1 จาก 3

General Electric IS220PSFDH1A Mark VI Speedtronic Flame Detector Power Supply Pack

General Electric IS220PSFDH1A Mark VI Speedtronic Flame Detector Power Supply Pack

Only 2 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS220PSFDH1A

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Power Supply Pack

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 380g

  • Dimensions: 12.8cm x 8.2cm x 6cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The IS220PSFDH1A is a specialized Flame Detector Power Supply pack manufactured by General Electric as part of the Mark VI Speedtronic Turbine Control System Series. This modular assembly is engineered to provide reliable, high-voltage electrical excitation directly to the flame detector circuits located on the primary gas turbine trip protection board (TRPG). Acting as a critical link within the turbine safety and flame monitoring infrastructure, the IS220PSFDH1A interfaces seamlessly through physical hardware connections to drive active optical sensors and ensure deterministic feedback verification. The base printed circuit board is protected comprehensively with a chemically-applied conformal coating layer, ensuring resilience against airborne contaminants and harsh ambient environments typical of industrial power generation facilities.

Features

  • Integrated Group 1 Mark VI series modular architecture designed for high-reliability turbine trip safety integration.
  • Fully passive convection-cooled hardware layout completely eliminating failure-prone mechanical cooling fans.
  • Exhaustive, thin layer of chemically-applied conformal PCB coating to mitigate risks of oxidation and atmospheric tracing.
  • Equipped with three dedicated faceplate diagnostic LEDs (one red, two green) indicating precise module operational states and active internal functional faults.
  • Features a factory-configured, pure solid-state design requiring no manual jumper switches or hardware setting adjustments.

Applications

  • Gas turbine optical flame detection monitoring loops within Speedtronic power systems.
  • Centralized turbine protection arrays coupled directly to TRPG safety trip boards.
  • Alternative energy infrastructures and legacy wind-power automation platforms built upon Mark VI network backbones.

Technical Specifications

Parameter Specification Value
Manufacturer General Electric
Part/Model Number IS220PSFDH1A
Functional Abbreviation PSFD
Product Series Mark VI Speedtronic
Assembly Classification IS220 Special Assembly (Group 1 Layout)
Primary Functional Revision A (Alters baseline performance and electrical execution)
Maximum Input Voltage 29.4 V dc
Startup Operational Time 34 mS (At full load with 28 V dc input source)
Full-Load Power Consumption 4.1 W
Maximum Open-Circuit Output Voltage 355 V dc (At zero load with 29.4 V dc input)
Local Output Diagnostic Interface Differential pair TP test points
Physical Enclosure Geometry Rectangular industrial housing
Working Temperature Range -30 degrees Celsius to +65 degrees Celsius
Cooling Methodology Natural Convection (Fanless)
Country of Origin United States (Domestic GE Manufacture)

Connections and Interfaces

Interface Connection Function / Circuit Assignment
J3 Connector Flame detector power supply circuit link 1 to TRPG board
J4 Connector Flame detector power supply circuit link 2 to TRPG board
J5 Connector Flame detector power supply circuit link 3 to TRPG board
TP Test Points Differential hardware probe points for local output voltage verification
Faceplate IR Port Infrared port (Not used / Inactive in production assembly)

Application Pitfalls & Engineering Notes

Engineers should note that the internal step-up circuitry of this module generates high-voltage operational spikes reaching up to 355 V dc under zero-load conditions given a maximal input profile of 29.4 V dc. Ensure appropriate voltmeter instrumentation is set to withstand high-voltage ranges when troubleshooting local test points. The integrated infrared (IR) interface located on the front panel faceplate remains non-functional and must not be used for diagnostic calibration sequences.

Commissioning & Wiring Tips

When monitoring live operational parameters during start-up tracking loops, connect calibrated multi-meter leads carefully across the differential pair of TP test points. Given that this module outputs high potential within 34 milliseconds from full-load engagement, transient verification should be performed using storage-type digital oscilloscopes to correctly isolate output ripple factors or installation tracking noise.

Installation Guidelines

CRITICAL WARNING:

This device generates open-circuit potential up to 355 V dc. Disconnect and verify absolute zero energy on all primary DC input networks before handling interface modules or tracking structural wires. Touching active connections will result in severe electrical shock injuries or immediate card short-circuit failure.

1

Mount the rectangular pack assembly directly above the TRPG (primary gas turbine trip protection board) on a stable sheet metal surface structure.

2

Secure the assembly base mechanical layout using specified mounting studs, mounting brackets, and the designated mounting plate to limit physical shock deformation.

3

Firmly couple the primary power routing interfaces into connectors J3, J4, and J5 on the TRPG board to establish complete signal path paths for the flame detection array.

What is the maximum output voltage generated by this power pack under open-circuit conditions?

When the pack operates with zero load and receives an input potential of 29.4 V dc, it can generate an open-circuit output voltage reaching up to 355 V dc.

How fast does the power pack initiate full hardware operation upon startup?

The module features a startup duration of precisely 34 milliseconds when executing under full-load conditions with an input configuration of 28 V dc.

Through which hardware intersections does the pack connect to the turbine safety system?

The assembly routes output power straight into the flame detector circuit located on the primary gas turbine trip protection board via interfaces J3, J4, and J5.

How can an engineer verify output voltage locally on an installed unit?

Output voltage levels can be monitored safely using a differential multimeter probe arrangement applied directly across the physical TP test points.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...