1 จาก 3

ABB S201-B6 2CDS251001R0065 S200 Miniature Circuit Breaker

ABB S201-B6 2CDS251001R0065 S200 Miniature Circuit Breaker

  • Manufacturer: ABB

  • Product No.: S201-B6 2CDS251001R0065

  • Country of origin:สวีเดน

  • Product Type: Miniature Circuit Breakers

  • Payment: T/T, Western Union

  • Weight: 112g

  • Dimensions: 88 mm x 17.5 mm x 69 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The S201-B6 miniature circuit breaker with Product ID 2CDS251001R0065 is a single-pole, current-limiting safety device engineered to provide comprehensive overcurrent mitigation and short-circuit fault protection. As a core component of the System pro M compact S200 product range, this device features two distinct internal tripping mechanisms: a delayed thermal tripping configuration optimized for overload security and an electromechanical magnetic tripping assembly designed for instantaneous short-circuit protection. This circuit breaker is rated for a 6 A operational current and complies fully with major international standards including IEC/EN 60898-1, IEC/EN 60947-2, and UL1077, enabling seamless system compatibility across diverse residential, commercial, and heavy industrial automation environments.

Features

  • Incorporates a 1P single-pole configuration designed for space-saving terminal tracking and efficient distribution layout.
  • Utilizes a B-characteristic tripping curve calibrated for specific line and low-surge inductive application parameters.
  • Features an integrated contact position indicator with a clear visual window displaying Red for ON and Green for OFF states.
  • Outfitted with a failsafe bidirectional cylinder-lift screw terminal setup to optimize wiring stability and prevent installation errors.
  • Engineered for high modular versatility with full compatibility for bottom-fitting auxiliary contact installations and accessories.

Applications

  • Low-voltage electrical distribution boards and branch circuit panel assemblies.
  • Industrial control panels, manufacturing automation loops, and specialized machinery control networks.
  • Commercial building facility management grids and standard residential infrastructure protection loops.

Ordering Information

Parameter Value
Extended Product Type S201-B6 
Product ID 2CDS251001R0065 
EAN 4016779464901 

Technical Specifications

Parameter Specification
Manufacturer ABB 
Extended Product Type S201-B6 
Product ID 2CDS251001R0065 
Number of Poles 1P 
Number of Protected Poles
Tripping Characteristic
Rated Current (In) 6 A 
Input Voltage Type AC/DC 

 

Rated Operational Voltage

acc. to IEC 60898-1 230 V AC 

 

Rated Insulation Voltage (Ui)

acc. to IEC/EN 60664-1 440 V 
Rated Impulse Withstand Voltage (Uimp) 4 kV (5 kV at 2000 m / 6.2 kV at Sea Level) 
Dielectric Test Voltage 50/60 Hz - 1 min: 2 kV 
Rated Short-Circuit Capacity (Icn) (AC) 6 kA / (DC) 6 kA / (230/400 V AC) 6 kA 
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (133 V AC) 20 kA / (230 V AC) 10 kA / (24 V DC) 20 kA / (60 V DC) 10 kA / (230 V) 10 kA / (400 V) 10 kA 
Rated Service Short-Circuit Breaking Capacity (Ics) (133 V AC) 15 kA / (230 V AC) 7.5 kA 
Rated Conditional Short-Circuit Current (Inc) (230 V) 10 kA / (400 V) 10 kA 
Rated Frequency (f) 50/60 Hz 
Power Loss 2 W (2 W per Pole at Rated Operating Conditions) 
Housing Material Insulation Group II, RAL 7035 
Actuator Material Insulation Group II, Black, Sealable 
Actuator Type Toggle 
Contact Position Indication Red ON / Green OFF 
Energy Limiting Class
Electrical Endurance 20000 AC cycle 
Mechanical Endurance 20000 cycle 
Terminal Type Screw Terminals 
Screw Terminal Type Failsafe Bidirectional Cylinder-lift Terminal 
Connecting Capacity Busbar 10/10 mm² / Flexible with Ferrule 0.75 ... 25 mm² / Flexible 0.75 ... 25 mm² / Rigid 0.75 ... 35 mm² / Stranded 0.75 ... 35 mm² 
Tightening Torque 2.8 N-m 
Recommended Screw Driver Pozidriv 2 
Wire Stripping Length 12.5 mm 
Ambient Air Temperature Operation -25 ... +55 Celsius / Storage -40 ... +70 Celsius 
Degree of Protection IP20 (Enclosure with Cover IP40) 
Pollution Degree
Maximum Operating Voltage UL/CSA 60 V DC / 480Y/277 V AC 
Interrupting Rating acc. to UL1077 (277 V AC) 6 kA / (60 V DC) 10 kA / (120 V) 10 kA 
Connecting Capacity UL/CSA Busbar 18-8 AWG / Conductor 18-4 AWG 
Tightening Torque UL/CSA 18 in-lb 
Product Net Width 17.5 mm 
Product Net Height 88 mm 
Product Net Depth / Length 69 mm 
Product Net Weight 0.112 kg 

Installation Guidelines

  • DIN Rail Installation: Secure the unit firmly onto standard symmetrical tracking choices, including TH35-15 (35 x 15 mm mounting rail) or TH35-7.5 (35 x 7.5 mm mounting rail) according to the IEC 60715 standard.
  • Mounting Position: The underlying physical design permits installation and execution at any functional mechanical angle orientation.
  • Power Supply Connection: The architecture allows for arbitrary power supply connection placements based on structural needs.
  • Terminal Anchoring: Securely clamp the conductors inside the failsafe bi-directional cylinder-lift terminals with a Pozidriv 2 screwdriver to a certified torque of 2.8 N-m (18 in-lb for UL/CSA configurations).

Compliance and Certifications

  • Declaration of Conformity - CE: 2CDK403001D0607 
  • Declaration of Conformity - UKCA: 9AKK108467A5053 
  • Certification Agencies: EN, IEC, UL 
  • Standards: IEC/EN 60898-1, IEC/EN 60947-2, UL 1077

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB S201-B6 2CDS251001R0065 S200 Miniature Circuit Breaker

What standard visual cues does the device provide for terminal position updates?

The device features a mechanical contact position indication window that clearly shows Red for an ON status and Green for an OFF status.

What is the calibrated physical tightening torque for terminal connections?

The integrated screw terminals require an engineering tightening torque value of 2.8 N-m for standard industrial tasks or 18 in-lb for UL/CSA arrangements.

What internal mechanical protections are integrated into the device?

The device contains dual safety solutions: a delayed thermal tripping mechanism for overload mitigation and an electromechanical magnetic tripping system for short circuits.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สวีเดน

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...