1 จาก 1

Danfoss 131L9870 Frequency Converter VLT HVAC Drive FC 101

Danfoss 131L9870 Frequency Converter VLT HVAC Drive FC 101

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 131L9870

  • Country of origin:สหรัฐอเมริกา

  • Product Type: FC-101P15KT4E20H4

  • Payment: T/T, Western Union

  • Weight: 9000g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The Danfoss 131L9870 (FC-101P15KT4E20H4) is a specialized variable frequency drive engineered for high-efficiency motor control in commercial HVAC systems. Rated at 15 kW / 20 HP, this drive is designed to optimize the operation of ventilation fans, pumps, and cooling tower equipment. By providing precise, intelligent speed regulation, the 131L9870 (FC101P15KT4E20H4) minimizes energy waste and suppresses mechanical stress during startup, directly reducing total operational costs and mitigating the risks associated with unscheduled system downtime in critical building infrastructure.

Technical Configuration

This unit is optimized for three-phase power systems operating between 380 and 480 VAC. The architecture features an IP20-rated enclosure designed for cabinet-mounted applications, ensuring reliability in climate-controlled environments. A key technical feature of this model is the integrated H4 RFI filter (Class A1/C2), which provides robust electromagnetic interference suppression, ensuring compliance with strict EMC standards in commercial installations. The drive utilizes advanced control loops to maintain energy-efficient operation under fluctuating demand, making it an essential component for modern, high-performance HVAC systems.

Technical Specifications

Feature Specification
Model 131L9870
Drive Type VLT HVAC Drive FC 101
Power Rating 15 kW / 20 HP
Mains Voltage 380 to 480 VAC
Phases 3-Phase
Enclosure Rating IP 20
RFI Filter Class A1 (C2)
Net Weight 7.9 kg
Shipping Weight 9 kg

FAQs

What is the advantage of the H4 RFI filter in this model?

The H4 RFI filter (Class A1/C2) significantly reduces electromagnetic interference emitted by the drive. This is crucial for commercial building environments where the drive shares a power supply with sensitive electronic equipment, medical instrumentation, or communications hardware.

Can this drive handle sudden load changes in pump applications?

Yes, the FC 101 series is designed to handle the dynamic load profiles common in pump and fan applications. Its internal logic compensates for pressure changes rapidly, preventing motor stalling while maintaining process stability.

Is the IP20 enclosure suitable for mechanical rooms with dust?

IP20 provides basic protection against solid objects but does not protect against dust ingress or moisture. If the mechanical room has high dust accumulation or potential for humidity, the drive must be installed inside a sealed, filtered control cabinet to prevent internal component degradation.

How do I verify if the drive has faulted?

The drive features an integrated keypad and display interface. In the event of a trip, the display will show an alarm code. Consult the operator's manual to cross-reference the code with the specific hardware or load-side condition that triggered the safety shutdown.

Installation Guidelines and Maintenance

  • Thermal Management: Given the 15 kW power rating, heat dissipation is critical. Ensure that the cabinet installation allows for a minimum of 100 mm of clearance above and below the unit. Use high-performance exhaust fans to maintain the cabinet internal temperature below 45 deg C to maximize the lifespan of the internal capacitors.
  • Grounding Requirements: To ensure EMC compliance and operator safety, use a low-impedance connection from the drive chassis to the main equipment grounding bar. Use shielded motor cables and ensure the shield is terminated to the drive's ground terminal using a 360-degree conductive clamp.
  • Capacitor Maintenance: The internal DC-link capacitors are susceptible to aging if the drive remains powered down for extended periods. If the unit has been stored for more than 24 months, it is recommended to perform a controlled power-up procedure to reform the capacitors before applying full load.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา
Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...