1 จาก 3

General Electric Mark VIe IS230TRLSH2B Relay Output Module

General Electric Mark VIe IS230TRLSH2B Relay Output Module

Only 7 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS230TRLSH2B

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Relay Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2920g

  • Dimensions: 34cm x 22.5cm x 11.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The General Electric IS230TRLSH2B is a specialized relay output terminal board module designed for the Mark VIe control system platform. This Relay Output Module interfaces with control processors to safely drive field solenoids, control valves, motor starters, and external interlock circuits across heavy industrial environments. Operating as a component within the distributed control architecture, it receives digital commands from the system controller and converts them into physical, isolated dry contact closures or voltage switching states. It is engineered specifically for system compatibility within large-scale utility and turbine control frameworks, providing robust physical separation between low-voltage microelectronic control loops and high-voltage field execution circuitry.

Features

  • Built for reliable physical and electrical galvanic isolation within the modular framework
  • Designed to accept high-speed logic state signals from upstream control layers
  • Equipped with rugged on-board relays configured for continuous operational duty
  • Features terminal block junctions directly on the board assembly for secure field loop routing
  • Integrates seamlessly with multi-channel architecture to minimize cabinet hardware footprints

Applications

  • Distributed Control Systems (DCS) for gas, steam, and hydro turbine regulation
  • Solenoid valve control and auxiliary pump startup staging
  • Safety interlock processing and remote equipment trip circuits
  • Heavy industrial power plant, manufacturing, and critical system infrastructure automation

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Model Designation IS230TRLSH2B
System Series Mark VIe Control System
Module Type Relay Output Terminal Board Module
Country of Origin USA
Channel Configuration Multi-channel dedicated relay outputs
Enclosure / Mounting Panel or base assembly carrier layout
Operating Temperature 0 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Humidity Constraints 5% to 95% non-condensing relative humidity

Connections/Interfaces

Terminal Assignment Function
Screw Terminals (Field Side) Field device loop connections (Form-C or Form-A contacts)
I/O Pack Connector High-density multi-pin communication bridge to the primary controller
Shield Terminals Shield drain wire termination ground points for EMI containment

Installation Guidelines

Cabinet Orientation & Mounting

Secure the module onto its designated backplate or carrier structure inside the control cabinet. Ensure the mounting fasteners are fully tightened to ground the underlying metal chassis panel and isolate the board from excessive high-frequency structural vibration.

Cable Shielding & Routing

Route all digital signal cables separate from heavy AC power lines to protect against inductive cross-coupling and electrical noise. Terminate field wire shields only at the specified system ground point on the board frame.

Connection Torques

When tightening the terminal block screws for field loops, torque them according to standard industrial terminal specifications to prevent loose contact junctions or intermittent continuity dropouts during thermal cycling.

What primary function does this board perform in the system?

The module operates as a relay output interface, receiving electronic logic commands from the controller and activating physical relay contacts to switch external field loads safely.

How should shield drain wires be terminated on this board?

Shield drain wires must be connected directly to the dedicated shield termination points provided on the module frame to secure effective path-to-ground noise mitigation.

What is the recommended storage temperature range for this module?

The safe storage temperature limit for this module spans from -40 degC to +85 degC under non-condensing atmospheric conditions.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...