1 of 1

Beckhoff C9900-E701 CP6xxx CP7xxx Series Push-Button Extension

Beckhoff C9900-E701 CP6xxx CP7xxx Series Push-Button Extension

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: C9900-E701

  • Country of origin:Germany

  • Product Type: Control Panel Push-Button Extensions

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 450 x 200 x 150 mm (17.7 x 7.9 x 5.9 in)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for seamless physical integration alongside 15-inch control interfaces, the Beckhoff C9900-E701 provides supplementary tactile control elements for the CP6xxx and CP7xxx Control Panel and Panel PC series. This right-side mounted extension module bridges physical push-button operations with digital control bus networks, offering operators immediate, tactile feedback without utilizing screen real estate. Outfitted with heavy-duty Siemens Signum square 30 x 30 mm push-buttons and an independent Emergency Stop circuit, this assembly supports hybrid wiring structures to balance high-speed bus communication with fail-safe, hardware-interlocked emergency circuits.

Features

  • Optimized Compatibility: Purpose-built for mounting on the right-hand side of Beckhoff CP6x21-00xx and CP7x21-00xx 15-inch displays without integrated keyboards.
  • High-Tactile Interface: Equipped with 12 square 30 x 30 mm Siemens Signum push-button keys, complete with individual signal lamps.
  • Dual-Channel Safety Design: Incorporates 1 Siemens Signum emergency stop key designed for direct, hardwired safety loop integration.
  • Flexible Signal Routing: Primary normally-open (NO) contacts for all buttons route directly via CP-Link or USB, while a secondary terminal row provides direct-wiring paths for redundant, independent physical interlocking.
  • In-Field Customization: Insertable label plates beneath transparent push-button caps allow quick, application-specific functional labeling.

Applications

  • Heavy Industrial Machinery: Direct physical jog, homing, and cycle-start overrides adjacent to main visualization software.
  • Automotive Assembly Lines: Standardized operator consoles requiring dedicated hardware-interlocked E-stop functionality.
  • Process Plant Visualization: Panel-mount operator stations where software-only button actions pose potential operational delay risks.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff Automation
Model Designation C9900-E701
Compatible Panels CP6x21-00xx & CP7x21-00xx series (15-inch displays without keyboard)
Mounting Configuration Right-side mounting relative to display face
Operator Elements 12 x push-buttons (Siemens Signum, 30 x 30 mm) with integrated signal lamps
Primary Contact Path Secondary Contact Path 2nd Normally Open (NO) contact wired directly to physical terminal block row
Signal Lamp Control Transmitted exclusively via CP-Link or USB interface
Emergency Stop Element 1 x Siemens Signum twist-to-release E-stop button (directly wireable)
Shipping Weight 5.0 kg (11.0 lbs)
Package Dimensions (Calculated) 450 x 200 x 150 mm (17.7 x 7.9 x 5.9 in)

Connections and Interfaces

Interface Type Connection Route & Signal Behavior
CP-Link / USB Bus Connection Transmits State 1 NO contact from each of the 12 buttons. Provides execution signals directly to the individual button feedback LEDs.
Direct Terminal Row Bypasses the communication controller, permitting dedicated copper wire connections for State 2 NO contacts. Useful for hardwired hardware safety feedback.
E-Stop Terminals Dedicated direct-wire connection blocks on the rear panel. Complete physical segregation from the digital CP-Link or USB communication logic.

Empirical Engineering Insights

Alternative Models & Compatibility

The C9900-E701 is designed specifically for Beckhoff 15-inch display form factors without built-in keyboards. Integrating this extension with a model containing a physical keyboard is not mechanically possible due to spatial structural interference. When swapping panels during machine service phases, ensure that the communication bus setup (CP-Link versus direct USB) matches the control unit's existing interface cards, as logic mapping on the host Industrial PC will change accordingly.

Application Pitfalls & Engineering Notes

A common issue in field installations is routing safety-critical Emergency Stop signals through the USB or CP-Link bus rather than hardwiring them. Software-driven button monitoring is not rated for functional safety (SIL/PL) compliance. The red Emergency Stop mushroom cap must be direct-wired using copper connections through the dedicated rear terminal row to a certified safety controller or safety monitoring relay.

Commissioning & Wiring Tips

To protect the serial signaling over CP-Link/USB from electromagnetic interference, ensure that the connection cable running from the control panel to the main cabinet is fully shielded and routed separately from high-voltage motor cables or variable frequency drive (VFD) lines. In high-vibration environments, use strain reliefs at the direct terminal block row to prevent lead fatigue on the auxiliary NO contacts.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical supply voltages to the Control Panel and terminal row circuits before starting mechanical mounting. Verify that all safety circuits are completely de-energized. Hardwired Emergency Stop lines must be validated for loop resistance and correct physical logic execution before restoring system operation.

1 Align the extension housing with the pre-drilled right-side mounting points on the 15-inch Control Panel.
2 Secure the mechanical connection bolts using standard industrial torque parameters to maintain structural integrity.
3 Plug the CP-Link or USB communication cable directly into the designated rear interface port.
4 Wire the secondary physical NO contacts and E-Stop loops to the integrated screw-clamp terminal row.
5 Restore control power, configure the button mapping in the controller software, and execute functional verification of the Emergency Stop loop.

Can the emergency stop button on the C9900-E701 be monitored solely via USB or CP-Link?

No. To meet industrial functional safety requirements, the Siemens Signum Emergency Stop button must be hardwired directly into a safety relay or physical safety controller using its independent, direct rear-panel terminal blocks.

What is the physical size of the individual push-buttons on this extension?

The module contains 12 square Siemens Signum push-buttons, each measuring 30 x 30 mm, integrated with internal signal lamps.

How are the signaling lamps controlled on the C9900-E701?

The feedback lamps inside the push-buttons are controlled and powered exclusively through the USB or CP-Link communication interface; they cannot be hardwired via the terminal blocks.

Is it possible to mount the C9900-E701 on the left side of a control panel?

No, this specific model is mechanically designed and oriented strictly for right-side mounting relative to the display face on compatible 15-inch Beckhoff control units.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...