1 จาก 1

Beckhoff EL4112-0010 EtherCAT Terminal 2-Channel Analog Output Module

Beckhoff EL4112-0010 EtherCAT Terminal 2-Channel Analog Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL4112-0010

  • Country of origin:เยอรมนี

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 65g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Engineered for precision industrial control loops, the EL4112-0010 analog output terminal generates standard electrical current signals in the range of -10 to +10 mA. This analog output terminal processes process data from the automation device with a high resolution of 16 bits (including sign) and transmits it with galvanic isolation directly to the field level. It features integrated Distributed Clocks (DC) support, allowing for highly synchronized, microsecond-level updates across EtherCAT networks.

The system features a 3-wire, single-ended connection technology, making it compatible with a wide array of industrial actuators, control valves, and system drives. With parameterized watchdog functionality and customizable user synchronization, this module delivers stable performance and safe-state fallback options for critical machinery systems.

Features

  • Provides two independent analog output channels with a current range of -10 to +10 mA.
  • Delivers high-precision digital-to-analog conversion at 16-bit resolution (including sign).
  • Supports EtherCAT Distributed Clocks (DC) with synchronization precision under 1 microsecond.
  • Includes short-circuit-proof outputs compatible with loads up to 500 Ohm.
  • Features integrated parameterizable watchdog state and user-activatable synchronization.
  • Constructed with a compact, rugged housing requiring only 12 mm of DIN rail width.

Applications

  • Closed-loop hydraulic and pneumatic valve positioning
  • Variable speed motor drive control systems
  • Distributed industrial process automation and telemetry
  • Power generation and turbine control auxiliary systems

Technical Specifications

Manufacturer Beckhoff
Part Number / Model EL4112-0010
Number of Outputs 2
Signal Current -10 to +10 mA
Resolution 16 bit (incl. sign)
Connection Technology 3-wire, single-ended
Power Supply 24 V DC via power contacts
Current Consumption E-bus typ. 160 mA
Current Consumption Power Contacts typ. 15 mA + load
Process Image Bit Width 2 x 16 bit AO output
Maximum Output Rate 15 ksps
Load < 500 Ohm (short-circuit proof)
Measuring / Output Error < +-0.1% (relative to end value)
Electrical Isolation 500 V (E-bus / signal voltage)
Distributed Clocks Yes (precision << 1 microsecond)
Housing Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight approx. 65 g
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20

Connections and Interfaces

Connection Type Conductor Cross-Section AWG Range Stripping Length
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
With Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16 8 to 9 mm

Installation Guidelines

  • Mount vertically onto standard 35 mm DIN rails conforming to EN 60715.
  • Ensure lock connection is engaged correctly during side-by-side terminal configuration via the integrated double slot-and-key system.
  • Use a standard screwdriver to actuate the spring-clamp terminals when routing field wiring.
  • Avoid installing in environments exceeding 95% non-condensing relative humidity.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

What is the primary function of the Beckhoff EL4112-0010?

The Beckhoff EL4112-0010 is a 2-channel analog output terminal designed to output precise current signals ranging from -10 to +10 mA with 16-bit resolution.

Does the EL4112-0010 support synchronized EtherCAT operations?

Yes, it supports EtherCAT Distributed Clocks (DC), enabling highly synchronized output updates with a system precision of under 1 microsecond.

What is the maximum current load for the power contacts on this terminal?

The maximum current load capability of the power contacts on the EL4112-0010 is 10 A.

What is the protection rating and mounting method for this device?

The module features an IP20 protection rating and is designed for direct mounting onto standard 35 mm DIN rails (EN 60715).

Is the EL4112-0010 certified for hazardous industrial locations?

Yes, the terminal is ATEX-certified with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...