Description

Integrating serial Modbus connectivity directly into Allen-Bradley 1794 FLEX I/O systems is efficiently achieved using the MVI94-MCM communication module. Designed to function as a bridge between the Modbus protocol and the Rockwell Automation backplane, this module enables a host processor to interface seamlessly with field telemetry devices, SCADA systems, instruments, and PLC-based networks. The MVI94-MCM operates as either a Modbus Master or a Modbus Slave, offering versatile network configuration options for complex industrial systems.

The module occupies a single slot in the 1794 backplane and provides a reliable communication link using serial communication. It features optical isolation to protect sensitive control equipment from electrical noise and ground loop hazards. System configuration and maintenance are simplified through a dedicated, hardware-handshaking serial port, while application communications are handled via a jumper-selectable secondary port.

Features

  • FLEX I/O Compatibility: Installs directly into any standard Allen-Bradley 1794 backplane slot.
  • Dual-Port Architecture: Provides a dedicated serial configuration port (PRT1) and a multi-protocol serial application port (PRT2).
  • Protocol Versatility: Configurable as a Modbus Master or Modbus Slave device.
  • Robust Isolation: Application serial port includes 500V optical isolation from the backplane to prevent electrical noise propagation.
  • Physical Interface Selectivity: Jumper-selectable configurations on the application port support RS-232, RS-422, and RS-485 communication standards.
  • Diagnostic Diagnostics: LEDs display module status, backplane transfer, application status, and active serial port communication activity.

Applications

  • SCADA and telemetry interface integration in oil and gas pipelines.
  • Power distribution monitoring and electrical substation automation.
  • Water and wastewater remote terminal unit (RTU) coordination.
  • Inter-system PLC and DCS networking in chemical processing facilities.

Technical Specifications

Manufacturer ProSoft Technology
Part Number / Model MVI94-MCM
Series MVI94
Product Type Modbus Master/Slave Communication Module
Form Factor Single Slot 1794 Backplane compatible (any slot)
Backplane Current Load 20 mA @ 5 VDC
External Power Supply 12 to 24 VDC (340 to 170 mA)
Operating Temperature 0 to 55 degC (32 to 131 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% (without condensation)
Module Dimensions (H x W x D) 9.4 cm x 9.4 cm x 6.9 cm
Shipping Weight 2.0 kg

Connections and Interfaces

Port Designation Physical Connector Type Supported Protocols / Hardware Standards Isolation
PRT1 (Configuration Port) Mini-DIN RS-232 with Hardware Handshaking None
PRT2 (Application Port) Mini-DIN RS-232, RS-422, or RS-485 (Jumper Selectable) 500V optical isolation from backplane

Installation Guidelines

  • Terminal Base Mounting: Mount the module securely onto a compatible 1794 terminal base unit before applying power to the backplane.
  • Jumper Settings: Ensure the hardware jumper settings on the module side panel are configured correctly for the desired physical interface (RS-232, RS-422, or RS-485) prior to mounting and commissioning.
  • External Power Supply Wiring: Connect a clean 12 to 24 VDC external power source to the designated terminal base connections to power the transceiver circuits.
  • Grounding: For optimal optical isolation performance and noise reduction, ensure the terminal base and cabinet housing are properly connected to a low-impedance earth ground.
Loading product navigation…

What control platform is the ProSoft MVI94-MCM designed for?

The ProSoft MVI94-MCM is designed specifically for the Rockwell Automation 1794 FLEX I/O platform, mounting into a single backplane slot.

What are the power requirements for the MVI94-MCM module?

The module requires a 20 mA backplane current at 5 VDC, in addition to an external 12 to 24 VDC power supply drawing between 340 mA and 170 mA.

Does the application port on the module support RS-485?

Yes, the application port (PRT2) supports RS-232, RS-422, and RS-485 physical communication interfaces via jumper selection.

What is the level of isolation provided on the application port?

The application serial port (PRT2) features 500V optical isolation from the backplane to prevent noise and ground loops.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...