1 จาก 3

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

Only 10 item(s) left in stock
  • Manufacturer: HIMA

  • Product No.: F3331

  • Country of origin:เยอรมนี

  • Product Type: Safety Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 140g

  • Dimensions: 2cm x 19cm x 12.8cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The F 3331 (F3331) is a high-reliability, 8-fold safety-related output module engineered by HIMA for use in critical control systems requiring Requirement Class AK 1 through 6. This module is a cornerstone in Safety Instrumented Systems (SIS) within the chemical processing, subsea, and pharmaceutical industries, where safe isolation and integrated shutdown capabilities are paramount. The F 3331 supports resistive and inductive loads up to 500 mA (12 W) and is specifically designed to prevent unintended output signals in the event of an L- supply break. By providing continuous automated testing and line monitoring, it ensures that your safety loops remain functional, significantly reducing the Risk Priority Number (RPN) of your automated assets.

Technical Configuration

The F 3331 is designed with a "testable" architecture, meaning it performs self-diagnostics without interrupting the process logic. Its safety DNA is built around three core pillars:

  • Integrated Safety Shutdown: Hardware-level circuitry ensures the module can reach a de-energized state upon demand or internal fault detection.

  • Comprehensive Test Routines: The module executes a "walking-bit test" to check for cross-talking and switching capability, alongside a read-back feature that monitors output signals (0-signal threshold ≤ 6.5 V).

  • Line Monitoring: The module actively supervises the connection to the field device, detecting short circuits (tripping between 0.75 and 1.5 A) and line breaks (monitoring current between 0.5 and 9.5 mA).

Technical Specifications

Attribute Specification
Model F 3331
Brand HIMA
Output Channels 8 Channels, Testable
Safety Requirement Class AK 1 to 6
Load Capacity (Resistive/Inductive) Up to 500 mA (12 W)
Lamp Load Capacity Up to 4 W
Internal Voltage Drop Max. 2 V at 500 mA
Short Circuit Protection Integrated (0.75 to 1.5 A)
Test Signal Duration Max. 200 microseconds
Space Requirement 4 TE
Power Consumption (5V DC) 130 mA
Power Consumption (24V DC) 180 mA (plus load current)
Operating Temp 0 to 60 deg C

Technical FAQs

How does the module handle a "0 signal" fault?

The read-back operating point for a 0-signal is ≤ 6.5 V. It is important to note that if a fault causes the voltage to rise but stay below this 6.5 V threshold, the system will not detect it as a high-level fault.

What happens if there is a break in the L- supply?

The F 3331 is designed so that no output signal is possible if the L- supply is broken, ensuring a fail-safe condition.

Is there a limit to the length of the field wiring?

Yes, the admissible line resistance (combined in and out) is a maximum of 11 Ohm. Exceeding this resistance can interfere with the module's ability to accurately monitor line breaks and short circuits.


Engineering & Installation Guide

  • Load Balancing and Heat Management: While the module is rated for 500 mA per channel, the total power dissipation at 24 VDC can reach 180 mA plus the combined load. Ensure the cabinet has adequate convection cooling, as excessive ambient heat (above 60 deg C) can shift component tolerances and affect the undervoltage tripping point (standardly ≤ 16 V).

  • Inductive Load Protection: For inductive loads, although the module is rated for 12 W, we recommend installing external flyback diodes at the load side for high-cycle applications to further protect the integrated safety shutdown circuitry from back-EMF spikes.

  • Test Signal Transparency: The test signal duration is extremely short (max. 200 microseconds). While this is transparent to most industrial actuators and lamps, ensure that any downstream high-speed electronic interfaces are compatible with this transient diagnostic pulse to avoid "flicker" or false triggering.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีเขียว
Country of origin
เยอรมนี
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...