1 trong số 1

060B017291 Differential Pressure Switch with Thermal Time Relay

060B017291 Differential Pressure Switch with Thermal Time Relay

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 060B017291

  • Country of origin:Hoa Kỳ

  • Product Type: Differential Pressure Switch

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The 060B017291 (060B017291) is a high-precision differential pressure switch specifically engineered for the protection of refrigeration compressors and large-scale industrial machinery against low lubricating oil pressure. Serving as the official direct replacement for the legacy 060B017266, this unit integrates a critical thermal time relay that prevents "nuisance tripping" during the initial start-up phase or momentary pressure fluctuations. In critical sectors such as power generation, marine propulsion, and large-scale HVAC, the 060B017291 monitors the differential between the oil pump discharge pressure and the crankcase pressure. By ensuring that a safe oil pressure is maintained after a predetermined time delay, it acts as a primary safety guard against catastrophic mechanical failure and costly equipment downtime.

Technical Configuration

The hardware architecture of the 060B017291 is centered around a robust bellows system designed for maximum durability, capable of withstanding test pressures up to 22 bar (319 psig). The unit comes with a factory-set differential of 0.65 bar (9 psig), providing an optimized balance between safety and operational stability. The defining feature of this model is the integrated thermal time relay; this component introduces a necessary delay before the switch activates the safety circuit, allowing the oil pump to build sufficient pressure during start-up. The enclosure is rated IP20, suitable for installation within protected control cabinets or machinery housings. Designed for high-temperature resilience, the bellows can handle temperatures up to 100 deg C, while the ambient operating environment should be maintained at or below 60 deg C.

Technical Specifications

Feature Specification
Model 060B017291
Brand DANFOSS
Type Differential Pressure Switch (MP Series)
Factory Setting 0.65 bar (9 psig)
Max. Test Pressure (Pe) 22 bar (319 psig)
Bellows Max Temp 100 deg C / 212 deg F
Max. Ambient Temp 60 deg C
Control Element Thermal Time Relay
Enclosure Rating IP20
Legacy Replacement 060B017266
Shipping Weight 2.0 kg

Technical FAQs

Can I use the 060B017291 to replace my old 060B017266 unit?

Yes. The 060B017291 is the officially designated replacement for the 060B017266. It maintains the same form factor and technical parameters, ensuring a seamless drop-in installation without requiring modification to your existing piping or electrical logic.

What is the function of the thermal time relay in this switch?

The thermal time relay acts as a safety delay. When the compressor starts, the oil pressure is initially zero. The relay allows the system to run for a specific duration (the "time delay") to reach operating pressure. If the pressure fails to rise above the 0.65 bar setpoint before the relay times out, the switch trips the safety circuit to stop the machine.

Is it possible to adjust the 0.65 bar factory setting?

While the unit is factory-calibrated to 0.65 bar for standard compressor protection, minor adjustments may be possible depending on the specific application requirements. However, for most industrial oil lubrication systems, the 0.65 bar setpoint is the industry standard for optimal protection.

Why is the bellows temperature rating higher than the ambient rating?

The bellows are in direct contact with the process medium (e.g., hot lubricating oil), which can reach significantly higher temperatures than the surrounding air. The 100 deg C rating ensures the physical sensor element does not degrade when monitoring hot oil circuits.


Engineering & Installation Guide

  • Pulsation Dampening: When connecting the pressure switch to high-speed reciprocating compressors, it is recommended to use capillary tubes or pulsation dampers. This minimizes the mechanical vibration and pressure pulses reaching the bellows, preventing premature wear and ensuring the thermal relay operates based on stable average pressure values.

  • Electrical Wiring and Reset Logic: The safety circuit should be wired so that once the thermal relay trips, the compressor cannot restart automatically. Manual intervention should be required to reset the switch after investigating the cause of the low oil pressure. Ensure the supply voltage to the thermal relay matches the technical requirements to prevent coil burnout.

  • Mounting and Orientation: To ensure the longevity of the IP20 enclosure and internal components, mount the unit in a vibration-dampened position. Avoid areas with high humidity or chemical vapors that could affect the thermal relay's timing accuracy. Ensure the pressure connections are leak-tested to the 22 bar maximum to prevent environmental contamination.

 

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Bạc
Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...