1 จาก 1

Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670

Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670

Only 8 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA32-0BF0

  • Country of origin:เยอรมนี

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 x 35 x 15 cm (Estimated)

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

This is a Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670, an industrial-grade human-machine interface (HMI) designed for machine-level control and visualization tasks. This unit features a 12-inch TFT touch display and is powered by a Pentium III 500 MHz CPU. It is configured with 256 MByte of RAM and a 20 GB hard drive, pre-installed with the Windows 98 operating system. The device operates on a 115-230 V AC power supply and is supplied with a U.S. mains cable.

Features

  • 12-inch TFT color display with integrated touch screen
  • Intel Pentium III processor operating at 500 MHz
  • 256 MByte of installed RAM
  • 20 GB internal hard drive for data and application storage
  • Pre-loaded with Windows 98 (English version)
  • Flexible power supply input of 115-230 V AC

Applications

  • Machine control and operation panels
  • Process visualization and SCADA clients
  • Industrial data acquisition and logging
  • Factory automation control interfaces

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6AV7612-0AA32-0BF0
Series SIMATIC Panel PC 670
Product Type Panel PC
Display 12-inch TFT Touch Display
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 256 MByte
Storage 20 GB Hard Drive (HD)
Operating System Windows 98 (English)
Input Voltage 115-230 V AC (Supplied with U.S. Mains Cable)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 45 x 35 x 15 cm (Estimated)

Installation Guidelines

CRITICAL WARNING: Risk of Electric Shock

Disconnect all power sources before installation, servicing, or removal. All work must be performed by qualified personnel in accordance with local and national electrical codes. Failure to comply can result in severe injury or death.

  1. 1
    Panel Preparation: Ensure the mounting cutout in the control cabinet or panel is clean, deburred, and matches the required dimensions for the PC 670. Verify that all mounting clamps and the sealing gasket are present and undamaged.
  2. 2
    Mounting: Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly in a diagonal sequence to ensure a uniform seal against the panel surface, maintaining the specified IP rating. Do not overtighten.
  3. 3
    Grounding and Power Connection: Connect the protective earth (PE) terminal to the cabinet's main ground point using a low-impedance conductor. Connect the 115-230 V AC mains supply to the power input terminals, observing correct polarity for line and neutral.
  4. 4
    Peripheral and Network Connections: Connect any required peripherals such as keyboards, mice, or external drives to the appropriate ports. Connect network cables to the Ethernet port(s) for communication with PLCs or other network devices.
  5. 5
    Final Checks and Power-Up: Verify all connections are secure and that there is adequate clearance for ventilation around the unit's rear. Close the cabinet door, restore power to the panel, and power on the Panel PC to begin system configuration.

What operating system is installed on the 6AV7612-0AA32-0BF0?

This Panel PC comes pre-installed with the English version of Windows 98.

What are the screen specifications for this SIMATIC Panel PC?

The unit is equipped with a 12-inch TFT color display that features an integrated touch screen for user input.

What is the processor and memory configuration?

It is configured with a 500 MHz Pentium III CPU and 256 MByte of RAM.

Is the 6AV7612-0AA32-0BF0 a current product?

No, this model is classified as an obsolete product, making it suitable as a spare part for existing legacy systems.

What is the required input voltage for this device?

The Panel PC supports a flexible input voltage range of 115-230 V AC and is supplied with a U.S. mains cable.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...