1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Omron G3PE-235B-2N G3PE Series 3-Phase Solid State Relay

Omron G3PE-235B-2N G3PE Series 3-Phase Solid State Relay

Stokta sadece 8 adet kaldı
  • Üretici: Omron

  • Ürün No.: G3PE-235B-2N

  • Menşei ülke:Japonya

  • Ürün Türü: Solid State Relays

  • Ödeme: T/T, Western Union

  • Ağırlık: 500g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Engineered for precise industrial thermal regulation, the Omron G3PE-235B-2N facilitates highly efficient switching of three-phase heating loads up to 35 A. Utilizing a 2-phase switching topology, this device simplifies wiring in three-phase delta or star configurations without a neutral wire, providing a compact footprint inside electrical control panels. The integrated zero-cross function minimizes electromagnetic interference and electrical noise generation, safeguarding surrounding analog automation instrumentation during high-frequency cycling.

Features

  • Two-Phase Switching: Economical 2-element control configuration designed specifically for balanced 3-phase loads.
  • Zero Cross Function: Suppresses initial inrush currents and harmonic distortion by turning ON only when the AC voltage waveform crosses zero.
  • Phototriac Isolation: High-dielectric isolation barriers between low-voltage input control circuits and the power distribution grid.
  • Robust Overload Tolerance: High surge resistance rating designed to withstand short-duration high-current transients.

Applications

  • Plastic extrusion and blow molding machine barrel heating.
  • Semiconductor manufacturing chamber temperature maintenance.
  • Industrial ovens, furnaces, and drying tunnels.
  • Packaging heat-sealing bars and shrink wrap tunnel elements.

Technical Specifications

Parameter Value
Manufacturer Omron
Model Code G3PE-235B-2N
Rated Input Control Voltage 12 to 24 VDC
Operating Input Voltage Range 9.6 to 30 VDC
Input Current 10 mA maximum (at 24 VDC)
Rated Load Voltage 100 to 240 VAC
Load Voltage Range 75 to 264 VAC
Continuous Load Current 35 A (at an ambient temperature of 40 degC)
Minimum Load Current 0.5 A
Inrush Current Resistivity 440 A (60 Hz, 1 cycle)
Permissible I2t Value 1260 A2s
Load Capacity 12.1 kW (at 200 VAC)
Isolation Method Phototriac
Terminal Type Screw terminals (with integrated terminal cover)
Mounting Style DIN-rail and panel surface mounting
Shipping Weight (Calculated) 3.0 kg

Connections and Interfaces

Terminal Designation Function / Circuit Assignment
A1 / A2 (Input) Control DC voltage input (positive/negative terminals)
L1 / T1 (Output) Phase 1 AC power line input and load connection (Switched)
L2 / T2 (Output) Phase 2 AC power line input and load connection (Switched)
L3 / T3 (Output) Phase 3 direct bypass connection (Not switched internally, used for 2-phase control conduction path)

Empirical Engineering Insights

Alternative Models & Compatibility

The "2N" designation specifies a 2-element (2-phase switching) module. If your application relies on a 3-element switching topology (e.g., systems containing grounded neutral star connections that require isolation on all lines), you must utilize the "3N" series variant instead. The physical mounting footprint and input terminal configurations remain identical between the two series, facilitating an easy mechanical upgrade path.

Application Pitfalls & Engineering Notes

Thermal management is the most critical factor for reliable SSR operation. When operating continuously at 35 A, the module must have unrestricted vertical convection airflow. If mounting multiple G3PE controllers side-by-side within an unventilated control panel, apply a derating factor of 10% to 20% to prevent thermal runaway. Ensure the heat sink fins remain clear of dust build-up.

Commissioning & Wiring Tips

Always use ring crimp terminals matching the screw terminal specs to ensure robust surface contact under thermal cycling. Under-tightened screw terminals will generate localized resistance-induced heat, leading to terminal housing degradation. To prevent damage from short-circuits on the load side, install fast-acting semiconductor fuses upstream of the SSR, sized to blow well below the internal 1260 A2s limit.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

De-energize all primary load supply lines and auxiliary DC control supplies before undertaking installation, terminal adjustments, or inspection. Treat all heat sink structures as potentially hot during and directly following operation.

1

Mount the module vertically to a standard 35mm DIN rail or directly to a flat metal backplate using the mounting screws to optimize heat sink chimney-effect convection.

2

Ensure a minimum of 80mm free clearance directly above and below the device to allow proper airflow dissipation.

3

Apply the correct DC input control polarity (12 to 24 VDC) to terminals A1 (+) and A2 (-). Check polarity before energizing control circuits.

4

Secure load wiring to the output terminal blocks, ensuring torque meets Omron standard specifications for M4/M5 terminal screws to avoid high-contact-resistance hotspots.

Loading product navigation…

What is the key functional difference between G3PE-235B-2N and the 3N variant?

The -2N suffix designates a 2-element (2-phase switching) SSR that switches power on two of the three phases, allowing the third phase to bypass directly. The -3N variant switches all three phases. 2N models are ideal and highly cost-effective for balanced delta and star three-phase configurations without a neutral line.

How does the zero-cross function benefit heating control systems?

The zero-cross function switches the SSR ON only when the AC load voltage is close to 0V. This significantly reduces high-frequency noise spikes, protecting adjacent sensitive control modules, communication buses, and PLC analog inputs from electromagnetic interference.

What short-circuit protection is recommended for the G3PE-235B-2N?

To protect the internal thyristors from irreversible overcurrent damage, you must install an ultra-fast semiconductor fuse on the supply lines. The fuse must have an I2t clearing rating lower than the module's limit of 1260 A2s.

Do I need to apply thermal grease to this module during installation?

No. The G3PE-235B-2N comes pre-equipped with an integrated high-efficiency heatsink specifically matched to the thermal profile of its internal components, eliminating the need to mount the SSR block to an external heat transfer surface.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Japonya

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...