Product Overview

The KM2002-0004 (KM 2002-0004) is a high-density Bus Terminal module designed to bridge the gap between control logic and field-level actuators. Integrating 16 digital outputs into a compact 26.5 mm housing, this module provides 24 VDC at 0.5 A per channel, split across two 8-channel pluggable connectors. In industrial applications such as conveyor sorting systems, automated assembly stations, and high-node-count control panels, the KM2002-0004 is essential for driving ohmic, inductive, and lamp loads. By utilizing a 3-wire connection technology with integrated status LEDs, it offers superior diagnostic capabilities and simplified wiring for sensors and actuators, significantly reducing installation time and cabinet complexity compared to standard single-channel terminals.

Technical Configuration

The KM2002-0004 architecture is optimized for rapid deployment and high reliability. Unlike standard terminals, the KM series uses a pluggable wiring level, allowing for pre-wired harnesses to be connected or disconnected instantly. The "0004" variant specifically features a 3-wire connection interface, which facilitates the direct connection of actuators by providing signal, 24V, and 0V paths at the terminal level. The module is short-circuit proof with a peak current limit of < 2 A and provides 500 V of electrical isolation between the K-bus and the field potential. Its binary control signals are transferred with minimal delay, and the integrated reverse voltage protection ensures the longevity of the module even in the event of wiring errors during commissioning.

Technical Specifications

Attribute Specification Details
Model KM2002-0004
Brand BECKHOFF
Origin Germany
Number of Outputs 16 (2 x 8 channels)
Nominal Voltage 24 VDC
Max. Output Current 0.5 A per channel (Short-circuit proof)
Connection Tech 3-wire pluggable connector with LEDs
Load Types Ohmic, Inductive, Lamp load
Electrical Isolation 500 V (K-bus / Field potential)
Current Consumption Typ. 5 mA (K-bus)
Bit Width 16 outputs in process image
Dimensions (W x H x D) 26.5 mm x 100 mm x 71 mm
Operating Temperature 0 to +55 deg C
Weight approx. 110 g (with 3-pin connector)
Shipping Weight 2.0 kg

Technical FAQs

What are the specific advantages of the -0004 variant over the -0000 base model?

While the KM2002-0000 is the bare module without connectors, the KM2002-0004 includes the 3-wire pluggable connectors and integrated LEDs. The 3-wire system is particularly beneficial for actuators that require a local power supply, as it eliminates the need for external distribution blocks.

Does this module require a power feed terminal?

The KM2002-0004 draws its internal logic power (5 mA) from the K-bus. However, the field power for the 16 outputs must be supplied to the module via the external pluggable connectors. Ensure your 24 VDC field power supply can handle the potential 8 A total load (16 channels x 0.5 A).

Can the KM2002-0004 drive inductive loads like solenoid valves?

Yes, the module is rated for inductive loads with a maximum breaking energy of < 150 mJ per channel. For highly inductive loads or high-frequency switching, it is still recommended to use external flyback diodes to protect the output circuitry and extend the module's lifespan.


Engineering & Installation Guide

Pluggable Connector Maintenance:

The KM2002-0004 utilizes a specific plug-in technology. When installing or removing the connectors, ensure the DIN rail power is disconnected to prevent arcing on the contact pins. Use the integrated locking mechanism on the 35 mm DIN rail to prevent the module from shifting, which could cause intermittent contact on the K-bus.

Wiring and Cross-Section Management:

The terminal supports stranded and solid wire with a cross-section of 0.08 to 1.5 mm². For optimal signal integrity and vibration resistance, a stripping length of 8 mm is required. In high-vibration environments, using ferrules is recommended to prevent wire splaying and potential short circuits between the high-density pins.

Thermal Considerations for High-Density I/O:

When all 16 channels are active at the maximum 0.5 A load, the module generates localized heat. Ensure a minimum vertical clearance of 30 mm is maintained above and below the Bus Terminal segment to allow for natural convection. If the ambient temperature in the cabinet consistently exceeds 45 deg C, consider active cooling or spacing the KM modules with passive end caps to ensure stable operation.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...