Beckhoff KS6771 Bus Terminal MP-Bus Master Module

Beckhoff KS6771 Bus Terminal MP-Bus Master Module

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: KS6771

  • Menşei ülke:Almanya

  • Ürün Türü: Bus Terminals

  • Ödeme: T/T, Western Union

  • Ağırlık: 1500g

  • Boyutlar: 12 mm x 100 mm x 68 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Actuating as a dedicated integration link, the Beckhoff KS6771 Bus Terminal enables direct, bidirectional communication between a K-bus coupler and Belimo MP-Bus HVAC field devices. This module functions as an MP-Bus master, coordinating data acquisition and control command distribution over a single channel. The KS6771 design features a pluggable wiring level, allowing swift module swaps without disconnecting field-level wiring harnesses. Integration is fully managed via standard TwinCAT PLC function blocks, streamlining commissioning across complex commercial and industrial air handling architectures.

Features

  • Multi-Device Topologies: Controls up to 16 MP-Bus devices (maximum 8 drives and 8 sensors) over a single fieldbus drop.
  • Pluggable Wiring Interface: Uses tension-clamp connection terminals that can be detached as a single block for expedited terminal replacement.
  • Galvanic Isolation: Provides robust 500 V isolation between the internal K-bus and the external MP-Bus circuitry to suppress common-mode electrical noise.
  • Efficient Process Image: Maps directly into the controller configuration utilizing 12 bytes of input data and 12 bytes of output data.
  • Standardized Diagnostics: Fully compatible with the TwinCAT PLC MP-Bus software library for fast system integration and continuous error reporting.

Applications

  • HVAC Variable Air Volume (VAV) Systems: Direct control of volumetric flow controllers, damper actuators, and temperature sensors.
  • Industrial Environmental Controls: Closed-loop control of pressure relief valves and air-handling units within cleanrooms or pharmaceutical laboratories.
  • Building Management Systems (BMS): Integration of distributed Belimo valve actuators and auxiliary sensors into high-level Ethernet/IP or EtherCAT backbones.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model Number KS6771
Interface Type MP-Bus Master (1 Channel)
Data Transfer Rate 1200 baud
Bus Access Protocol Polling
Nominal System Voltage 24 V DC (-15% / +20%)
K-Bus Current Consumption Typically 55 mA
Power Contact Consumption Typically 10 mA + actuator load
Maximum Power Contact Load 10 A
Isolation Voltage 500 V (K-bus to MP-Bus line)
Process Image Width 12 bytes input, 12 bytes output
Connection Cross-Section 0.08 to 1.5 mm² (AWG 28...16 solid/stranded; AWG 26...16 flexible)
Wire Stripping Length 9 to 10 mm
Environmental Rating IP20 (with variable installation orientation)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95% non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Explosion Protection Marking II 3 G Ex nA IIC T4 Gc (ATEX Zone 2)
Housing Material Polycarbonate (terminal housing with pluggable wiring)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Product Net Weight Approximately 85 g
Shipping Weight (Calculated) 1.5 kg

Connections and Interfaces

Terminal Pin Number Signal Assignment Description
1 MP-Bus Line Bidirectional communications line to Belimo slave actuators.
2 24 V DC (Power Contact) Power feed to drive units (internally bridged to power contact).
5 GND (MP-Bus Reference) Common reference potential for MP-Bus communication.
6 0 V DC (Power Contact) Negative power rail reference (internally bridged to power contact).

Empirical Engineering Insights

Alternative Models & Compatibility

The KS6771 is direct operational equivalent to the standard KL6771 Bus Terminal. The critical difference lies in the "KS" terminal housing design, which includes a pluggable wiring block. From a software perspective, the TwinCAT hardware configuration treats the KS6771 identically to the KL6771, enabling seamless drop-in replacements in existing PLC programs without necessitating code modifications or IO mapping updates.

Application Pitfalls & Engineering Notes

When deploying the KS6771, engineers must monitor total current consumption on the external 24 V DC supply loop. The terminal relies on internal power contacts rated for a maximum of 10 A. If several heavy damper drives are powered directly through the bus terminal, ensure the combined peak inrush currents do not exceed this threshold. For installations spanning long physical distances, use shielded twisted-pair cables to mitigate inductive noise coupling, which can disrupt the 1200-baud polling cycles.

Commissioning & Wiring Tips

To configure the bus terminal within the TwinCAT environment, the Tc2_MPBus library must be integrated into the PLC project. When addressing Belimo devices, remember that the MP-Bus allows 8 active control drives and 8 passive sensors. When inserting stranded field conductors, use the pluggable tension-clamp release slot with a standard flat-head screwdriver (3.0 mm blade size) to avoid damaging the polycarbonate terminal guide locks.

Installation Guidelines

CRITICAL WARNING: Prior to installing, removing, or wiring the KS6771 terminal, completely de-energize the main system controller and all auxiliary 24 V power feeds. Failure to isolate power may cause communication bus disruption or permanent damage to the solid-state K-bus interface electronics.
1
Mount the terminal on a standard 35 mm DIN rail conforming to EN 60715, ensuring the lock mechanism snaps firmly into place.
2
Slide adjacent terminals together, using the integrated double slot and key connection for side-by-side electrical contact.
3
Prepare field wires by stripping insulation precisely to 9–10 mm, avoiding loose strands that could cross-contact neighboring terminals.
4
Insert field wiring into the pluggable tension clamps, using a spring-release screwdriver tool to lock each wire securely into position.
Loading product navigation…

What is the primary difference between the Beckhoff KS6771 and KL6771 terminals?

The KS6771 features a pluggable wiring level, enabling the field wiring block to be removed and plugged back on as a single assembly. The KL6771 uses fixed, non-removable terminal block connections.

How many Belimo actuator drives can I connect to a single KS6771 module?

The terminal supports a maximum of 16 MP-Bus devices, which is architecturally split into up to 8 drives and 8 sensors.

What software library is required to program this terminal in TwinCAT?

Integration requires the TwinCAT PLC MP-Bus library (typically Tc2_MPBus for TwinCAT 3), which provides dedicated function blocks for communication and device polling.

Is the KS6771 rated for use in hazardous locations?

Yes, it has ATEX approval with marking II 3 G Ex nA IIC T4 Gc, making it suitable for installation in Zone 2 hazardous areas.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...