Description

The Emerson PR6426/010-030 non-contact sensor combined with the CON021/916-160 signal converter forms an advanced eddy current measurement system designed for critical turbomachinery applications, such as steam, gas, and hydro turbines, compressors, pumps, and fans. The PR6426 eddy current sensor specializes in measuring radial and axial shaft displacement, position, eccentricity, and motion under demanding industrial environments. The processed information is transferred via the CON021/916-160 converter to provide a stable electrical output for machine protection and TSI monitoring systems.

Features

  • Non-contact eddy current measurement principle for precise tracking of industrial machine conditions 
  • High-temperature durability with sensor head operation up to 175 degC 
  • Built-in protection resisting pressures up to 6,500 hpa at the sensor head 
  • Extended measurement range capacity up to 16.0mm optimized for large displacement detection 
  • Rugged design with a standard stainless steel sleeve and high-end PTFE insulation 

Applications

  • Radial and axial shaft displacement monitoring 
  • Turbomachinery position, motion, and eccentricity verification 
  • Critical machinery protection systems for gas/steam turbines and heavy compressors 

Ordering Information

Model Number Sensor Type Measuring Range Linearity Error
PR6426/010-030 32mm Eddy Current Sensor +/-4.0 mm (Standard Range) / 16.0mm Extended <= 1.5% max (Sensor) 
CON021/916-160 PR6426 16.0mm (Extended Range) <= 2.0% 

Technical Specifications

CON021/916-160 Signal Converter Specifications

Parameter Specification
Manufacturer Emerson 
Frequency Range (-3 dB) 0 to 20000 Hz 
Rise Time <15 us 
Operating Temperature Range -30 to 100 degC (-22 to 212 Fahrenheit) 
Shock and Vibration 5g @ 60 Hz @ 25 degC (77 Fahrenheit) 
Protection Class IP20 
Supply Voltage Range (-24V config) -23V to -32V (Output Range: -4V to -20V) 
Supply Voltage Range (-2V config) -21V to -32V (Output Range: -2V to -18V) 
Housing Material LMgSi 0.5 F22 
Weight ~120 grams (4.24 oz) 
Mounting Hardware 4 Screws M5x20 

PR6426 Eddy Current Sensor Specifications

Parameter Specification
Tip Diameter 32mm 
Sensitivity 2 V/mm (50.8 mV/mil) <= +/-1.5% max 
Air Gap (Center) Approx. 5.5 mm (0.22") Nominal 
Long Term Drift <0.3% 
Target/Surface Material Ferromagnetic Steel (42 Cr Mo 4 Standard) 
Maximum Surface Speed 2,500 m/s (98,425 ips) 
Minimum Shaft Diameter 200 mm (7.87") 
Operating Temperature Range -35 to 175 degC (-31 to 347 Fahrenheit) 
Temperature Excursions (<4 Hours) 200 degC (392 Fahrenheit) 
Maximum Cable Temperature 200 degC (392 Fahrenheit) 
Pressure Resistance to Sensor Head 6,500 hpa (94 psi) 
Shock and Vibration 5g (49.05 m/s2) @ 60Hz @ 25 degC (77 Fahrenheit) 
Sleeve Material Stainless Steel 
Cable Material PTFE 
Weight (Sensor & 1M Cable, no Armor) ~800 grams (28.22 oz) 

Connections/Interfaces

Connector Pin / Terminal Function
Transducer Connection Self-Locking Lemo-Plug 
Supply/Output Connection Screw Terminal Type (max. 1.5mm2 wire) 

Installation Guidelines

  • Observe the minimum cable bending radius rules: 35 mm for armored configurations and 25 mm for non-armored cables.
  • Keep a clear zone of at least 80 mm diameter around the sensor head free of unintended ferrous materials.
  • Set the center air gap to approximately 5.5 mm nominal during initial probe gap adjustment.
  • Ensure proper grounding and use external current limiting, such as safety barriers, when installing in certified hazardous areas.

Compliance and Certifications

  • CE: 2014/30/EU (EN 61326-1), 2014/34/EU, 2011/65/EU, DIN EN 50581 
  • ATEX: EN 60079-0, EN 60079-11 (II 2 G Ex ia IIC T4 Gb, -20 degC <= Ta <= 80 degC) 
  • IEC-Ex: IEC 60079-0, IEC 60079-11, IEC 60079-26 (Ex ia IIC T4 Gb, -20 degC <= Ta <= 80 degC) 
  • CSA: CAN/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04 (Class I Division 1, Groups A, B, C, D, T4; Class I Division 2, Groups A, B, C, D Ex nA II T3..T4) 
  • Standards: ANSI/UL Standard 913-2004, ANSI/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1 

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson PR6426/010-030 CON021/916-160 Eddy Current Sensor System

What is the certified measurement range for this specific configuration?

This system matches the device with an extended range converter, providing a linear measurement range of 16.0mm.

What are the temperature classifications for the sensor component?

Depending on the final area classification and paired converter, the sensor temperature limits are rated up to T6 for temperatures less than or equal to 64 degC, T4 up to 114 degC, and T3 up to 160 degC.

What material is used for the sensor sleeve and internal cable insulation?

The device features a high-grade stainless steel sleeve construction coupled with heavy-duty PTFE cable insulation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...