1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Beckhoff IP1012-B510 Fieldbus Box 8-channel Digital Input Module

Beckhoff IP1012-B510 Fieldbus Box 8-channel Digital Input Module

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: IP1012-B510

  • Menşei ülke:Almanya

  • Ürün Türü: Fieldbus Box Modules

  • Ödeme: T/T, Western Union

  • Ağırlık: 2000g

  • Boyutlar: 30 mm x 175 mm x 26.5 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Processing eight digital inputs directly in the field, the Beckhoff IP1012-B510 provides high-speed signal acquisition for CANopen networks without requiring a protective control cabinet. This distributed I/O module features a robust, fully-sealed IP67 enclosure, making it ideal for decentralized automation topologies where space is limited and environment conditions are harsh. With a rapid 0.2 ms input filter and integrated sensor power supply, the module interfaces seamlessly with proximity sensors, limit switches, and photoelectric sensors to transmit precise state changes over the CANopen industrial protocol.

Features

  • High-Speed Signal Capture: 0.2 ms digital input hardware filter prevents contact bounce and ensures deterministic state capture.
  • Decentralized CANopen Node: Integrates directly into CANopen networks with support for up to 16 send and 16 receive PDOs.
  • Hardened IP67 Housing: Fully encapsulated polyamide structure resistant to water jets, dust, and mechanical vibration.
  • Protected Sensor Power Supply: Delivers up to 0.5 A total auxiliary power to connected sensors with complete short-circuit protection.
  • Direct M12 Connection: Standardized industrial connection points minimize field wiring errors and optimize signal integrity.

Applications

  • Automotive Assembly Lines: Distributed sensor gathering on robotic arms and transfer stations.
  • Conveyor and Material Handling Systems: Direct mounting on structural profiles to track package routing and sensor states.
  • Food & Beverage Processing: Washdown-heavy environments requiring moisture-resistant remote I/O blocks.
  • Packaging Machinery: Compact field deployment to minimize cabinet size and reduce routing costs.

Technical Specifications

Parameter Value
Manufacturer Beckhoff Automation
Model Number IP1012-B510
Fieldbus Protocol CANopen (automatic detection from 10 kbaud to 1 Mbaud)
Number of Inputs 8 digital inputs (type 2 according to EN 61131-2)
Input Connections M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 0.2 ms
"0" Signal Voltage -3 V to +5 V
"1" Signal Voltage 11 V to 30 V
Input Current Typically 6 mA
Sensor Supply Max. 0.5 A total, short-circuit proof
Bus Interface 1 x M12 plug, 5-pin
Electrical Isolation Control voltage / fieldbus: 500 V
Current Consumption (Us) 45 mA + sensor load (max. 0.5 A)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65/66/67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Housing Material PA6 (Polyamide)
Shipping Weight (Calculated) 2.0 Kg (including heavy industrial packaging)

Connections and Interfaces

Interface Type Pin / Terminal Assignment Function / Circuit Assignment
CANopen Bus (M12 Male, 5-pin) Pin 1 Shield / Functional Earth
Pin 2 V+ (Bus supply voltage)
Pin 3 V- (Bus reference potential)
Pin 4 CAN_H (Data High)
Pin 5 CAN_L (Data Low)
Power Supply Feed (M8 Male, 4-pin) Pin 1 +24 V DC control voltage (Us)
Pin 2 +24 V DC auxiliary load voltage (Up)
Pin 3 GND (Us)
Pin 4 GND (Up)
Digital Inputs (M12 Sockets 1-4) Pin 1 +24 V DC sensor supply (derived from Us)
Pin 2 Digital Input Channel B (Even numbers: 2, 4, 6, 8)
Pin 3 GND (Us)
Pin 4 Digital Input Channel A (Odd numbers: 1, 3, 5, 7)
Pin 5 Functional Earth (FE)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP1012-B510 utilizes standard CANopen architecture. If compatibility requirements demand an alternate physical footprint, the IP1002-B510 utilizes the same technical structure but implements 8 x M8 connections instead of the M12 format. For migration from older physical nodes, verify that your CANopen network master (such as Beckhoff FC5101 or EL6751) is configured to parse the 8-bit process image. If replacing a PROFIBUS node (IP1012-B310) with this model, the complete trunk-line cabling must be updated to conform to CAN physical layer standards.

Application Pitfalls & Engineering Notes

A common point of field failure is the total sensor supply limit. The module provides a maximum of 0.5 A across all 8 channels. When using active proximity sensors, calculate the total current draw. If high-draw photoelectric sensors exceed 500 mA combined, the internal self-resetting fuse will trip, cutting sensor power. If thermal degradation occurs due to direct sunlight or ambient temperature nearing +55 degC, the internal resistance of the fuse increases, lowering this trip threshold. Use an auxiliary power distributor if high-load sensors are required.

Commissioning & Wiring Tips

Baud rate and Node ID settings are configured via rotary address switches located underneath the protective transparent screw-cap. Ensure these rotary switches are set before powering the network. Always replace and tighten the protective cap with its integrated rubber gasket to maintain the IP67 moisture and dust seal. When installing long bus segments, verify that a 120-Ohm CAN termination resistor is applied to the final physical node on the network to prevent signal reflections and packet drops.

Installation Guidelines

CRITICAL WARNING

Isolate all control and auxiliary power networks before performing any physical installation or maintenance. Hot-plugging industrial sensors or bus lines under load can cause voltage spikes, damaging the internal optical isolation circuitry of the CANopen communications block.

1

Mount the Fieldbus Box to a flat, vibration-free surface using the two 3.5 mm integrated mounting holes. Secure with M3 bolts to a maximum tightening torque of 0.8 Nm.

2

Verify that the CANopen network speed matches your PLC configuration before adjusting the node address rotary switches. Securely tighten the protective faceplate cap afterward.

3

Connect the incoming 24 V DC power using the 4-pin M8 male connector. If daisy-chaining multiple modules, utilize the downstream female M8 connector, ensuring the aggregate current does not exceed the limit of the primary supply line.

4

Attach M12 sensor cables. Seal any unused M12 and M8 ports with protective plastic screw-plugs to retain the system's IP67 ingress rating.

What is the maximum sensor current capacity of the Beckhoff IP1012-B510?

The module provides a maximum of 0.5 A total sensor supply current across all eight digital input channels. This supply is short-circuit protected.

Does the IP1012-B510 support communication speed auto-detection?

Yes, it supports automatic detection of CANopen baud rates ranging from 10 kbaud up to 1 Mbaud, aligning with host master settings.

How are the Node ID and communication settings configured?

They are configured via mechanical rotary address switches located underneath the protective clear screw-on cap on the front of the module.

What is the difference between the IP1012-B510 and the IP1002-B510?

Both modules share the same electrical and CANopen specifications; however, the IP1012-B510 uses M12 connectors, while the IP1002-B510 utilizes smaller M8 connectors.

Does the IP1012-B510 require an IP-rated enclosure?

No. Due to its fully-sealed polyamide PA6 housing conforming to IP65, IP66, and IP67 protection standards, it can be mounted directly on the machine frame in harsh, wet, or dusty environments.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...