1 จาก 3

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

Only 6 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: SR745-W3-P511-G51-HI-R-E

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Transformer Protection System

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 8500g

  • Dimensions: 220 mm x 275 mm x 300 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The GE Multilin 745-W3-P511-G51-HI-R-E is a digital, three-winding transformer protection system engineered for the primary protection, management, and control of power transformers. This high-performance device delivers comprehensive multi-winding differential protection, adaptive harmonic restraint, and extensive overcurrent protection elements within a rugged draw-out construction. It features advanced internal logic and precise high-accuracy metering to eliminate the need for extra external components or auxiliary transducers. The unit is configured with 5 A phase current inputs and 5 A ground current inputs across its winding interfaces to match specific system requirements. Outfitted with high-speed processing, comprehensive data logging, and flexible communication ports, the device interfaces seamlessly with distributed control systems (DCS) and SCADA automation architectures to monitor asset health and maintain system integrity.

Features

  • Comprehensive three-winding transformer differential protection with percentage restraint and adaptive harmonic blocking.
  • Draw-out chassis construction allowing quick unit replacement and drastically reduced system maintenance downtime.
  • Integrated high-accuracy metering functions for current, voltage, power, and frequency parameters without auxiliary equipment.
  • Advanced fault diagnostics incorporating precise sequence-of-events reporting, oscillography, and waveform capture.
  • Multiple user-programmable analog and digital inputs/outputs for extensive control and interlocking logic schemes.
  • High-speed communications supporting industrial protocols for integration into SCADA networks.
  • FlexLogic programming capabilities allowing users to customize control sequences and interlocking logic without extra hardware.
  • Front-panel enhanced user interface with an informative LCD screen and tactile keypad for straightforward configuration and diagnostic readout.

Applications

  • Primary protection and control for three-winding power transformers in utility and industrial substations.
  • Main or backup differential and overcurrent protection for auto-transformers and multi-winding generation transformers.
  • Comprehensive asset monitoring, load profiling, and transformer thermal overload tracking in power networks.
  • Advanced power system automation requiring high-speed network reporting and protective relay interlocking.

Ordering Information

Selection Code Technical Specification Description
745 Base model for Transformer Protection System
W3 Three-Winding Transformer Protection
P511 5 A Phase Current Inputs (Winding 1, Winding 2, Winding 3)
G51 5 A Ground Current Inputs (Winding 1, Winding 2)
HI 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz Power Supply
R Red Breaker Closed LED Indicator
E Enhanced Display, Larger LCD, and Improved Keypad

 

Technical Specifications

Parameter Specification
Manufacturer GE Multilin (GE Vernova)
Transformer Windings (W3) 3 Windings
Phase Current Inputs (P511) 5 A for all three windings
Ground Current Inputs (G51) 5 A for Winding 1 and Winding 2
Power Supply Option (HI) 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz
Breaker Status LED (R) Red breaker closed LED indicator
User Interface (E) Enhanced display, larger LCD, and improved keypad layout

Installation Guidelines

  • Chassis Mounting: Securely mount the draw-out chassis into the instrument panel cutout using standard hardware guidelines designated for the unit frame.
  • Grounding Protocols: Connect a dedicated, low-impedance grounding copper wire directly to the chassis ground terminal to mitigate electrical noise and protect sensitive circuitry.
  • Wiring Requirements: Route current transformer (CT) and voltage transformer (VT) connections isolated from low-voltage signal wiring and communication lines to mitigate EMI/RFI issues.
  • CT Circuit Integrity: Ensure all phase and ground current transformer secondary circuits are fully verified and safely terminated to the correct rear blocks prior to operational power-up.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

What is the function of the W3 designation in the relay model code?

The W3 designation specifies that the device is configured to support comprehensive primary differential and overcurrent protection for a three-winding power transformer.

What input current ratings do the P511 and G51 options provide?

The P511 option provides 5 A phase current inputs for all three transformer windings, while the G51 option provides 5 A ground current inputs for Winding 1 and Winding 2.

What source voltage limits are supported by the HI power supply option?

The HI power supply option operates safely over an input range of 88 to 300 VDC and 70 to 265 VAC at a frequency of 48 to 62 Hz.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ
Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...