  • Manufacturer: Mitsubishi Electric

  • Product No.: A2ACPUP21

  • Country of origin:Hoa Kỳ

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 250 mm x 110 mm x 130 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Integrating advanced optical network connectivity directly into the processor architecture, the Mitsubishi Electric A2ACPUP21 serves as a specialized central processing unit for the legacy MELSEC A Series PLC platform. This module combines the processing performance of an A2ACPU core with an integrated MELSECNET optical data link interface, providing high-speed peer-to-peer and master-sub station communications across fiber-optic loops. By consolidating control execution and optical networking capabilities onto a single slot, this CPU unit optimizes backplane space efficiency and minimizes communication latency within distributed control topologies.

Key Features

  • Integrated Optical Interface: Eliminates the need for a separate network module by building MELSECNET optical loop capabilities directly into the CPU.
  • Advanced Instruction Processing: High-speed execution of logic, sequence, and data manipulation instructions native to the A-Series controller range.
  • Noise-Immune Communication: Fiber-optic transmission path provides absolute immunity to electromagnetic interference (EMI) and radio frequency interference (RFI) in harsh environments.
  • Dual-Loop Redundancy: Supports optical loop configurations to ensure uninterrupted communications in the event of a single cable breakage.

Applications

  • Automotive assembly line synchronization over distributed networks.
  • Municipal water treatment facilities requiring isolated, long-distance inter-station communication.
  • Heavy metallurgical processing plants with high EMI/RFI electrical noise profiles.
  • Large-scale material handling and conveyor network control architectures.

Technical Specifications

Manufacturer Mitsubishi Electric
Model Number A2ACPUP21
Product Line MELSEC A Series
Module Type Data Link PLC CPU Unit
Network Interface MELSECNET Optical Fiber Loop (P21 Type)
Medium Link Connection Dual-core optical fiber cable (SI/GI spec)
Operating Temperature 0 to 55 degC
Country of Origin Japan
Shipping Weight (Calculated) 2.0 kg (4.41 lbs)
Package Dimensions (Calculated) 250 mm x 110 mm x 130 mm

Optical Connections and Interfaces

Port / Interface Function / Cable Assignment
TX Port Optical fiber transmitter (outbound loop segment)
RX Port Optical fiber receiver (inbound loop segment)
RS-232C Port Programming, debugging, and peripheral connectivity interface

Empirical Engineering Insights

Alternative Models & Compatibility

The A2ACPUP21 integrates functions equivalent to an A2ACPU combined with an AJ71LP21 optical data link card. When replacing older non-integrated configurations, ensure your program address allocations accommodate the integrated link parameters. Be aware that the optical transceiver circuits are optimized for SI-type (plastic-clad) or GI-type (glass) fiber optic cables; matching the correct cable attenuation characteristics is critical for link stability.

Application Pitfalls & Engineering Notes

A common field issue with legacy MELSECNET optical modules is signal degradation caused by micro-bends or dust accumulation inside the fiber ports. Ensure you maintain the manufacturer's specified minimum bend radius for the fiber cables inside the wiring duct. Always use standard protective dust caps on unused RX/TX channels to prevent contamination of the optical transceiver lenses.

Commissioning & Wiring Tips

During initial commissioning, verify the station number and network settings using the hardware rotary switches located on the front faceplate of the CPU prior to powering up the chassis. If the "L.ERR" (Link Error) LED activates, verify that the TX of the master station is connected directly to the RX of the local station. Interchanging the TX/RX fiber connections is the leading cause of initial handshake failures in redundant optical loop configurations.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all AC/DC power sources feeding the PLC backplane chassis before installing, removing, or adjusting the CPU unit. Failure to completely de-energize the system can result in electrical shock, hardware destruction, or erratic control system behaviors that could lead to machinery damage.

1
Ensure the main chassis base unit is securely mounted and the system power supply module is fully de-energized.
2
Align the bottom retention hook of the A2ACPUP21 CPU module with the base unit guide slot, then pivot the module firmly into the backplane connector.
3
Secure the module retention screw at the top of the unit to ensure mechanical stability against industrial vibrations.
4
Connect the dual optical fiber loops to the RX and TX ports, ensuring proper latching alignment, and secure the peripheral RS-232C programming line.

What is the primary technical advantage of using the A2ACPUP21 unit?

The module consolidates a standard MELSEC A2ACPU processor and a MELSECNET/II optical network transceiver onto a single module footprint, reducing backplane slot usage and streamlining configuration.

Which fiber-optic cable types are compatible with the integrated P21 interface?

It is designed for standard SI-type (silica glass core with plastic cladding) or GI-type (graded index glass) multi-mode optical cables, depending on the distance requirements of your network segment.

What diagnostic step should I take if the L.ERR LED lights up on commissioning?

Verify the physical fiber loop path routing. Ensure that the TX port of the upstream station is connected to the RX port of this unit, and verify that the station number switches on the front panel are set to unique values.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...