1 of 3

GE Multilin UR-9GH UR Series CPU Module

GE Multilin UR-9GH UR Series CPU Module

Only 5 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-9GH

  • Country of origin:United States

  • Product Type: CPU Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 177.0 mm x 482.6 mm x 234.0 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The GE Multilin UR-9GH centrally processes protection logic, communication tasks, and system diagnostics as a core processing hub within the Universal Relay (UR) platform. Specifically engineered as a replacement component for vertical hardware configurations, this CPU Module delivers coordinated calculation capacity to manage extensive electrical substation protection automation. The UR-9GH integrates dedicated serial and network communication cards to route plant parameters via industrial fieldbuses, incorporating a 9G communication architecture that establishes simultaneous links over optical networks and legacy multidrop copper lines. Additionally, it features an integrated 1A / 5A ground current transformer secondary input channel (1A/5A Ground CT) directly on the processing unit assembly. This specialized analog input enables the module to acquire local neutral or residual currents for critical zero-sequence overcurrent protection calculations, optimizing control response and field data routing across high-voltage and medium-voltage power distribution assets.

Features

  • Coordinates centralized mathematical calculation routines and real-time protection algorithms within UR-series chassis.
  • Integrates a hardware-level 1 A / 5 A ground current transformer interface directly into the controller assembly.
  • Equipped with a 9G communication configuration featuring independent dual-media network transceivers.
  • Runs standard Modbus TCP/IP and DNP 3.0 automation protocols simultaneously for SCADA and DCS master interfaces.
  • Supports high-speed oscillography capture, detailed sequence-of-events logging, and precision metering.
  • Designed specifically to match vertical mechanical orientation relay units for drop-in component replacement.

Applications

  • Substation automation and supervisory control data acquisition (SCADA) systems.
  • Electrical fault diagnostics, localized ground fault monitoring, and zero-sequence current tracking.
  • Power generation utility networks requiring concurrent dual-protocol Ethernet and serial communications.
  • Retrofit or maintenance replacement within existing UR series vertical protection systems.

Ordering Information

Code / Suffix Selection Component Description
UR-9GH Main Replacement Part Number for Vertical Units
UR UR Series Platform Designation
9G CPU Communication Type: RS485 and 10Base-F Interface Card
H CT Input Option: 1A / 5A Ground Current Transformer

Technical Specifications

Parameter Category Specification Details
Manufacturer GE Multilin (General Electric)
Country of Origin Canada
Module Type Central Processing Unit (CPU) Module
Orientation Vertical mounting configurations
Communication Profile Type 9G Architecture
COM1 Media Ports 10Base-F (Fiber) and 10Base-T (Copper Ethernet)
COM2 Media Port RS485 (Serial)
Embedded Protocols Modbus TCP/IP, DNP 3.0
Analog Ground Input Dual-rated 1 A / 5 A secondary current transformer
Dimensions Standard full-height UR Series plug-in card profile

Connections/Interfaces

Connection Port Function / Protocol Support
COM1 (10Base-F) Fiber optic network port running Modbus TCP/IP or DNP 3.0 over Ethernet.
COM1 (10Base-T) Twisted-pair RJ45 copper network port for local engineering workstation deployment.
COM2 (RS485) Balanced differential multi-drop serial terminal for legacy RTU communication.
Ground CT Terminals Rear screw terminals allocated for direct connection to external 1A or 5A secondary ground CT wiring loops.

Installation Guidelines

  • Control Power Safety: Completely isolate and disconnect the control power source feeding the UR rack before extracting or executing an upgrade with the CPU card.
  • Orientation Verification: Confirm the replacement unit matches the mechanical framework of the rack; this module is intended exclusively for vertical assembly housings.
  • ESD Mitigation: Technicians must connect an anti-static wrist strap to a verified system ground point before handling the circuit boards of the controller.
  • Firmware Configuration: After seating the module, check that the existing relay setting files and firmware revision profiles align with the new 9G configuration to avoid processing
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin UR-9GH UR Series CPU Module

What protocols are natively processed through the COM1 interface on this module?

The COM1 interface utilizes the 9G hardware configuration to handle Modbus TCP/IP and DNP 3.0 communications simultaneously across both fiber and copper links.

Can this specific CPU card be used as a direct replacement in horizontal UR chassis configurations?

No. This module is indexed and structured specifically under order codes intended for vertical replacement units and vertical hardware frames.

Does the ground current transformer input require separate software scaling for 1A and 5A operation?

Yes. The hardware loop accepts both 1 A and 5 A secondary configurations, but the input rating must be explicitly designated in the relay configuration software parameters.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered

Recently Viewed Products

Technical knowledge

OpenVMS Alpha da ishlayotgan Bailey INFI 90 Symphony HMI larini zamonaviylashtirish

OpenVMS Alpha asosida ishlayotgan eskirgan Bailey Symphony operator stantsiyalarini almashtirish bo‘yicha amaliy qo‘llanma. Unda Alpha emulyatsiyasi, OpenVMS x86 ga ko‘chirish, OPC platformasini...

Nima uchun texnik xizmat ko‘rsatish ma’lumotlari sanoat ishonchliligi uchun muhimdir

Texnik xizmat ko‘rsatish ma’lumotlari ish buyurtmalari, sensor signallari, aktivlar tarixi, xarajatlar va texnik mutaxassislarning bilimlarini bog‘laydi. To‘g‘ri ishlatilganda, u rejalashtirish,...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...