads.
  • Intelligent Load Diagnostics: Detects mechanical blockages, dry run states, or belt breakage by comparing operating torque signatures against pre-configured limit curves.
  • Dual-Channel Safety STO: Integrated Safe Torque Off (STO) inputs for compliant emergency stop performance without redundant external contactors.

Industrial Applications

  • Municipal Water Treatment: Precision pressure regulation for booster pumps, sewage aerators, and chemical dosing systems.
  • HVAC & Building Automation: Large-scale industrial chillers, cooling towers, and air handling units (AHUs).
  • Material Processing: Exhaust fans, ventilation blowers, and secondary pump loops in metallurgy and chemical manufacturing plants.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Code FR-F840-01160-2-60
Series Name FR-F800
Applicable Motor Capacity 55 kW
Rated Output Current 116 A
Output Rated Capacity 88 kVA
Input Voltage Phase / Freq Three-phase 380 to 500 V AC, 50 Hz / 60 Hz
Voltage Fluctuation Range 323 to 550 V AC, 50 Hz / 60 Hz
Frequency Fluctuation Range +/- 5 percent
Power Supply Capacity 107 kVA
IP Rating / Enclosure IP00 (Open Type, JEM1030)
Cooling System Forced Air Cooling
Country of Origin Japan
Unit Net Weight 41.0 kg
Shipping Weight (Calculated) 47.0 kg

Power Terminal Configurations

Terminal Designation Functional Assignment / Circuit Role
R/L1, S/L2, T/L3 Three-phase AC power input connections
U, V, W Three-phase variable frequency output to AC induction motor
P/+, PR DC Bus positive / connection to dynamic braking resistor
P/+, N/- DC Bus common link connection for regenerative converter configurations
Earth / Ground (PE) Chassis grounding terminal for electrical noise safety compliance

Alternative Models & Compatibility

Standard units in this catalog range carry a "-1" suffix for baseline industrial environments. The FR-F840-01160-2-60 features a "-2" region designator (equivalent to standard CA functional specification with embedded European/Chinese EMC filter standards) combined with the protective "-60" suffix. It is directly backwards-compatible in mechanical sizing with standard FR-F740 models of equivalent physical footprint, though parameters must be translated via FR Configurator2 software prior to operational start.

Application Pitfalls & Engineering Notes

Because this unit is an IP00 open-type chassis, it is susceptible to direct environmental ingress if left unhoused. Mounting inside an IP54 or higher rated MCC panel is required. The drive dissipates approximately 1.5 kW of heat under full-load operation. Ensure your panel's thermal engineering supports forced ventilation calculation rates of at least 250 cubic meters per hour to avoid over-temperature trips.

Commissioning & Wiring Tips

Keep analog control lines completely separated from high-energy output cables. Ground shielding for terminal connections must terminate at the grounding plate immediately adjacent to the VFD chassis. Do not short the SD terminal (control common) to the safety earth (PE) ground, as this initiates ground loops that cause noise-induced controller resetting.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE HAZARD

De-energize all primary supply lines before removing the terminal block covers. Allow a minimum of 10 minutes for internal DC bus capacitors to fully discharge. Always verify that voltage between terminals P/+ and N/- is below 50 V DC with a calibrated voltmeter before executing any physical wiring or maintenance steps.

1
Mounting Alignment

Mount the chassis vertically on an unpainted, flat metal backplate to ensure continuous electrical ground continuity. Maintain 100 mm clearances above and below the cooling vents.

2
High-Power Conduit Separation

Route AC input (R/L1, S/L2, T/L3) and output motor connections (U, V, W) through separate metallic conduits to prevent cross-talk and high-frequency interference.

3
Control Cable Shield Grounding

Ground all control shields directly at the cable clamp. Terminate control signals on separate paths from power wiring. Avoid connecting terminal SD to structural PE ground.

Loading product navigation…

What does the -60 suffix signify on this specific drive?

The -60 suffix denotes that the printed circuit boards have specialized conformal coatings and use non-plated conductors, protecting the sensitive interior circuitry from moisture, corrosive gases, and harsh environments.

What is the physical protective rating of this drive housing?

This drive is an open-type chassis rated at IP00. It must be installed inside a secondary protective enclosure, such as an IP54-rated control cabinet, to defend against dust and water ingress.

Does this model include a built-in EMC filter?

Yes, the regional symbol '2' represents the CA specification model, which comes with an integrated European and Chinese standard EMC filter to minimize electromagnetic feedback into your main power lines.

What size motor is compatible with this frequency inverter?

This drive is designed to control three-phase AC induction motors with a power rating of up to 55 kW and a continuous output rating of 116 A.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...