1 จาก 3

Bently Nevada 990-16-XX-01-CN 106M1675-01 2-Wire Vibration Transmitter

Bently Nevada 990-16-XX-01-CN 106M1675-01 2-Wire Vibration Transmitter

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 990-16-XX-01-CN 106M1675-01

  • Country of origin:สหรัฐอเมริกา

  • Product Type: 2-Wire Vibration Transmitter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 460g

  • Dimensions: 10cm x 7.3cm x 6cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

 

Description

The Bently Nevada 990-16-XX-01-CN (Internal Part Number: 106M1675-01) is a high-performance, loop-powered 2-wire vibration transmitter engineered to provide continuous, standalone machinery protection. This field-rugged industrial instrument integrates the functionality of a proximity sensor and transmitter into a single circuit block, converting proximity probe input directly into a industry-standard 4-24 mA analog current loop signal proportional to overall shaft vibration. The 990-16-XX-01-CN 106M1675-01 accepts dynamic electrical signals from a standard proximity probe array and processes raw peak-to-peak displacement, delivering an immediate output stream to local programmable logic controllers (PLCs), distributed control systems (DCSs), or SCADA platforms. Designed with safety-critical and space-restricted machinery skids in mind, it interfaces with external measurement loops without requiring an intermediate proximitor sensor housing. It features physical terminal integration supporting a 4-20 mA current output loop, separate dynamic voltage output points for portable vibration analyzers, and special hardware certification variants for localized control markets.

Features

  • Integrated 2-wire transmitter design providing a direct 4-20 mA proportional current output path without intermediate signal conditioners.
  • Dynamic voltage output terminal provisioning real-time raw proximity waveforms directly to field analyzers.
  • Robust electrical isolation and solid-state encapsulation to eliminate electrical noise interference inside tight machine enclosures.
  • Seamless host system integration linking directly with any control interface featuring standard analog current input blocks.
  • Designed for high-reliability vibration tracking across thin fluid-filmed bearing shells and rotating shaft assemblies.

Applications

  • Continuous radial vibration and casing displacement tracking on centrifugal air and process gas compressors.
  • Critical machinery safety loops on high-speed industrial fans, cooling pumps, and fluid-handling blowers.
  • Standalone balancing and predictive maintenance monitoring across small-scale power generation turbines.

Ordering Information

Detail Product Ordering Reference
Base Model Designation 990 (2-Wire Vibration Transmitter)
Full Assembly Code 990-16-XX-01-CN
Internal Factory Reference 106M1675-01
Full Option Suffix Code Block -16 (System Full-Scale Range Option)
  -XX (Variable Options Selection Suffix)
  -01 (Mounting Hardware Base Option)
  -CN (Regional Specific Certification / Approval Suffix)

Technical Specifications

Parameter Detail
Manufacturer Bently Nevada (Baker Hughes)
Model Designation 990-16-XX-01-CN
Internal Part Number 106M1675-01
Transmitter Product Type 2-Wire Proximity Vibration Transmitter
Electrical Interface Profile Loop-powered current loop circuit
Analog Output Signal 4-20 mA DC proportional to overall peak-to-peak vibration displacement
Dynamic Waveform Interface Buffered voltage output terminal for local analyzer plug-in
System Power Input Range Nominal 24 VDC external supply loop
Signal Input Compatibility Non-contacting proximity transducer probe assembly
Chassis Assembly Suffix CN Certified Configuration Variant
Mounting Envelope Selection 01 Mounting Configuration
Hardware Core Dimensions Compact low-profile surface mount footprint
Chassis Mechanical Envelope Anodized aluminum housing with integrated terminal strips
Operational Weight Reference Industrial standard field transmitter assembly weight

Connections/Interfaces

Terminal Point Designation Terminal Function Assignment
+ / Loop Positive DC Loop Voltage Input Supply / Signal Connection
- / Return Negative Return / Current Loop Signal Output Connection
BUF / Dynamic Dynamic Raw Voltage Output Signal Point (For portable vibration meters)
COM / Ground Common Circuit Ground reference terminal line
Probe Input Dedicated connection terminal block input for external proximity probe lead

Installation Guidelines

  • Surface Chassis Mounting: Fix the transmitter block securely onto a clean, unpainted, vibration-isolated instrument panel inside an electrical enclosure. Verify proper physical layout alignment to prevent internal structural stress.
  • Proximity Probe Connection: Direct the primary proximity transducer coaxial lead wire straight into the designated input terminal channel block. Keep the internal signal wires separate from any high-voltage motor electrical conduits.
  • Loop Power Verification: Check the overall loop resistance parameters and source power input ratings before energizing the 4-20 mA current network lines to avoid unexpected component strain.
  • Dynamic Terminal Shielding: Ensure the dynamic voltage output terminal covers are completely sealed when not hooked up to local portable instruments to keep moisture and dust off the diagnostic contacts.

Does this 2-wire vibration transmitter require a separate external Proximitor sensor unit to function?

No. The transmitter integrates signal processing directly, converting probe input straight into a 4-20 mA current loop without an intermediate Proximitor sensor box.

What is the specific purpose of the buffered output terminal located on the front faceplate?

The buffered output provides the raw, unconditioned dynamic voltage waveform directly from the probe, allowing technicians to connect portable analyzers for diagnostic assessment.

What does the 'CN' suffix indicate at the tail end of this Bently Nevada part number string?

The 'CN' suffix indicates a specific regional certification configuration option package tailored for industrial control deployment standards.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา
Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...