1 จาก 3

GE Field Control IC670ALG630 Thermocouple Input Module

GE Field Control IC670ALG630 Thermocouple Input Module

Only 10 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC670ALG630

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Thermocouple Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 380g

  • Dimensions: 135 x 45 x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The GE IC670ALG630 (IC670ALG630) is a high-performance 8-channel analog input module designed for the GE Field Control decentralized I/O systemThis specialized module accepts 8 independent thermocouple or millivolt inputs, providing precise temperature monitoring for critical industrial processes such as power generation, chemical refining, and metal processingBy converting analog thermal signals into a 16-bit digital format (15 bits plus sign), the IC670ALG630 ensures high-resolution data acquisition, which is essential for maintaining system stability and reducing energy-intensive thermal fluctuations. Its ability to interface directly with various thermocouple types without external converters makes it a cost-effective solution for large-scale distributed temperature sensing.

Technical Configuration

The module architecture is built around a solid-state, optically-coupled multiplexer and an internal microprocessor that handles scaling, linearization, and advanced diagnostics.

  • Input Versatility: Supports a wide range of thermocouples including Types J, K, T, E, S, R, B, N, G, C, D, and Platinel II.
  • Cold Junction Compensation (CJC): Offers four flexible methods—Local (via thermistor), Remote (via BIU), Fixed (configured value), or None.
  • Data Processing: Features self-calibration at power-up and every minute thereafter to compensate for ambient temperature shifts.
  • Intelligent Diagnostics: Automatically detects and reports open thermocouple circuits, over-range/under-range conditions, and high/low alarm levels for each channel.
  • Configurable Sampling: Users can select data acquisition rates based on 50 Hz or 60 Hz line frequencies to optimize normal mode noise rejection

Technical Specifications

Attribute Specification
Model

IC670ALG630


Brand GE (General Electric)
Series

Field Control


Module Type

Thermocouple Analog Input


Number of Channels

8 (Individually configurable)


Resolution

15 bits + sign


Origin USA
Weight 0.38 kg
Dimensions 135 x 45 x 100 mm
Operating Temp

0 to 55 deg C ambient


Power Consumption

195 mA maximum from BIU


Isolation

1500 VAC (Input to Logic/Frame Ground)


Scan Time (60 Hz)

Approximately 60 ms per point


Technical FAQs

How is data reported in the PLC memory?

Each channel can be configured to report either linearized temperature (in tenths of degrees Celsius or Fahrenheit) or raw millivolt values (reported as 1/100 of a millivolt).

What happens if a sensor wire breaks during operation?

Unless suppressed in the configuration, the module performs an "Open Thermocouple" check every time a channel is readIf a break is detected, a diagnostic bit is set in the discrete input table, and further processing of that channel is halted to prevent false readings.

Can this module operate without a separate power supply?

Yes, this module does not require a separate field power supply; it draws its required operating current (up to 195 mA) directly from the Bus Interface Unit (BIU) backplane.


Engineering & Installation Guide

  • Cold Junction Accuracy: To ensure maximum precision when using local compensation, use the Thermocouple Terminal Block (IC670CHS004)If using standard terminal blocks, a 10K Ohm BetaTHERM thermistor must be installed at the terminals to avoid erroneous temperature reporting.
  • Thermal Management: Avoid installing the IC670ALG630 and its terminal blocks in the same cabinet as high heat-dissipation assembliesTemperature transients near the terminal connections can introduce CJC errors; maintaining a stable ambient environment is key to the +/-0.25 deg C CJC accuracy.
  • Noise Mitigation: The module provides 120dB of Common Mode Rejection. For best results, use shielded thermocouple extension wire and terminate the shield at the terminal block ground. Ensure the DIN rail is properly grounded to chassis ground to facilitate the assembly’s internal grounding path.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Field Control IC670ALG630 Thermocouple Input Module

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ
Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...