1 จาก 3

GE Multilin UR-8NH Standard 8CT With Enhanced Diagnostics

GE Multilin UR-8NH Standard 8CT With Enhanced Diagnostics

Only 7 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-8NH

  • Country of origin:แคนาดา

  • Product Type: Multilin UR Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 8.2cm x 12.2cm x 6cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The GE Multilin UR-8NH Standard 8CT with enhanced diagnostics is a modular component designed for the Universal Relay (UR) platform, specialized for transformer, transmission line, and substation protection management. This specific hardware assembly couples the 8N current transformer (CT) input module with the H high-voltage universal power supply module within a heavy-duty automation chassis. The 8N module offers 8 independent current transformer inputs engineered with enhanced diagnostics to continuously verify internal digital signal processor paths and safeguard external CT circuit connectivity against undetected open-circuit faults. Operating as a core analog measurement and power management unit, the GE Multilin UR-8NH Standard 8CT with enhanced diagnostics interfaces seamlessly with updated protective processing cores to deliver real-time telemetry, oscillography, and high-speed protection routing across industrial electrical systems.

Features

  • Continuous Input Verification: Integrated enhanced diagnostics within the 8N module continuously monitor internal hardware health and analog-to-digital signal path status.
  • High-Density CT Monitoring: Provides 8 separate current transformer inputs optimized for comprehensive three-phase and neutral current telemetry.
  • Universal Power Architecture: Equipped with the H power supply module designed to tolerate a wide input range across both AC and DC auxiliary power networks.
  • Blue-Label Alignment Warning: Features blue color-coded physical labeling to guarantee correct hardware compatibility with corresponding high-performance CPU architectures.
  • Advanced Transient Recording: Facilitates data routing for high-capacity event recording and non-volatile oscillography storage.

Applications

  • Utility and primary substation transformer protection.
  • Transmission line and feeder management distribution networks.
  • Industrial power distribution automated switchgear configurations.
  • Substation automation schemes interfacing via high-speed communication networks.

Ordering Information

Suffix Code Description
8N Standard 8CT with enhanced diagnostics 
H 125 / 250 V AC/DC power supply 

Technical Specifications

Parameter Specification
Manufacturer GE Multilin 
Country of Origin Canada / USA 
Module System Type Universal Relay (UR) Series Platform 
CT Configuration Suffix 8N (Standard 8CT with enhanced diagnostics) 
Power Supply Suffix H (125 / 250 V AC/DC power supply) 
Current Metering Accuracy ±0.25% of reading or ±0.1% of rated at 0.1 to 2.0 x CT rating 
Diagnostic Triggers Hardware watchdog, DSP mismatch check, circuit fault states 
Event Recorder Capacity Up to 1024 events time-tagged to 1 microsecond accuracy 
Oscillography Records Maximum 64 records stored in non-volatile memory 
Operating Temperature -40 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 5% to 95% non-condensing

Installation Guidelines

Panel Mounting

Mount the chassis containing the modules securely inside a standard 19-inch equipment rack system or a designated panel cutout. Verify that the structural framework supports the collective weight of the populated unit and heavy-gauge rear terminal wiring harnesses.

Grounding

Establish a secure grounding path from the rear-chassis grounding stud to the main station ground busbar. Use a low-impedance copper wire with a minimum gauge of 10 AWG (or 4.0 mm square), ensuring all non-conductive coatings or paint are scraped away at the terminal junction point.

CT Terminal Connections

All secondary lines coming from external current transformers must pass through an dedicated external shorting block mechanism before connecting to the rear terminal blocks of the unit. Never clear or open-circuit an active CT secondary circuit. Use proper ring-tongue terminal lugs and copper conductors rated for 90 degC or higher.

CPU Module Alignment

The 8N module utilizes modern blue labeling characteristics. Ensure it is exclusively paired with matching blue-labeled central processing units (including variants 9E, 9G, 9H, 9J, 9K, 9L, 9M, 9N, 9P, 9R, or 9S) to prevent physical hardware mismatches or critical system faults.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin UR-8NH Standard 8CT With Enhanced Diagnostics

What happens if an 8N module is mistakenly paired with an older 9A, 9C, or 9D CPU module?

The new 8N CT modules with enhanced diagnostics are strictly incompatible with older CPU series. If a mismatch occurs, the relay will fail to initialize and will generate a DSP ERROR or HARDWARE MISMATCH system fault.

What is the physical indication used to verify hardware compatibility during installation?

Compatible modules feature distinctive blue-colored identification labels on their physical framing accompanied by warning stickers indicating that both the CPU and DSP module label colors must match.

Does the H suffix power supply accept both alternating and direct currents?

Yes, the H suffix power supply is a universal high-voltage module engineered to operate efficiently across standard nominal 125 V AC/DC and 250 V AC/DC power networks.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ
Country of origin
แคนาดา
Power source
ใช้พลังงานไฟฟ้า ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...