1 จาก 1

Weidmuller 1469480000 PRO ECO 120W 24V 5A Switch-Mode Power Supply Unit

Weidmuller 1469480000 PRO ECO 120W 24V 5A Switch-Mode Power Supply Unit

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: PRO ECO 120W 24V 5A

  • Country of origin:เยอรมนี

  • Product Type: Switch-Mode Power Supplies

  • Payment: T/T, Western Union

  • Weight: 675g

  • Dimensions: 40 mm x 125 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Engineered for reliable and space-saving power delivery in decentralized automation systems, the Weidmuller 1469480000 is a high-efficiency switch-mode power supply unit. Part of the robust PRO ECO series, this module delivers a regulated 24 V DC output at 5 A, providing a continuous 120 W of power. It features a wide-range input capable of accepting both AC and DC voltages, making it highly versatile for global industrial applications.

The unit is housed in a corrosion-resistant metal enclosure designed for TS 35 DIN rail mounting. It features an integrated potentiometer for output voltage adjustment, comprehensive diagnostic LEDs, and a floating status relay contact for remote monitoring. With built-in protection against overloads, short circuits, and over-temperature conditions, this power supply ensures high operational safety and system uptime in demanding environments.

Features

  • High operational efficiency of 87% to minimize thermal losses inside control cabinets.
  • Wide input voltage range supporting 85 to 264 V AC and 80 to 370 V DC.
  • Adjustable output voltage from 22 to 28 V DC via a front-panel potentiometer.
  • Tricolor LED diagnostics for real-time status indication (Green, Yellow, Red).
  • Integrated floating relay contact for remote monitoring of output status.
  • Robust, corrosion-resistant metal housing with a compact 40 mm width.
  • Support for parallel connection of up to 5 units to increase power capacity.

Applications

  • Industrial automation and control cabinet assembly.
  • Machine building and precision factory automation.
  • Process engineering and water treatment facilities.
  • Power distribution networks and wind energy systems.

Technical Specifications

Manufacturer Weidmuller
Part Number/Model 1469480000 (PRO ECO 120W 24V 5A)
Input Voltage Range (AC) 85...264 V AC (derating at 100 V AC)
Input Voltage Range (DC) 80...370 V DC (derating at 120 V DC)
Input Frequency Range 47...63 Hz
AC Current Consumption 1.26 A @ 230 V AC / 2.24 A @ 110 V AC
DC Current Consumption 0.39 A @ 370 V DC / 1.16 A @ 120 V DC
Inrush Current max. 40 A
Nominal Output Voltage 24 V DC +/- 1 %
Output Voltage Range 22...28 V DC (adjustable via potentiometer)
Continuous Output Current 5 A @ 55 degC, 3.75 A @ 70 degC
Output Power 120 W
Residual Ripple / Breaking Spikes less than 50 mVPP @ 24 V DC, IN
AC Failure Bridging Time greater than 80 ms @ 230 V AC / greater than 20 ms @ 115 V AC
Efficiency 87%
Power Loss (Idling / Nominal Load) 4 W / 15 W
Status Indication Green LED (Uout > 21.6 V DC), Yellow LED (Iout > 90% nominal), Red LED (overload, overtemperature, short-circuit, Uout < 20.4 V DC)
Floating Contact / Relay Yes (max. 30 V DC / 1 A), active when Uout > 21.6 V DC
Connection System Screw connection
Conductor Cross-Section (Rigid) 0.5...6 mm² (AWG 26...12)
Conductor Cross-Section (Flexible, Input) 0.5...2.5 mm² (max)
Operating Temperature -25 degC to 70 degC
Storage Temperature -40 degC to 85 degC
Dimensions (W x H x D) 40 mm x 125 mm x 100 mm
Net Weight 675 g

Connections and Interfaces

Connection Type Terminal Specification / Function
Input Terminals Screw connection for L, N, and PE (0.5 to 6 mm² rigid)
Output Terminals Screw connection for +24 V DC and -24 V DC
Status Relay Floating contact (NO), max. 30 V DC / 1 A for remote diagnostics

Installation Guidelines

  • Mounting: Snap vertically onto a standard TS 35 DIN rail. Ensure the internal cooling vents are positioned at the top and bottom.
  • Clearance: Maintain adequate clearance above and below the module to facilitate natural convection cooling and prevent thermal derating.
  • Wiring: Use appropriate wire cross-sections (up to 6 mm² for rigid conductors) and ensure screw terminals are tightened to the recommended torque.
  • Grounding: Connect the PE (Protective Earth) terminal securely to the system ground to ensure proper electromagnetic compatibility (EMC) and electrical safety.

What is the output voltage range of the Weidmuller 1469480000?

The nominal output voltage is 24 V DC, which can be adjusted between 22 and 28 V DC via the front-facing potentiometer.

What are the LED status indicators on the PRO ECO 120W power supply?

The unit features three LEDs: a Green LED indicating output voltage is above 21.6 V DC, a Yellow LED indicating output current exceeds 90% of the rated current, and a Red LED indicating overload, overtemperature, short-circuit, or output voltage below 20.4 V DC.

Can multiple Weidmuller PRO ECO 120W units be connected in parallel?

Yes, up to a maximum of 5 units can be connected in parallel to increase power capacity or for redundancy.

What is the operating temperature range for this power supply?

The operating temperature range is -25 degC to 70 degC, with derating applied above 55 degC (continuous output is 5 A at 55 degC, and 3.75 A at 70 degC).

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...