1 из 1

Weidmuller 1504470000 IE-GWT-MB-2TX-1RS232/485 Modbus TCP/RTU Gateway

Weidmuller 1504470000 IE-GWT-MB-2TX-1RS232/485 Modbus TCP/RTU Gateway

Остался только 10 товар(ы) на складе
  • Производитель: Weidmuller

  • Номер продукта: IE-GWT-MB-2TX-1RS232/485

  • Страна происхождения:Германия

  • Тип продукта: Modbus Gateways

  • Оплата: Т/Т, Western Union

  • Вес: 1000г

  • Размеры: 29 mm x 124.5 mm x 89.2 mm

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Facilitating seamless protocol translation between serial Modbus RTU/ASCII and Ethernet-based Modbus TCP networks, the Weidmuller 1504470000 (model IE-GWT-MB-2TX-1RS232/485) serves as an industrial-grade communication gateway designed for high-reliability automation environments. This device bridges legacy serial field devices with modern Ethernet control architectures, ensuring low-latency data transmission and robust network integration.

Key Features

  • Dual Ethernet ports (2TX) allowing for daisy-chain network topologies and simplified cabling.
  • Software-selectable serial interface supporting RS-232, RS-422, and RS-485 configurations.
  • Redundant 24 V DC power inputs to maximize system uptime and operational resilience.
  • Integrated Serial Redirection and Priority Control for optimized traffic management.
  • Compact, space-saving IP30 plastic housing designed for standard DIN rail mounting.

Applications

  • Substation automation and power monitoring network integration.
  • Connecting legacy serial PLCs and RTUs to modern SCADA host systems.
  • Water and wastewater treatment facility remote telemetry.
  • Factory automation and machine-to-machine (M2M) communication bridging.

Technical Specifications

Parameter Value
Manufacturer Weidmuller
Article Number (SKU) 1504470000
Model Designation IE-GWT-MB-2TX-1RS232/485
Ethernet Ports 2x RJ45 (10/100BaseT(X))
Serial Ports 1x RS-232/425/485 (DB9 male or terminal block options)
Supply Voltage 24 V DC (Redundant inputs)
Connector Type 1 removable 7-pole terminal block
Operating Temperature -40 to 75 degC
Storage Temperature -40 to 85 degC
Ambient Relative Humidity 5% to 95% (non-condensing)
Protection Class IP30
Housing Material Plastic
Mounting Type DIN rail
Dimensions (W x H x D) 29 mm x 124.5 mm x 89.2 mm
Net Weight 190 g
Shipping Weight (Calculated) 1.0 kg

Connections and Interfaces

Interface / Terminal Functional Assignment
7-Pole Terminal Block Redundant Power Input 1 (V1+, V1-), Redundant Power Input 2 (V2+, V2-), Functional Earth (FE)
RJ45 Ports (1 & 2) 10/100BaseT(X) Ethernet interfaces with auto MDI/MDI-X crossover detection
Serial Port RS-232 (TxD, RxD, GND) / RS-485 (Data+, Data-, GND) software-configurable pins

Empirical Engineering Insights

Alternative Models & Compatibility

The IE-GWT-MB-2TX-1RS232/485 is backward compatible with standard Modbus RTU devices operating over RS-485 2-wire networks. When replacing older single-port serial servers, the dual Ethernet ports on this model eliminate the need for an external switch in simple line topologies, reducing overall panel hardware costs.

Application Pitfalls & Engineering Notes

In high-density electrical cabinets, ensure adequate clearance around the IP30 plastic housing to maintain natural convection cooling. While rated up to 75 degC, operating continuously at extreme temperatures without proper ventilation can accelerate component aging. Always verify that the Modbus TCP client timeout settings are configured to accommodate the serial bus latency, especially when polling multiple daisy-chained RTU slaves.

Commissioning & Wiring Tips

When wiring the RS-485 network, always install a 120-ohm termination resistor at both physical ends of the communication line to prevent signal reflections. Ensure the Functional Earth (FE) terminal on the 7-pole block is connected directly to a low-impedance ground plane to safeguard the internal transceiver circuits from transient voltage spikes and electromagnetic interference.

Installation Guidelines

CRITICAL WARNING

Disconnect all power sources before attempting installation, wiring, or removal of the gateway. Failure to de-energize the system can result in electrical shock, equipment damage, or unexpected control system behavior.

1

Mount the gateway onto a standard TS 35 DIN rail, ensuring the locking mechanism snaps firmly into place.

2

Connect the Functional Earth (FE) terminal to the local ground system to ensure proper noise immunity.

3

Wire the redundant 24 V DC power supplies to the removable 7-pole terminal block, verifying correct polarity before energizing.

4

Connect the RJ45 Ethernet cables and the serial interface lines, securing all physical connections.

Loading product navigation…

What is the purpose of the dual Ethernet ports on the Weidmuller 1504470000?

The dual RJ45 ports (2TX) allow for daisy-chaining multiple Ethernet devices in a line topology, reducing the need for external network switches and simplifying field wiring.

Does this gateway support redundant power inputs?

Yes, the device features redundant 24 V DC power inputs via a removable 7-pole terminal block to ensure continuous operation if one power source fails.

How do I configure the serial port for RS-485 or RS-232?

The serial interface configuration (RS-232, RS-422, or RS-485) is software-selectable through the gateway's web-based management utility or configuration software.

What is the operating temperature range of the IE-GWT-MB-2TX-1RS232/485?

The gateway is designed for harsh environments, supporting an operating temperature range of -40 to 75 degC.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...

Программирование циклов одноосевого движения на сервоприводе CMZ

В этом руководстве рассматривается, как встроенный ПЛК внутри серводрайвера CMZ SBD может выполнять автономные программы движения, включая логику поиска нуля, позиционное управление и циклическое...