1 จาก 1

Siemens 6ES7710-3CA33-1FB2 SIMATIC Field PG Programming Device

Siemens 6ES7710-3CA33-1FB2 SIMATIC Field PG Programming Device

Only 4 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7710-3CA33-1FB2

  • Country of origin:เยอรมนี

  • Product Type: Industrial Programming Devices

  • Barcode: 85371099

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Dimensions: 50 cm x 40 cm x 20 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

The Siemens 6ES7710-3CA33-1FB2 is a rugged, portable programming device specifically engineered to survive industrial floor conditions during the commissioning, maintenance, and software lifecycle management of automation architectures. This dedicated SIMATIC Field PG platform bridges the gap between legacy and contemporary control layers by integrating an Intel Pentium III 850 MHz processor with 256 MB of internal SDRAM and an expanded 30 GB Enhanced IDE hard disk drive for system project storage. The device features pre-loaded engineering environments including STEP 7, STEP 5, and STEP 7 Micro/WIN software tools running on a stable Windows 2000 Multi-User Interface operating system, facilitating direct parameter modification and logical troubleshooting. Dual integrated hardware reader drives—a combination DVD/CD-ROM drive alongside a SuperDisk LS-240 drive—allow for flexible optical and magnetic data transfers without requiring external power adapters or peripheral conversion boxes in the field.

Key Features

  • Dual-Generation Communication Software: Built-in native support for legacy SIMATIC S5 (via STEP 5) and SIMATIC S7 (via STEP 7) programmable logic controllers.
  • Integrated Specialized Optical/Magnetic Drives: Built-in DVD/CD-ROM reading hardware combined with a high-capacity SuperDisk LS-240 drive for versatile field data extraction.
  • Industrial Floor Resilience: Housed within a ruggedized portable chassis designed to withstand physical vibration, dust, and electrical interference profiles common to plant environments.
  • Multi-Language Operating System Layer: Windows 2000 MUI pre-configured out of the box with localized system files for Germany, France, Netherlands, Spain, Belgium, and Austria.
  • Dedicated Processor Cache Topology: On-die 256 KB Level 2 cache layer optimizes real-time compile rates and transmission sequencing for micro-controller instructions.

Industrial Applications

  • On-site logic execution modification and firmware flashes for legacy SIMATIC S5 architectures.
  • Field commissioning and loop check validation of distributed SIMATIC S7 automation nodes.
  • Local database backups, runtime monitoring, and diagnostics of industrial assembly operations.
  • Service intervention, process network diagnostics, and software logic archiving by field service engineers.

Technical Specifications

Specification Category Parameter Variant Technical Value / Specification
General System Identity Manufacturer Siemens
Product Series Designation SIMATIC Field PG
Part Number / MLFB 6ES7710-3CA33-1FB2
Product Classification Type Field Programming Device
Lifecycle Status Phase-Out
Processing & Core Hardware Central Processor Unit Intel Pentium III
CPU Clock Frequency 850 MHz
Level 2 Hardware Cache 256 KB
System RAM Architecture 256 MB SDRAM (1x 256 MB physical module)
Primary Bulk Storage Capacity 30 GByte Hard Disk Drive
Storage Interface Standard EIDE (Enhanced IDE)
Media Drive Bays Optical Drive 1 DVD / CD-ROM Drive Combination Pack
Magnetic/Floppy Drive 2 SuperDisk LS-240 Multi-Format Drive
Software Environment Operating System Environment Windows 2000 MUI (GE / F / S / I Compatibility)
Pre-installed Software Stack STEP 7, STEP 5, STEP 7 Micro/WIN Engineering Suites
Electrical Connections Power Cord Mapping CEE 7/7 Grounded Plug (Germany, France, Netherlands, Spain, Belgium, Austria)
Logistics & Dimensions Country of Origin Germany
Net Unit Mass Weight 4.00 kg
Shipping Weight (Calculated) 5.50 kg
Package Dimensions (Calculated) 50.00 cm x 40.00 cm x 20.00 cm
International Commodity Code 85371099
ECCN Index N

Installation and Operational Guidelines

CRITICAL WARNING: EQUIPMENT INTERACTION PROTOCOL
Only personnel explicitly trained in Siemens legacy automation protocols and electrical plant safety must operate this programming unit. Prior to connecting communications physical lines (such as MPI or TTY lines) to target active PLCs, verify common plant earth grounding limits to negate potential cross-current damage to interface hardware registers.
1

Perform an exterior visual evaluation of the chassis, media slot doors, and grounding interface pins for debris or physical changes incurred during transport.

2

Connect the factory-supplied mains line power cord to the primary input socket and interface with an enterprise grounded AC outlet panel.

3

Depress the primary physical power button and wait for the internal POST diagnostics to clear and boot into the Windows 2000 multi-language user interface shell environment.

4

Execute the designated localized program platform (such as STEP 5 for SIMATIC S5 arrays or STEP 7 for S7 networks) matching target field equipment hardware requirements.

5

Securely engage the dedicated communication serial/parallel link cables between the engineering device and the controller station interface node before requesting online telemetry status or logic downloads.

Which software environments come pre-installed on this device?

The programming device comes factory loaded with STEP 7, STEP 5, and STEP 7 Micro/WIN, enabling diagnostic and modification support for legacy SIMATIC S5 and S7 hardware lines.

What legacy media configurations are available for moving control project profiles?

The platform contains an active combination DVD/CD-ROM storage drive alongside a localized high-density SuperDisk LS-240 magnetic drive bay for flexible file transfers directly at the control panel.

Is the integrated Windows 2000 environment customized for specific regional locations?

Yes, it features a Multi-User Interface configuration that includes regional language file support parameters mapped for Germany, France, Netherlands, Spain, Belgium, and Austria.

What processing chip forms the computational core of this Field PG?

The machine operates on an Intel Pentium III microprocessor clocked at 850 MHz with an integrated 256 KB Level 2 cache profile.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา
Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...