Weidmuller 8965420000 ACT20X-2SDI-2HDO-S Valve Control Module

Weidmuller 8965420000 ACT20X-2SDI-2HDO-S Valve Control Module

Остался только 10 товар(ы) на складе
  • Производитель: Weidmuller

  • Номер продукта: 8965420000

  • Страна происхождения:Германия

  • Тип продукта: Intrinsically Safe Valve Drivers

  • Оплата: Т/Т, Western Union

  • Вес: 1200г

  • Размеры: 117.2 mm x 22.5 mm x 113.6 mm

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Facilitating the safe control of intrinsically safe valves in hazardous environments, the Weidmuller 8965420000 (ACT20X-2SDI-2HDO-S) provides reliable signal isolation and switching. This dual-channel valve control module acts as an isolated barrier, translating control signals from the safe area into intrinsically safe outputs to drive solenoids, valves, and acoustic alarms located in Ex zones.

Key Features

  • Dual-Channel Isolation: Supports two independent channels for space-saving, high-density cabinet layouts.
  • Integrated Diagnostics: Built-in alarm function detects and reports supply voltage loss and internal device errors.
  • Software Configurable: Fully compatible with FDT/DTM software for precise parameter adjustment and monitoring.
  • Secure Connections: Equipped with robust screw terminals to ensure vibration-resistant field wiring.
  • Compact Profile: 22.5 mm housing width optimizes DIN-rail space in control enclosures.

Industrial Applications

  • Oil & Gas Refineries: Actuation of intrinsically safe solenoid valves in hazardous processing zones.
  • Chemical Processing: Safe signal transmission and isolation for chemical dosing and distribution systems.
  • Pharmaceutical Manufacturing: Control of pneumatic and hydraulic valves in explosive dust or gas atmospheres.
  • Water & Wastewater Treatment: Isolated valve control in wet wells and chemical treatment areas.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Weidmuller
Article Number (SKU) 8965420000
Model Designation ACT20X-2SDI-2HDO-S
Product Type Intrinsically Safe Valve Control / Solenoid Driver
Number of Channels 2
Supply Voltage Range 19.2 to 31.2 V DC
Power Consumption <= 3.1 W
Nominal Switching Voltage <= 125 V AC / 110 V DC
Continuous Current <= 0.5 A AC / 0.3 A DC
Step Response Time 10 ms
Configuration Method FDT/DTM software
Connection Type Screw connection
Operating Humidity 0 to 95% (non-condensing)
Protection Degree IP20
Net Weight 0.180 kg
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Shipping Weight (Calculated) 1.2 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The ACT20X-2SDI-2HDO-S is highly compatible with standard DCS and PLC digital output cards. When integrating this module into existing systems configured with older ACT20 series units, ensure that the FDT/DTM frame application is updated to the latest device description files to prevent communication errors during setup.

Application Pitfalls & Engineering Notes

When mounting multiple units side-by-side on a DIN rail, ensure the cabinet's thermal management system is active. Under maximum continuous current loads (0.5 A AC / 0.3 A DC), heat dissipation within high-density enclosures can rise. Maintain a minimum clearance or use active ventilation if the ambient temperature inside the panel consistently exceeds 45 degC.

Commissioning & Wiring Tips

Always maintain strict physical separation between the blue intrinsically safe (Ex-i) field wiring and the non-intrinsically safe supply/alarm connections. Mixing these routing paths violates hazardous area compliance. Use shielded cabling for the control signals to minimize high-frequency noise interference in high-transient environments.

Installation Guidelines

CRITICAL WARNING

Isolate and de-energize all power sources before mounting, wiring, or configuring this module. Ensure the surrounding atmosphere is verified as non-hazardous (gas-free) before opening any protective enclosures or adjusting field connections.

1

Snap the module securely onto a standard TS 35 DIN rail, ensuring the grounding spring makes solid contact with the rail.

2

Connect the 19.2 to 31.2 V DC power supply to the designated non-Ex power terminals.

3

Wire the intrinsically safe valve/solenoid field devices to the blue Ex-i screw terminals, keeping the cables physically isolated from power lines.

4

Connect the alarm relay outputs to your supervisory PLC or safety system to monitor for voltage loss or device faults.

Loading product navigation…

What software is required to configure the ACT20X-2SDI-2HDO-S?

The module is configured using standard FDT/DTM software, which allows for precise parameter adjustments, diagnostic monitoring, and channel setup.

Can this module be used in explosive atmospheres?

Yes, the module is designed as an intrinsically safe (Ex-i) barrier, allowing it to safely interface with solenoids and valves located in hazardous areas.

What diagnostic functions are integrated into the 8965420000?

It features an integrated alarm function that triggers a relay output in the event of a supply voltage loss or an internal device error.

What is the step response time of this valve control module?

The module features a fast step response time of less than or equal to 10 milliseconds, ensuring rapid valve actuation.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...

Программирование циклов одноосевого движения на сервоприводе CMZ

В этом руководстве рассматривается, как встроенный ПЛК внутри серводрайвера CMZ SBD может выполнять автономные программы движения, включая логику поиска нуля, позиционное управление и циклическое...