1 trong số 4

ABB PM865K01 3BSE031151R1 AC 800M High Integrity Processor Unit

ABB PM865K01 3BSE031151R1 AC 800M High Integrity Processor Unit

Only 6 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: PM865K01 3BSE031151R1

  • Country of origin:Thụy Điển

  • Product Type: Processor Unit

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 119 mm x 186 mm x 135 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

The ABB PM865K01 (Product ID: 3BSE031151R1) is a high-integrity central processing unit package engineered for the AC 800M hardware platform. It is certified for use in safety-critical applications up to Safety Integrity Level 3 (SIL3) in accordance with IEC 61508. Operating at 96MHz with 32MB of onboard memory, this processor unit serves as a highly robust control solution capable of running both non-SIL and SIL-classified applications simultaneously when deployed within an AC 800M High Integrity controller configuration.

The PM865K01 provides advanced internal diagnostics, enhanced oscillator supervision, and integrated double over-voltage protection on internal voltages. To comply with strict international safety standards, the module utilizes a dedicated monitoring architecture that requires configuration according to the official ABB Safety Manual. It facilitates expansive industrial connectivity through its built-in electrical and optical ModuleBus interfaces, alongside dual RJ45 Ethernet ports for highly available control network communications.

Features

  • Safety Integrity Level Certification: Fully qualified for SIL3 safety-critical installations when configured with an SM811 safety module.
  • High-Performance Architecture: Equipped with a 96MHz microprocessor and 32MB of robust system and user RAM.
  • Advanced Diagnostics: Built-in hardware-driven double inverted memory handling for real-time bit error detection without cycle delay.
  • Electrical Safety: Integrates double over-voltage protection on internal supply lines and enhanced system watchdog timers.
  • Flexible Communication Expansion: Built-in CEX-Bus interface allows for step-by-step expansion using various fieldbus protocols.
  • Bumpless Redundancy: Supports hot stand-by processor redundancy via an RCU Link, enabling fault changeover in less than 10 ms.
  • Robust Mechanics: Features a slide-and-lock mechanism for secure DIN-rail installation and direct chassis grounding.

Applications

  • Safety Instrumented Systems (SIS): Emergency Shutdown (ESD) and fire and gas protection systems.
  • Distributed Control Systems (DCS): Continuous process control loop operations across large-scale industrial plants.
  • High-Integrity Automation: Critical infrastructure management requiring simultaneous execution of control and safety functions.
  • Boiler and Burner Management Systems (BMS): Safe sequencing and combustion monitoring for heavy utility boilers.

Ordering Information

The PM865K01 product package includes the following verified hardware components:

Item / Model Product ID Component Description
PM865 3BSE031151R1 Safety CPU, 96MHz, 32MB (No license included)
TP830 Baseplate Unit
TB850 CEX-bus Terminator (Male)
TB807 ModuleBus Terminator Plug
TB852 RCU-Link Terminator Plug
4943013-6 Lithium battery for memory backup

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID 3BSE031151R1
ABB Type Designation PM865K01
Processor Speed 96MHz
Onboard Memory 32MB
Product Net Width 119 mm
Product Net Height 186 mm
Product Net Depth / Length 135 mm
Product Net Weight 1.2 kg
Battery Type Portable Lithium (9 g weight)
Protection Class IP20
Maximum Operating Temperature 40 degC (ambient outside enclosure)
RoHS Compliance Not RoHS 2 2011/65/EU compliant (Spare part rules apply)

Connections/Interfaces

CN1 and CN2 Control Network Ports

Connector Pin Function Description
1 TD+ Transmit Data (plus)
2 TD- Transmit Data (minus)
3 RD+ Receive Data (plus)
4-5 Not used Leave disconnected
6 RD- Receive Data (minus)
7-8 Not used Leave disconnected
Housing Shield Chassis ground connection

COM3 Serial Port (RS-232C with Modem Control)

Connector Pin Function Description
1 RTS Request To Send
2 DTR Data Terminal Ready
3 TD Transmit Data
4 0V Signal ground
5 0V Signal ground
6 RD Receive Data
7 DCD Data Carrier Detect
8 CTS Clear To Send
Housing Shield Chassis ground connection

Installation Guidelines

  • DIN-Rail Mounting: Install horizontally onto a top-hat type TS 35/7.5 DIN-rail. Rotate the baseplate locking device counter-clockwise to the OPEN position before clipping onto the rail.
  • Slide & Interconnect: Once hooked over the upper edge of the rail, move the locking device to the SLIDE position. Slide the module sideways to align carefully and mate its baseplate connectors with adjacent units. Ensure strict pin alignment to prevent physical structural damage.
  • Grounding: Lock the unit into place by turning the locking screw clockwise to the LOCKED position. This engages the internal grounding mechanism firmly against the unpainted metal surface of the DIN-rail.
  • Power Supply Wiring: Connect the 24V DC lines into the screw terminals of the baseplate. To suppress unexpected errors from monitoring links when a single supply is utilized, jump input terminals SA and SB on the unit directly to +24 V DC.
  • Battery Handling: Do not plug the internal lithium battery into its respective slot until the controller has fully powered up normally and the active battery LED begins to flash. Inserting the battery into a powered-down module will instantly exhaust its cell power.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB PM865K01 3BSE031151R1 AC 800M High Integrity Processor Unit

Can the local electrical ModuleBus be utilized in a redundant processor layout?

No. When running in a redundant CPU configuration, the electrical ModuleBus built into the baseplate cannot be used. All S800 I/O connections must interface through the optical ModuleBus via cluster modems.

What is the purpose of the TB852 plug included in the PM865K01 kit?

The TB852 is an RCU Link Termination plug. It must be installed into the RCU Link connector whenever the processor module is deployed in a single (non-redundant) controller configuration.

Why shouldn't I insert the backup battery before powering up the processor?

If the backup battery is placed into the holder before a normal external 24V DC supply is turned on, the CPU memory circuits will immediately begin draining the battery, significantly limiting its field lifespan.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng
Country of origin
Thụy Điển
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...