GE IS200EPCTG1AAA Mark VI Exciter PT/CT Board

GE IS200EPCTG1AAA Mark VI Exciter PT/CT Board

Only 6 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS200EPCTG1AAA

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Exciter PT/CT Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 850g

  • Dimensions: 260 mm x 20 mm x 160 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The IS200EPCTG1AAA operates as a specialized instrumentation interface board within the excitation control system loops paired with the GE Mark VI Speedtronic turbine control platform. This non-VME rack-mounted printed circuit board acquires low-level current and voltage waveforms directly from generator instrument transformers, converting analog utility parameters into standardized signal bands for core excitation loop regulation.

The primary function of the IS200EPCTG1AAA centers on isolating and conditioning raw potential transformer (PT) voltages and current transformer (CT) currents. By housing multiple physical magnetic transformers directly on the card assembly, it steps down primary power grid dynamics into proportional logic-level registers without routing high-voltage surges into internal digital processor networks. The hardware features three terminal blocks on the front edge and three vertical pin headers on the rear to interconnect field transformer wiring with core regulation buses. It enables the excitation control loop to execute instantaneous voltage adjustments, tracking synchronization angles and current phases to maintain active machine stability across large power plant operations.

Features

  • Dual Three-Phase PT Voltage Inputs: Accepts 2 three-phase voltage inputs dedicated to monitoring generator potential transformer lines.
  • Dual CT Current Sensing Channels: Equipped with 2 dedicated current transformer signal inputs to measure active electrical current loads.
  • Onboard Transformer Isolation: Features 2 integrated toroidal transformers and 4 frame-mounted isolation transformers to safely decouple field inputs.
  • Comprehensive Diagnostic Test Nodes: Built with 12 onboard hardware test points and a physical jumper switch to streamline engineering fault diagnosis.

Applications

  • Generator Excitation Loop Sensing: Installed within generator exciter enclosures to continuously track phase and voltage magnitudes on active distribution lines.
  • Turbine Power Synchronization Control: Supplies real-time grid and terminal parameters to the Mark VI control loop for balancing utility turbine output.
  • Industrial Utility Infrastructure Protection: Conditions line currents and potential loops to verify structural operating thresholds on heavy power grids.

Technical Specifications

Parameter Specification
Manufacturer GE Energy (General Electric)
Model IS200EPCTG1AAA
Product Series Mark VI Speedtronic / EX2100 Series
Module Type Exciter PT/CT Board
Generator PT Inputs 2 Three-Phase Inputs
Generator CT Inputs 2 Current Inputs
Analog Inputs 1 Channel
Front Terminal Configuration One 24-position strip, Two 4-position strips
Rear Rear Connector Pins J315, J305, J308 Vertical Connectors
Onboard Transformers 2 Toroidal Transformers, 4 Frame-Mounted Transformers
Overvoltage Protection Metal Oxide Varistors (MOVs)
Hardware Revisions 3 Revisions Total (2 Functional, 1 Artwork)
Mounting Form Factor Normal PCB Assembly (Lacks VME metallic faceplate)
Country of Origin USA

Connections/Interfaces

Connector Label Function
Front Terminal Strip 1 24-Position Signal Terminal Blocks
Front Terminal Strip 2 4-Position Field Input Block
Front Terminal Strip 3 4-Position Field Input Block
J315 Vertical Pin Backplane/Interconnect Connector
J305 Vertical Pin Backplane/Interconnect Connector
J308 Vertical Pin Backplane/Interconnect Connector

Installation Guidelines

  • Main Enclosure De-energization: Disconnect and completely isolate all primary voltage connections, auxiliary power distribution networks, and CT secondary links before attempting manual service or board extraction.
  • Electrostatic Charge Mitigation: Technicians must secure an approved, fully grounded anti-static ESD wrist strap during the entire installation process to prevent capacitive damage to onboard capacitors and instrumentation lines.
  • VME Rack Restriction: Do not attempt installation inside standard VME slots; this board lacks a standard metallic installation faceplate and must be mounted on designated internal baseplate standoffs.
  • Field Terminal Retention: Slide raw wiring into the front terminal strips evenly, clamping the wire screws down firmly to avoid open-circuit conditions on vital current transformer lines under plant vibration.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE IS200EPCTG1AAA Mark VI Exciter PT/CT Board

Can the IS200EPCTG1AAA board be mounted directly into a standard VME rack slot?

No. The board is designed as a normal card assembly that lacks a metallic structural faceplate, making it unsuitable for direct VME rack channel mounting.

What types of generator transformer inputs does this board accept?

The board features two three-phase potential transformer (PT) voltage inputs, two current transformer (CT) current inputs, and a single analog input.

Are the three total hardware revisions for this product completely identical?

No. The three-fold revision table includes two functional product modifications and a single artwork configuration change, though all maintain backwards-compatibility across the first two versions.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีเขียว
Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...