Providing stabilized backplane logic power, the ABB DSSR122 functions as a high-capacity power supply module within the legacy Advant Master (Advant OCS) control system architecture. This module is engineered to accept a primary input range of 18V to 30V DC and convert it into a highly regulated 5V DC output rated at up to 40A. Built to withstand the electrical rigors of heavy industrial processes, the hardware delivers consistent, low-ripple power directly to the rack backplane to ensure continuous operation of processing units and communication interfaces.

Key Features

  • High Current Output: Delivers continuous 5V DC logic power at 40A to support dense multi-module configurations.
  • Wide DC Input Tolerance: Operates reliably across a fluctuating 18V to 30V DC input window, mitigating standard main-line voltage drops.
  • System Integration: Native mechanical and electrical compatibility with the ABB Advant Controller rack assemblies.
  • Rugged Enclosure: Industrial-grade metal housing designed for effective passive heat dissipation and structural protection.

Applications

  • ABB Advant Controller 410 (AC410) and Advant Controller 450 (AC450) process control stations.
  • Centralized cabinet installations requiring high-amperage 5V DC logic feeds.
  • Continuous process industries including paper mills, power generation, and chemical refinement plants.

Technical Specifications

Parameter Specification Value
Manufacturer ABB
Model Number DSSR122
Control Series Advant Master (Advant OCS)
Product Type Power Supply Unit
Input Voltage Range 18 - 30 V DC
Output Voltage 5 V DC
Output Current 40 A
Lifecycle Status Phase-Out / Legacy Spare Part
Commodity Code 85044095
Weight 2.40 kg
Dimensions (W x H x D) 102 mm x 152 mm x 279 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The DSSR122 acts as a direct-replacement power assembly. Ensure that physical backplane guides and dynamic sub-rack keying elements are aligned correctly with the unit chassis prior to insertion to prevent guide-pin damage on older OCS backplanes.

Application Pitfalls & Engineering Notes

Under a full 40A load, backplane contact resistance must be minimized. Oxidation on aging rack connectors can cause high-resistance points, leading to local voltage drops and thermal stress. Clean the backplane contacts with approved non-residue contact cleaners during standard maintenance cycles.

Commissioning & Wiring Tips

To accommodate the primary input current draw under peak startup conditions, ensure that the feeding 24V DC cabling is correctly dimensioned to prevent transient voltage sags. Use multi-strand copper conductors with correct ferrule terminations at the terminal block.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all primary and secondary DC supply sources before attempting mechanical installation or removal of this unit. High-current arcing hazard exists at the backplane interfaces when mounting under live electrical loads.

1

Inspect the card-edge backplane connectors on the DSSR122 for bent contacts, debris, or dust accumulation.

2

Align the module carefully with the sub-rack card guides, pushing the assembly firmly into place until the front locking mechanism is fully engaged.

3

Connect the input wires to the designated primary power terminals, verifying correct polarity (18-30V DC input).

4

Energize the primary source and measure output logic levels at the terminal monitoring points to verify stable 5V DC delivery.

What is the primary output rating of the DSSR122 unit?

The module delivers a stabilized 5V DC output with a maximum current rating of 40A, designed to supply logic power to the rack backplane.

What is the acceptable DC input voltage range?

The DSSR122 operates with a wide primary input range between 18V DC and 30V DC, allowing for stable operations during standard industrial supply fluctuations.

Does the DSSR122 require forced-air cooling in the panel?

The module utilizes natural convection cooling. However, users must maintain adequate vertical clearance inside the electrical cabinet to prevent excessive heat buildup under heavy loads.

Can this unit be hot-swapped while the system is under load?

No. Hot-swapping is not recommended due to high-current arcing hazards at the system backplane connectors. The primary supply must be fully de-energized before mounting or extracting.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Thụy Điển

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...