1 trong số 1

Beckhoff ER2624-0002 EtherCAT Box 4-Channel Relay Output Module

Beckhoff ER2624-0002 EtherCAT Box 4-Channel Relay Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ER2624-0002

  • Country of origin:Đức

  • Product Type: EtherCAT Box Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Functioning as a ruggedized distributed I/O solution, the Beckhoff ER2624-0002 industrial Ethernet module coordinates digital signal relaying directly in harsh field environments. Encased in a robust zinc die-cast housing, this IP67-rated EtherCAT Box provides four potential-free relay make contacts (normally open) designed to switch electromechanical loads up to 2 A DC or 0.5 A AC. By implementing direct fieldbus control without an electrical control cabinet, this module shortens cable runs, minimizes signal degradation, and optimizes system layout in decentralised automation topologies.

Features

  • Potential-Free Switching: Offers complete electrical isolation of 500 V between the control electronics and the load circuits.
  • Optimized Relay Outputs: Four independent make (NO) contacts capable of switching ohmic, inductive, and lamp loads.
  • Rugged Die-Cast Enclosure: Heavy-duty zinc housing provides superior mechanical resistance and high-grade electromagnetic shielding.
  • High-Durability Design: Engineered for extreme service life, achieving up to 100,000,000 mechanical operating cycles.
  • Direct Field Connection: Integrated dual M8 shielded screw-type connectors for the EtherCAT bus interface alongside standard M12 output interfaces.

Applications

  • Decentralized control of low-voltage solenoids, contactors, and pneumatic valves.
  • Wet processing areas, machine tools, and manufacturing lines requiring IP65/66/67 protection ratings.
  • Test benches and automated assembly systems utilizing distributed switching structures.
  • On-machine indicator lighting and audible alarm signaling.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model / Part Number ER2624-0002
Fieldbus Protocol EtherCAT
Number of Outputs 4 x make contacts (potential-free)
Rated Load Voltage 25 V AC / 30 V DC
Ohmic Switching Current 0.5 A AC / 2 A DC
Minimum Permitted Load 10 microamps at 10 mV DC
Bus Interface 2 x M8 socket, shielded, screw type
Output Connections M12 x 1, 5-pin, a-coded
Nominal Output Voltage 24 V DC (-15% / +20%)
Current Consumption (from Us) 120 mA
Operating Cycles (Mechanical) 1 x 10^8 minimum
Operating Cycles (Electrical) 2 x 10^5 minimum (at 1 A / 30 V DC)
Electrical Isolation 500 V
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating / Storage Temperature -25 to +60 degC / -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Net Weight 265 g
Shipping Weight (Calculated) 2.0 kg
Approvals CE, UL

Connections and Interfaces

Interface Location Connector Type Pin Assignment / Signal
EtherCAT Input/Output 2 x M8 socket, 4-pin, shielded Tx+, Rx+, Tx-, Rx- (standard EtherCAT transmission lines)
Output Channels (1 to 4) 4 x M12 female, 5-pin, a-coded Pin 1 & Pin 2: Relay Contact; Pin 5: Functional Earth (FE)
Control Voltage Feed 1 x M8 male, 4-pin Feed: Us (24 V DC system/sensor power), Up (peripheral/load power)
Downstream Power Link 1 x M8 female, 4-pin Daisy-chain distribution of Us and Up voltages to next EtherCAT Box

Empirical Engineering Insights

Alternative Models & Compatibility

The ER2624-0002 features a zinc die-cast housing designed to offer superior mechanical resistance and optimal shielding compared to its plastic-clad equivalent, the EP2624-0002. Both models share identical electronic components and pin assignments, allowing direct drop-in replacement within the TwinCAT System Manager software environment without requiring changes to the existing XML device description files.

Application Pitfalls & Engineering Notes

When switching inductive loads (such as DC contactors, solenoid valves, or brake coils), users must integrate external protective circuits (e.g., recovery diodes for DC loads or RC snubbers for AC loads) directly parallel to the load. Failing to suppress counter-electromotive force (back-EMF) transient spikes will cause contact arcing, drastically reducing the electrical service life of the internal miniature relays below the rated 200,000 cycles.

Commissioning & Wiring Tips

Ensure that both the Us (system and sensor power) and Up (peripheral voltage) lines are correctly stabilized. Even though the relays are potential-free, the internal logic requires a continuous 120 mA draw from the Us bus. For systems running long daisy-chained power lines, check for voltage drops; any dip below 20.4 V DC (24 V DC -15%) will trigger communication disruptions and cause erratic relay coil actuation.

Installation Guidelines

CRITICAL WARNING: De-energize all primary, peripheral, and load power supplies prior to physical installation, connector insertion, or configuration changes. Contact with high-voltage lines can cause severe electrical shock, equipment damage, or system-wide communication failure.
1
Position the module on a flat, grounded mounting plate or machine frame using the integrated mounting flanges. Secure with two M4 screws tightened to the specified torque limit.
2
Ensure direct metallic contact between the mounting plate and the module body to establish proper Functional Earth (FE) grounding paths.
3
Connect the incoming EtherCAT bus cable to the top-side M8 input socket, and route the output line to the subsequent box if using a daisy-chain topology. Tighten the collar to ensure IP67 sealing.
4
Plug the M12 actuator cables into the appropriate output ports (Channels 1 through 4), ensuring proper alignment of the a-coded keyway.
5
Verify that all unused M8 and M12 ports are sealed with approved protective caps to preserve IP67 fluid ingress protection ratings.

What is the key structural difference between the ER2624-0002 and the EP2624-0002?

The ER2624-0002 is housed in a robust zinc die-cast metal enclosure for superior mechanical strength and shielding, while the EP2624-0002 features a lightweight plastic housing. Their electrical capabilities, software definitions, and pin configurations are identical.

Does the ER2624-0002 require external arc suppression for inductive loads?

Yes. When controlling inductive loads like solenoid valves or motor contactors, you must install an external free-wheeling diode or RC snubber across the load. Unsuppressed inductive spikes will damage the internal mechanical relay contacts.

Can I operate this EtherCAT Box without a separate peripheral power feed (Up)?

The module requires a stable system power feed (Us) at 120 mA to maintain its internal logic and EtherCAT communication. The output circuits are potential-free relay contacts; any load-side voltages must be supplied separately to the relay pins.

What protection class is achieved by the ER2624-0002?

It achieves IP65, IP66, and IP67 protection ratings, provided that all mated connectors are fully tightened and any unused M8 or M12 interfaces are fitted with sealed protective caps.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...