1 trong số 1

C9900-E301 BECKHOFF 2-Port RS232 PCIe Interface Module

C9900-E301 BECKHOFF 2-Port RS232 PCIe Interface Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: C9900-E301

  • Country of origin:Đức

  • Product Type: RS232 PCIe module

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The C9900-E301 (C9900-E301) is a high-performance industrial PCIe expansion module designed to provide dual-channel serial communication for Beckhoff Industrial PCs (IPCs). This module is engineered to expand the connectivity of control systems in sectors such as semiconductor manufacturing, advanced robotics, and legacy system integration. Supporting high-speed transmission rates up to 921,600 bps, the C9900-E301 allows IPCs to interface reliably with specialized sensors, barcode readers, and serial field devices. By utilizing a compact internal structure with ix type B sockets, it maintains a high-density footprint within the IPC chassis, ensuring robust data throughput and signal integrity for critical serial automation tasks.

Technical Configuration

The C9900-E301 utilizes the PCIe (PCI Express) bus architecture to ensure low-latency communication between the CPU and the serial ports. Unlike standard serial cards, this industrial module features two specialized ix type B sockets rather than traditional D-sub connectors directly on the bracket. This design prioritizes vibration resistance and space efficiency. To interface with standard serial hardware, the module must be used with two C9900-K920 adapter cables, which convert the ix type B connection to a standard 9-pin D-sub (RS232) interface. The hardware supports full-duplex transmission and is fully compatible with Windows-based industrial operating systems and TwinCAT real-time communication protocols.

Technical Specifications

Attribute Specification Details
Model C9900-E301
Brand BECKHOFF
Origin Germany
Interface Type PCIe (PCI Express)
Number of Ports 2 x RS232
Transmission Rate Up to 921,600 bps
Connection Type 2 x sockets ix type B
Required Accessory 2 x C9900-K920 adapter cables
Form Factor Low-profile PCIe plug-in card
Operating Temp 0 to +55 deg C
Protection Rating IP20
Weight approx. 120 g
Shipping Weight 2.0 kg

Technical FAQs

Is the C9900-E301 compatible with standard commercial PCs?

While the C9900-E301 uses a standard PCIe slot, it is specifically validated and designed for use within Beckhoff Industrial PC environments. Optimal performance and driver support are guaranteed when integrated into CX or C-series IPCs.

Why does this module use ix type B connectors instead of D-sub 9?

The ix type B connector is an industrial-grade interface that is significantly smaller and more rugged than a standard D-sub connector. This allows Beckhoff to provide dual-port functionality on a single-slot bracket while ensuring a secure, click-lock connection that is resistant to high-vibration industrial environments.

Does the module come with the necessary adapter cables?

No, the C9900-E301 requires the separate purchase of two C9900-K920 cables to convert the internal ix type B sockets to the industry-standard D-sub 9-pin RS232 format.


Engineering & Installation Guide

Cable Management and Connectivity:

When installing the C9900-E301, ensure the C9900-K920 adapter cables are properly seated until the "click" mechanism of the ix type B connector engages. This mechanical lock is vital in preventing signal loss due to vibration. Route the D-sub ends of the cables away from high-voltage AC lines or frequency inverters to minimize electromagnetic interference on the RS232 signal path.

PCIe Slot Installation and ESD Safety:

This module is a sensitive electronic component. Always wear an ESD (Electrostatic Discharge) wrist strap and ensure the IPC is fully powered down before opening the chassis. Insert the card into a vacant PCIe slot and secure the bracket screw to ensure a proper chassis ground connection. After installation, verify the port assignments in the BIOS or Device Manager to ensure the system has correctly enumerated the two new COM ports.

Software Integration (TwinCAT/Windows):

In most Beckhoff IPC environments, the RS232 ports will be recognized as standard COM ports. For real-time serial communication within TwinCAT, use the "Serial Communication" library. Ensure the baud rate, parity, and stop bits are configured to match your peripheral device; the C9900-E301 can handle high-speed rates up to 921.6 kbps, which may require high-quality shielded cabling for the external D-sub run to maintain data integrity.

 

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Xanh lá cây
Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...