Product Overview

The EL1859 (EL1859) is a high-density (HD) EtherCAT terminal that integrates 8 digital inputs and 8 digital outputs into a single, space-saving 12 mm wide module. Designed for versatile industrial applications, this "combi" terminal supports 24 V DC signals and is optimized for efficient signal processing in compact control cabinets. By providing a high channel density, the EL1859 minimizes the footprint of I/O assemblies while maintaining the deterministic, high-speed communication performance of the EtherCAT network. It is ideal for machine control systems requiring a balance of monitoring and actuation capabilities, including sensor feedback collection and small actuator control for conveyors, packaging, and assembly lines.

Technical Configuration

The EL1859 features a 1-wire connection technology, significantly reducing the amount of field wiring required. The input stages comply with EN 61131-2 (type 1/3), ensuring robust compatibility with a wide range of standard sensors. The output channels are capable of driving ohmic, inductive, and lamp loads with a maximum current of 0.5 A per channel, complemented by integrated reverse voltage protection to safeguard the hardware against wiring errors or transient back-EMF from inductive loads. The module utilizes a high-density (HD) polycarbonate housing, supporting side-by-side mounting via a double slot and key connection, which ensures mechanical stability on standard 35 mm DIN rails.

Technical Specifications

Feature Specification
Model EL1859
Brand Beckhoff
Channels 8 Digital Inputs / 8 Digital Outputs
Nominal Voltage 24 V DC
Output Current 0.5 A per channel
Input Filter 3.0 ms
Weight 65 g
Dimensions 12 mm x 100 mm x 68 mm
Operating Temp 0 deg C to 55 deg C
Protection Class IP20

FAQs

How does the HD (High Density) housing differ from standard terminals?

The HD housing allows for a higher number of I/O points within the same 12 mm width by optimizing the terminal layout and connection density, perfect for applications where control cabinet space is limited.

Is it necessary to set an address for the EL1859 during installation?

No. Like all standard Beckhoff EtherCAT terminals, the EL1859 is auto-configured by the EtherCAT master; there are no manual address or configuration switches required.

Can I drive inductive loads directly with the output channels?

Yes, the outputs are designed to handle inductive loads. However, ensure that the energy stored in the inductive load does not exceed the specified breaking energy of < 150 mJ per channel to prevent damage to the output switching transistors.

What is the benefit of the 1-wire connection technology?

The 1-wire connection reduces cabling complexity by consolidating the signal path, which is particularly beneficial for high-density I/O configurations, leading to faster installation times and reduced cabinet wiring clutter.

Installation Guidelines and Best Practices

  • Wiring Technique: For solid conductors, you can utilize the direct plug-in technique. For fine-stranded conductors or wires with ferrules, use a small screwdriver to actuate the spring terminals to ensure a reliable, gas-tight connection.

  • Thermal Management: While the terminal is compact, maintain proper airflow within the cabinet. In dense I/O assemblies where all channels are fully loaded, ensure the ambient temperature does not exceed 55 deg C to maintain the specified lifespan of the electronic components.

  • EMC Considerations: Although the terminal complies with EN 61000-6-2/6-4, always route digital I/O signal cables away from high-power motor drive cables or high-voltage AC lines to prevent induced noise from causing false signal triggers or output jitter.

 

Key Features:

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng
Country of origin
Đức
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...