1 trong số 1

VFD1320CP43B-21 DELTA CP2000 Series Fan/Pump Vector Control Drive

VFD1320CP43B-21 DELTA CP2000 Series Fan/Pump Vector Control Drive

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: VFD1320CP43B-21

  • Country of origin:Hoa Kỳ

  • Product Type: Fan/Pump Vector Control Drive

  • Payment: T/T, Western Union

  • Weight: 68000g

  • Dimensions: 14.57in (W) X 28.18in (H) X 11.81in (D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The VFD1320CP43B-21 (VFD1320CP43B21) is a high-capacity 132 kW (175 HP) Variable Frequency Drive specifically engineered for energy-intensive fluid technology applications. As part of Delta’s specialized CP2000 series, this drive utilizes advanced sensorless vector control to optimize the performance of centrifugal fans and pumps in large-scale HVAC systems, water treatment facilities, and industrial cooling towers. By implementing precise PID control and a multi-pump master/slave configuration, the VFD1320CP43B-21 significantly reduces energy consumption and mechanical stress during start-stop cycles, providing a critical safeguard against water hammer effects and system pressure surges.

Technical Configuration

The hardware architecture of the VFD1320CP43B-21 is optimized for high-power industrial environments, featuring a robust wall-mount design with NEMA 1/IP20 protection. The drive operates on a 460V 3-Phase input, delivering a steady 260 Amps to support heavy-duty motors. It incorporates a built-in BACnet communication protocol, making it natively compatible with Building Automation Systems (BAS). The internal logic includes a "Fire Mode" for emergency tunnel ventilation and "Sleep Mode" for pump energy savings, ensuring that the drive balances performance with rigorous safety and efficiency standards.

Technical Specifications

Parameter Specification
Model VFD1320CP43B-21
Brand Delta Electronics
Series CP2000
Motor Capacity 132 kW (175 HP)
Rated Current 260 Amps
Input Voltage 460V 3-Phase
Control Method Sensorless Vector Control (SVC) / V/f
Protection Level IP20 / NEMA 1
Installation Wall Mount
Operating Temp -10 to 50 Celsius
Dimensions 370 x 715.8 x 300 mm (14.57 x 28.18 x 11.81 in)
Weight 66 kg
Shipping Weight 68 kg

Technical FAQs

How does the VFD1320CP43B-21 handle multi-pump control without an external PLC?

The CP2000 series features a built-in 10k step PLC and multi-pump control logic. It can manage up to 8 motors simultaneously through fixed-amount or fixed-time circulation control, balancing the runtime of each pump to extend the overall equipment lifecycle.

What is the "Fire Mode" and how does it affect drive protection?

When Fire Mode is activated via a digital input, the drive bypasses standard protective alarms (such as over-temperature) to ensure the fan continues running for smoke extraction or pressurization during an emergency, prioritizing human safety over hardware protection.

Can this drive be used in high-humidity water treatment environments?

While the drive is rated NEMA 1/IP20, it is designed for indoor cabinet installation. For high-humidity or corrosive environments typical of water treatment, it must be installed within a secondary enclosure with appropriate thermal management to prevent condensation on the internal PCBs.


Engineering & Installation Guide

  • Lifting and Mounting Safety: Given the 66 kg unit weight, always use the designated lifting eyelets located at the top of the chassis. Ensure the mounting surface is a non-combustible metal plate or reinforced concrete wall capable of supporting four times the drive's weight to prevent vibration-induced fatigue.

  • Thermal Displacement: This drive dissipates significant heat at a 260 Amp load. Maintain a minimum vertical clearance of 200 mm above and below the unit. If multiple drives are installed in one cabinet, use a "side-by-side" configuration only if derating factors are applied or if high-volume forced air cooling is present to maintain an ambient temperature below 40 Celsius.

  • Harmonic Mitigation: For a 132 kW motor, it is highly recommended to install a DC reactor (often built-in or optional) or an AC line reactor at the input. This reduces Total Harmonic Distortion (THD) and protects the drive's bridge rectifier from voltage spikes and line imbalances common in heavy industrial grids.

 

Key Features:

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...