1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Beckhoff IP2020-B200 Fieldbus Box

Beckhoff IP2020-B200 Fieldbus Box

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: IP2020-B200

  • Menşei ülke:Almanya

  • Ürün Türü: Fieldbus Box Modules

  • Ödeme: T/T, Western Union

  • Ağırlık: 500g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Designed for noise-immune distributed industrial automation, the Beckhoff IP2020-B200 establishes robust control node links through a high-speed optical fiber interface. Operating as a decentralized Fieldbus Box, this module integrates seamlessly into Lightbus ring topologies to offer rapid data transmission speeds of 2.5 Mbaud over optical fiber lines. Its design provides native galvanic isolation and absolute immunity to electromagnetic interference (EMI), making it optimal for heavy-duty manufacturing zones. The module utilizes standardized M8 connection interfaces for control power routing and features specialized fiber-optic sockets configured for direct-plug compatibility.

Features

  • High-Speed Lightbus Interface: Operates at a constant 2.5 Mbaud rate for deterministic control cycles.
  • Immunity to Electrical Noise: Utilizes dual fiber-optic connections for total electrical isolation between control logic and the field network.
  • Configurable Field Parameters: Supports full configuration through Beckhoff KS2000 commissioning software or directly via the master PLC program.
  • Flexible Auxiliary Power Routing: Separate control voltage and load voltage circuits mapped across dedicated 4-pin M8 sockets.
  • Robust Environmental Protection: Sealed IP67-rated housing supports cabinet-free installation directly on machinery.

Applications

  • Automotive Assembly Lines: High-EMI welding environments requiring secure, non-conductive data transfer.
  • Packaging and Material Handling: Distributed topologies with high mechanical vibration and long cable runs.
  • Hazardous/Corrosive Areas: Applications where optical isolation prevents ground loops and spark hazards.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Designation IP2020-B200
Bus Interface 2 x fiber-optic socket for plug ZS1020-0010
Data Transfer Rate 2.5 Mbaud
Control Supply Voltage 24 V DC (-15% / +20%)
Power Feed Connector 1 x M8 male socket, 4-pin
Downstream Power Connector 1 x M8 female socket, 4-pin
Electrical Isolation Control voltage to fieldbus: Yes
Operating Temperature 0 degC to 55 degC
Storage Temperature -25 degC to 85 degC
Ingress Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
Standards & Approvals CE, UL
Net Weight Approx. 250 g
Shipping Weight (Calculated) 0.55 kg (including packaging material)

Connections and Interfaces

M8 Terminal Pin Circuit Assignment Functional Description
Pin 1 +24 V DC Us Control supply voltage for internal electronics
Pin 2 +24 V DC Up Auxiliary/load supply voltage for sensors/actuators
Pin 3 GND Us Reference ground for control electronics
Pin 4 GND Up Reference ground for sensor/actuator power circuits

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2020-B200 relies on the standard Beckhoff Lightbus protocol (II2001 or FC2001 PCI cards). If migrating to EtherCAT-based infrastructure, consider transitioning to the EP-series Fieldbus Boxes (e.g., EP1111 or EP2028-0002). For maintenance of older optical rings, keep spare ZS1020-0010 plastic optical fiber plugs on hand, as connection alignment is critical to maintaining signal budget across consecutive nodes.

Application Pitfalls & Engineering Notes

Plastic optical fibers (POF) must be cut perfectly perpendicular using a dedicated optical fiber cutter (such as Beckhoff ZS1023-0003). Ragged or angled cuts lead to high optical attenuation, triggering intermitted packet drops and system fault codes on the master controller. Maintain a minimum bend radius of 25 mm for the optical fiber to avoid permanent stress damage to the physical core.

Commissioning & Wiring Tips

When configuring node addresses via KS2000, ensure your PC-to-node interface baud rate is set to match the hardware default. When checking the optical power level budget, use the diagnostic register status flags inside the PLC control word to verify the optical link quality before putting the system into high-demand operation.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary power systems (Us and Up) before inserting or removing the M8 connectors or optical fiber connections. Failure to do so can cause voltage spikes on signal pins or physical contamination of open optical sockets, resulting in permanent optical link degradation.
1

Mount the IP2020-B200 securely to a flat, rigid panel surface or machine frame using M4 industrial mounting bolts. Do not apply mechanical tension to the housing.

2

Insert the fiber-optic plugs (ZS1020-0010) into the dedicated optical ports. Ensure they seat firmly and the retention sleeve clicks or secures tightly.

3

Connect the 4-pin M8 auxiliary power cables to the male input port. Torque the M8 threaded connector ring to 0.4 Nm to guarantee the IP67 moisture seal.

4

If running downstream modules, extend power out of the female M8 port using industrial shielded cabling. Seal any unused ports with protective IP67 plastic caps.

Loading product navigation…

What is the primary function of the Beckhoff IP2020-B200?

It acts as a distributed Fieldbus Box node that interfaces field signals with a Lightbus master system via a high-speed fiber-optic connection running at 2.5 Mbaud.

What connectors are used for power transmission on this module?

It features a 4-pin M8 male socket for power feed-in and a 4-pin M8 female socket for daisy-chaining auxiliary and control voltages to downstream modules.

Does the IP2020-B200 require a special optical plug?

Yes, it uses the ZS1020-0010 plastic optical fiber plug specifically configured for Beckhoff Lightbus communication ports.

How do you configure the parameters of this Fieldbus Box?

Configuration parameters can be modified through the Beckhoff KS2000 software suite or mapped through software register commands directly via the controller.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...