1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Beckhoff EL6688 EtherCAT Terminal 1-port IEEE 1588 Communication Interface

Beckhoff EL6688 EtherCAT Terminal 1-port IEEE 1588 Communication Interface

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: EL6688

  • Menşei ülke:Almanya

  • Ürün Türü: EtherCAT Terminals

  • Ödeme: T/T, Western Union

  • Ağırlık: 2000g

  • Boyutlar: 24 mm x 100 mm x 52 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Time-synchronous communication across distributed systems is executed reliably by the Beckhoff EL6688 EtherCAT Terminal, which functions as a dedicated 1-port communication interface supporting the IEEE 1588/PTP (Precision Time Protocol) standard. This compact module acts as a high-precision bridge, enabling seamless synchronization between EtherCAT networks and external Ethernet-based systems either as a grandmaster or a slave clock. Integrating the Beckhoff EL6688 into your control architecture provides the physical and protocol interface necessary to keep real-time industrial cycles aligned within sub-microsecond margins, functioning directly as a reference clock within the TwinCAT software ecosystem.

Features

  • Dual Protocol Compatibility: Fully supports both PTPv1 (IEEE 1588-2002) and PTPv2 (IEEE 1588-2008) specifications.
  • Flexible Clock Status: Configurable dynamically to operate in Master or Slave mode.
  • Robust Physical layer: Features a single 10BASE-T/100BASE-TX RJ45 Ethernet port with auto-negotiation and auto-crossing.
  • Distributed Clocks (DC): Integrated Distributed Clocks capability for microsecond-level synchronization precision.
  • Electrical Isolation: Certified galvanic isolation up to 500 V between the internal E-bus circuitry and the external Ethernet network.

Applications

  • Synchronization of geographically dispersed PLC and motion control architectures.
  • Integration of test bench monitoring equipment with microsecond-accurate timestamp requirements.
  • Substation and power generation distribution system monitoring (IEEE 1588 network synchronization).
  • Multi-axis coordinated motion control across isolated network boundaries.

Technical Specifications

Manufacturer Beckhoff Automation
Model / Article Number EL6688
Bus System EtherCAT (E-bus connection)
Ethernet Port Type 1 x RJ45 (10BASE-T/100BASE-TX)
Data Transfer Speed 10/100 Mbit/s (IEEE 802.3u Auto-Negotiation, half/full duplex)
Supported Protocol PTPv1 (IEEE 1588-2002), PTPv2 (IEEE 1588-2008)
Distributed Clocks (DC) Yes
Current Consumption (E-bus) Typical 310 mA
Electrical Isolation 500 V (E-bus to Ethernet interface)
Diagnostic Indicators Link/Activity LED, Status LEDs (Run, Error, PTP Status)
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Relative Humidity 95%, non-condensing
Housing Material Polycarbonate
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Mounting Type 35 mm DIN rail (EN 60715) with locking tab
Protection Rating IP20
Approvals CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)

Empirical Engineering Insights

Alternative Models & Compatibility

The EL6688 is uniquely optimized for PTP time synchronization. If you require standard TCP/IP Ethernet communication bypass without high-precision sub-microsecond synchronization protocols, the EL6601 or EL6614 terminals should be used instead. For bridging time systems between two completely isolated EtherCAT networks, consider pairing the EL6688 with an EL6692 or EL6695 EtherCAT bridge terminal.

Application Pitfalls & Engineering Notes

With a high E-bus current consumption of 310 mA typical, systemic integration requires a close audit of your current coupler's power budget (such as an EK1100). If multiple high-draw modules reside in the same physical slice segment, you must deploy an EL9410 power supply terminal immediately upstream to avoid bus communication instability or system resets under heavy traffic loads.

Commissioning & Wiring Tips

To ensure the maximum phase accuracy of the IEEE 1588 protocol, avoid using daisy-chained unmanaged switches between the master clock and the EL6688 RJ45 interface. Standard unmanaged switches introduce unpredictable packet jitter which degrades the accuracy of the PTP sync mechanism. Always use high-quality Cat.5e or Cat.6 shielded cables to isolate synchronization packets from high-frequency EMC field noise.

Installation Guidelines

CRITICAL WARNING

Always isolate all electrical power systems prior to installation, removal, or terminal replacement. Do not hot-swap the terminal while the bus segment is active. Failure to fully power down the bus segment can cause immediate damage to internal E-bus components or communication loss on the downstream nodes.

1

Align the terminal side-by-side with the adjacent coupler or terminal module using the guide slots on the housing.

2

Press the EL6688 firmly onto the standard 35 mm DIN rail until the locking tab engages securely with a tactile click.

3

Connect a shielded Ethernet cable to the front RJ45 port and verify the mechanical lock clicks into position.

4

Configure the TwinCAT system manager to recognize the PTP configuration parameters (master or slave role selection).

Loading product navigation…

What is the primary function of the Beckhoff EL6688 module?

The EL6688 acts as a 1-port IEEE 1588/PTP communication interface, allowing an EtherCAT network to synchronize with external Ethernet networks either as a grandmaster or a slave clock.

Does the EL6688 require an external power supply?

No, it is powered directly via the internal EtherCAT E-bus interface, consuming a typical current of 310 mA.

Which PTP protocols are supported by this EtherCAT terminal?

The module is compatible with both PTPv1 (IEEE 1588-2002) and PTPv2 (IEEE 1588-2008) protocols, which can be configured within TwinCAT.

What happens if my system exceeds the E-bus current limit with the EL6688 installed?

Exceeding E-bus limits can cause erratic communication or diagnostic faults. If your total slice power draw exceeds coupler capacity, install an EL9410 power supply terminal adjacent to the EL6688.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Sıvıların Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Uygulamalı Eğitim

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...