Omron G9SX-ADA222-T150-RT G9SX Flexible Safety Unit

Omron G9SX-ADA222-T150-RT G9SX Flexible Safety Unit

Only 4 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: G9SX-ADA222-T150-RT

  • Country of origin:ญี่ปุ่น

  • Product Type: Flexible Safety Units

  • Payment: T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Facilitating scalable safety control in industrial automation environments, the Omron G9SX-ADA222-T150-RT serves as an advanced flexible safety unit. This high-performance module provides flexible expansion and precise safety output configurations to secure machinery and manufacturing personnel. It is engineered with a combination of instantaneous and time-delayed solid-state safety outputs, allowing for complex safety logic implementation without the need for a dedicated safety PLC.

The G9SX-ADA222-T150-RT features solid-state outputs using P-channel MOS FET transistors, offering exceptional durability and fast response times. It provides dual-channel safety inputs and supports off-delay configurations up to 150 seconds, making it ideal for systems requiring controlled deceleration or stop sequences before total power isolation. Equipped with screw terminals, this unit ensures secure electrical connections under high-vibration conditions.

Features

  • Advanced control logic safety module with flexible expansion capabilities.
  • Features 2 instantaneous safety outputs and 2 off-delayed safety outputs.
  • Provides 2 auxiliary outputs for diagnostics and PLC feedback integration.
  • Off-delay duration is adjustable up to a maximum of 150 seconds.
  • Utilizes solid-state P-channel MOS FET transistor outputs for wear-free, high-speed switching.
  • Removable screw terminal blocks (-RT designation) for simplified installation and maintenance.
  • Compact DIN-rail mountable housing optimizing control panel space.

Applications

  • Emergency stop monitoring circuits in automotive assembly.
  • Safety door and gate interlocking systems on packaging machinery.
  • Controlled deceleration stop sequences for heavy rotating machinery.
  • Robotic cell perimeter guarding and light curtain integration.
  • Material handling systems and conveyor safety management.

Technical Specifications

ManufacturerPart Number / ModelSeriesProduct TypeRated Supply VoltageOperating Voltage RangeRated Power ConsumptionSafety Input VoltageSafety Input ImpedanceInstantaneous Safety OutputsOFF-delayed Safety OutputsAuxiliary OutputsMax. OFF-delay TimeOutput Load Current (1 or 2 outputs)Output Load Current (3 or more outputs)Terminal Block TypeVibration ResistanceWeight
Omron
G9SX-ADA222-T150-RT
G9SX Series
Flexible Safety Unit (Advanced Unit)
24 VDC
-15% to 10% of rated supply voltage
4 W max.
20.4 VDC to 26.4 VDC
Approx. 2.8 kOhm
2 outputs (P-channel MOS FET)
2 outputs (P-channel MOS FET)
2 outputs (PNP transistor, 100 mA max.)
150 s
1 A DC max.
0.8 A DC max.
Screw terminals
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
0.2 kg

Installation Guidelines

To ensure optimal performance and safety compliance, mount the G9SX-ADA222-T150-RT on a standard 35 mm DIN rail inside an IP54 or higher rated control enclosure. Maintain adequate clearance around the unit's ventilation slots to prevent heat buildup. Always isolate the primary power supply before wiring the screw terminals. Use copper conductors rated for the maximum load currents specified. Connect the safety inputs and outputs in accordance with local safety standards and machinery directives to maintain the required safety integrity level (SIL).

What is the maximum OFF-delay time supported by the Omron G9SX-ADA222-T150-RT?

This unit supports an adjustable off-delay time up to a maximum of 150 seconds.

What does the -RT suffix signify in the part number?

The -RT suffix indicates that the safety unit is equipped with removable screw terminal blocks for simplified wiring and field replacement.

What are the load current capacities for the safety outputs?

The safety outputs support up to 1 A DC maximum when using 2 or fewer outputs, and 0.8 A DC maximum when using 3 or more outputs.

Can this safety module operate on an AC supply voltage?

No, the G9SX-ADA222-T150-RT requires a rated supply voltage of 24 VDC with an operating range of -15% to +10%.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
ญี่ปุ่น

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...